03Fault

Voltronic inverter error 03

Battery voltage is too high

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Axpert MAX II TWIN

InverterFault

Also applies to:Axpert MAX II TWIN 8KWAxpert MAX II TWIN 11KWAxpert MAX II TWIN 12KWAxpert MAX II Duplex 8KWAxpert MAX II Duplex 11KWAxpert MAX II 8KWAxpert MAX II 11KWAxpert MAX 8K TWIN PV11K+46

What it means

Battery voltage is too high

Cause: Battery is over-charged.

How to fix it

Return to repair center.

Source: Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.55 · Axpert-MAXII-11K-TWIN-Off-grid-manual.pdf, p.47 · +57 more official manuals

What it means

BUS soft start time outFault code 03 shown on the display with the fault icon on: BUS soft start time out.

Cause: BUS soft start time out.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: InfiniSolar-WP-LV-12KW-Premium-manual.pdf, p.52

InfiniSolar 10KW

InverterFault

Also applies to:InfiniSolar 15KWInfiniSolar Super 4KWInfiniSolar Plus 5KWInfiniSolar TX-PA 30KW

What it means

BUS soft start time outFault code 03 shown on the display with the fault icon on: BUS soft start time out.

Cause: Internal components failed.

How to fix it

Please contact your installer.

Source: InfiniSolar-10KW-manual-20191126.pdf, p.50 · InfiniSolar-15K-manual-20200313.pdf, p.51 · InfiniSolar-Super-4KW-manual.pdf, p.47 · +2 more official manuals

InfiniSolar E 5.5KW

InverterFault

What it means

DC bus voltage soft-start is time-outFault code 03 shown on the display with the fault icon on: DC bus voltage soft-start is time-out.

Cause: DC bus voltage soft-start is time-out.

How to fix it

  1. Disconnect AC circuit breaker first.
  2. Then, disconnect DC circuit breaker.
  3. Until LCD screen completely shuts down, turn on DC breaker first.
  4. It will show "No Utility" in LCD screen.
  5. Then, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If the error message still remains, please contact your installer.
  8. The internal temperature is higher than specified temperature.
  9. Leave inverter to cool down to room temperature.
  10. If the error message still remains, please contact your installer.
  11. Check if the open circuit voltage of PV modules is higher than 500VDC.
  12. If PV open circuit voltage is less than 500VDC and the error message remains, pelase contact your installer.
  13. Turn off the inverter.
  14. Then, restart the inverter.
  15. If the error message still remains, please contact your installer.
  16. The ground voltage is too high.
  17. Please disconnect AC breaker first and then DC breaker.
  18. Check if grounding is connected properly after LCD screen.

Source: InfiniSolarE-5.5KW-manual.pdf, p.43

InfiniSolar 2KW/3KW

InverterFault

Also applies to:InfiniSolar 2KWInfiniSolar 3KW

What it means

DC bust voltage soft-start is time-outFault code 03 shown on the display with the fault icon on: DC bust voltage soft-start is time-out.

Cause: DC bust voltage soft-start is time-out.

How to fix it

  1. Disconnect AC circuit breaker first. Then, disconnect DC circuit breaker
  2. Until LCD screen completely shuts down, turn on DC breaker first. It will show "No Utility" in LCD screen. Then, turn on AC breaker. After 300 seconds, the system will automatically connect to the grid
  3. If the error message still remains, please contact your installer.

Source: InfiniSolar-2KW3KW-manual.pdf, p.46

DC Converter 3KW

InverterFault

What it means

Output current is abnormalFault code 03 shown on the display with the fault icon on: Output current is abnormal..

Cause: Output current is abnormal.

How to fix it

  1. Restart the converter
  2. If the problem remains, please contact your installer.

Source: DC-converter-3KW-manual.pdf, p.20 · DC-converter-3KW-manual.pdf, p.21

ESS510

Energy storage systemFault

What it means

DC bus voltage soft-start is timeoutFault code 03 shown on the display with the fault icon on: DC bus voltage soft-start is timeout..

Cause: DC bus voltage soft-start is timeout.

How to fix it

  1. Disconnect AC circuit breaker first.
  2. Then, disconnect DC circuit breaker.
  3. Until LCD screen completely shuts down, turn on DC breaker first.
  4. It will show "No Utility" in LCD screen.
  5. Then, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If the error message still remains, please contact your installer.

Source: ESS510-manual.pdf, p.68

Also applies to:Galleon II 6KGalleon II 10KGalleon III 1KGalleon III 2KGalleon III 3KGiant Elite 1P/1P 6K-10KWinner Pro 1KVA-3KVAWinner Pro 6KVA+6

What it means

Bus underFault code 03 shown on the display; the UPS has detected a fault condition: Bus under.

Cause: Bus under.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: GalleonII-6-10K-Tower-RT-manual.pdf, p.29 · Galleon-III-Tower-Rack-1-3K-manual.pdf, p.31 · Giant-Elite-1P-1P_manual.pdf, p.26 · +5 more official manuals

Also applies to:Galleon X9 6K RTGalleon X9 10K RT

What it means

Bus UnderFault code 03 shown on the display; the UPS has detected a fault condition: Bus Under.

Cause: The internal converter failed, so the DC bus voltage is too low.

How to fix it

Contact the dealer to repair.

Source: Galleon-X9-6-10K-RT_manual.pdf, p.28

Also applies to:Giant Elite 3P/3P 10K-40KVA

What it means

Overload faultFault code 03 shown on the display; the UPS has detected a fault condition: Overload fault.

Cause: Overload fault.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: Giant-Elite-3P3P-manual.pdf, p.41

Frequently asked questions

What does error 03 mean on a Voltronic inverter?
It depends on the model — 48 devices use code 03. On the Axpert MAX II TWIN it means: Battery voltage is too high. The card for each model on this page gives its exact meaning and fix.
Is error 03 a fault or a warning?
03 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 03?
Return to repair center. The exact steps for each affected model are listed on this page.