This is the complete fault table for the Voltronic InfiniSolar V Inverter family — 20 codes shared by 5 model numbers, transcribed from the official manual. On Voltronic units, a fault code means the unit has cut its output and the red LED stays solid; a warning flashes the red LED while the unit keeps running.

Also coversInfiniSolar V 1KWInfiniSolar V 2KWInfiniSolar V 3KWInfiniSolar V 4KWInfiniSolar V 5KW

Last checked against the official manuals on July 27, 2026.

How to read the severity labels

  • Fault(16)output stops · red LED solid
  • Warning(4)unit keeps running · red LED flashing

Fault codes (16)output stops · red LED solid

01Fault

Fan locked.

Fault

Fault code 01 shown on the display with the fault icon on: Fan locked.

CauseFan fault.

Recommended fixReplace the fan.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

02Fault

Over temperature.

Fault

Fault code 02 shown on the display with the fault icon on: Over temperature.

CauseInternal temperature of inverter component is over 100°C.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

03Fault

Battery voltage is too high.

Fault

Fault code 03 shown on the display with the fault icon on: Battery voltage is too high.

CauseBattery is over-charged.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

04Fault

Battery voltage is too low.

Fault

Fault code 04 shown on the display with the fault icon on: Battery voltage is too low.

CauseBattery voltage is too low.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28

05Fault

Output short circuited.

Fault

Fault code 05 shown on the display with the fault icon on: Output short circuited.

CauseOutput short circuited.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

06Fault

Output voltage abnormal.

Fault

Fault code 06 shown on the display with the fault icon on: Output voltage abnormal.

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

07Fault

Over load time out.

Fault

Fault code 07 shown on the display with the fault icon on: Over load time out.

CauseOverload error. The inverter is overload 110% and time is up.

Recommended fixReduce the connected load by switching off some equipment.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

08Fault

Bus voltage is too high.

Fault

Fault code 08 shown on the display with the fault icon on: Bus voltage is too high.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

09Fault

Bus soft start failed.

Fault

Fault code 09 shown on the display with the fault icon on: Bus soft start failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

51Fault

Over current or surge.

Fault

Fault code 51 shown on the display with the fault icon on: Over current or surge.

CauseOver current or surge.

Recommended fixRestart the unit, if the error happens again, please return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

52Fault

Bus voltage is too low.

Fault

Fault code 52 shown on the display with the fault icon on: Bus voltage is too low.

CauseBus voltage is too low.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

53Fault

Inverter soft start failed.

Fault

Fault code 53 shown on the display with the fault icon on: Inverter soft start failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

55Fault

Over DC offset in AC output.

Fault

Fault code 55 shown on the display with the fault icon on: Over DC offset in AC output.

CauseOutput voltage is unbalanced.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

56Fault

Battery disconnected.

Fault

Fault code 56 shown on the display with the fault icon on: Battery disconnected.

CauseBattery is not connected well or fuse is burnt.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

57Fault

Current sensor failed.

Fault

Fault code 57 shown on the display with the fault icon on: Current sensor failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

58Fault

Output voltage is too low.

Fault

Fault code 58 shown on the display with the fault icon on: Output voltage is too low.

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28InfiniSolar-V-1KW-5KW-manual.pdf· page 30

Warning codes (4)unit keeps running · red LED flashing

W01Warning

Fan locked.

Warning

Warning code 01 flashing on the display: Fan locked.

CauseFan locked.

Recommended fixReplace the fan.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28

W03Warning

Battery over charged.

Warning

Warning code 03 flashing on the display: Battery over charged.

CauseBattery over charged.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28

W04Warning

Low battery.

Warning

Warning code 04 flashing on the display: Low battery.

CauseLow battery.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28

W07Warning

Overload.

Warning

Warning code 07 flashing on the display: Overload.

CauseOverload.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-V-1KW-5KW-manual.pdf· page 28

Still seeing a code on your InfiniSolar V?

Send us the code on your screen and a Voltronic technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about InfiniSolar V error codes

What is the difference between a fault and a warning on the InfiniSolar V?
A fault cuts the unit's output and the red LED stays solid — this page lists 16 of them for the InfiniSolar V. A warning only flashes the red LED and the unit keeps running; there are 4 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Which model numbers does this page cover?
The InfiniSolar V shares its firmware and fault table with 4 other model numbers: InfiniSolar V 1KW, InfiniSolar V 2KW, InfiniSolar V 3KW, InfiniSolar V 4KW, InfiniSolar V 5KW. If your unit is any of these, every code on this page applies to it.
Where do these codes come from?
Every entry was transcribed from InfiniSolar-V-1KW-5KW-manual.pdf — Voltronic's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Voltronic user manuals. Always consult your device manual and a qualified technician before performing repairs.