Also applies to:Axpert MAX II TWIN 8KWAxpert MAX II TWIN 11KWAxpert MAX II TWIN 12KWAxpert MAX II Duplex 8KWAxpert MAX II Duplex 11KWAxpert MAX II 8KWAxpert MAX II 11KWAxpert MAX 8K TWIN PV11K+12
What it means
PV over voltage — Fault code 11 shown on the display with the fault icon on: PV over voltage.
Cause: PV over voltage.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-11K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-8K-Duplex-Off-grid-manual.pdf, p.44 · +12 more official manuals
Also applies to:Axpert KS 1KVAAxpert KS 3KVAAxpert KS 5KVAAxpert 3KP 24VAxpert 5KP 24V
What it means
Main relay failed — Fault code 11 shown on the display with the fault icon on: Main relay failed.
Cause: Main relay failed.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: Axpert-KS-1-5KVA_manual_EN.pdf, p.31 · Axpert-3KP-5KP-24V_manual.pdf, p.26
Also applies to:InfiniSolar V II 2KWInfiniSolar V II 3KWInfiniSolar V II 5KWInfiniSolar V II WP 2KWInfiniSolar V II WP 3KWInfiniSolar V II WP 5KW
What it means
PV voltage over — Fault code 11 shown on the display with the fault icon on: PV voltage over.
Cause: Solar input voltage is more than 450V.
How to fix it
Solar input voltage is more than 450V.
Source: InfiniSolarVII_2KW-3KW-5KW_manual.pdf, p.26 · InfiniSolarVII_2KW-3KW-5KW_manual.pdf, p.28 · InfiniSolar-VII-WP-2KW-3KW-5KW-manual-20201127.pdf, p.29 · +1 more official manuals
What it means
PV voltage over — Fault code 11 shown on the display with the fault icon on: PV voltage over.
Cause: PV voltage is over limitation.
Source: InfiniSolarVII_1.5KW_manual.pdf, p.27 · InfiniSolarVII_1.5KW_manual.pdf, p.29
Also applies to:InfiniSolar V II 2P 6KW
What it means
PV voltage is over — Fault code 11 shown on the display with the fault icon on: PV voltage is over..
Cause: Solar input voltage is more than 450V.
How to fix it
Solar input voltage is more than 450V.
Source: InfiniSolar-VII-2P-6KW-manual-20201207.pdf, p.30 · InfiniSolar-VII-2P-6KW-manual-20201207.pdf, p.32
What it means
Solar over current — Fault code 11 shown on the display with the fault icon on: Solar over current.
Cause: Solar over current.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: InfiniSolar-WP-LV-12KW-Premium-manual.pdf, p.52
Also applies to:InfiniSolar 15KWInfiniSolar Super 4KWInfiniSolar Plus 5KW
What it means
Solar over current — Fault code 11 shown on the display with the fault icon on: Solar over current.
Cause: Surge.
How to fix it
- 1Restart the inverter
- 2If the error message still remains, please contact your installer.
Source: InfiniSolar-10KW-manual-20191126.pdf, p.50 · InfiniSolar-15K-manual-20200313.pdf, p.51 · InfiniSolar-Super-4KW-manual.pdf, p.47 · +1 more official manuals
What it means
Over-current on PV input is detected — Fault code 11 shown on the display with the fault icon on: Over-current on PV input is detected.
Cause: Over-current on PV input is detected.
How to fix it
- 1Disconnect AC circuit breaker first.
- 2Then, disconnect DC circuit breaker.
- 3Until LCD screen completely shuts down, turn on DC breaker first.
- 4It will show "No Utility" in LCD screen.
- 5Then, turn on AC breaker.
- 6After 300 seconds, the system will automatically connect to the grid.
- 7If the error message still remains, please contact your installer.
- 8The internal temperature is higher than specified temperature.
- 9Leave inverter to cool down to room temperature.
- 10If the error message still remains, please contact your installer.
- 11Check if the open circuit voltage of PV modules is higher than 500VDC.
- 12If PV open circuit voltage is less than 500VDC and the error message remains, pelase contact your installer.
- 13Turn off the inverter.
- 14Then, restart the inverter.
- 15If the error message still remains, please contact your installer.
- 16The ground voltage is too high.
- 17Please disconnect AC breaker first and then DC breaker.
- 18Check if grounding is connected properly after LCD screen.
Source: InfiniSolarE-5.5KW-manual.pdf, p.43
Also applies to:InfiniSolar 2KWInfiniSolar 3KW
What it means
Over-current on PV input is detected — Fault code 11 shown on the display with the fault icon on: Over-current on PV input is detected.
Cause: Over-current on PV input is detected.
How to fix it
- 1Disconnect AC circuit breaker first. Then, disconnect DC circuit breaker
- 2Until LCD screen completely shuts down, turn on DC breaker first. It will show "No Utility" in LCD screen. Then, turn on AC breaker. After 300 seconds, the system will automatically connect to the grid
- 3If the error message still remains, please contact your installer.
Source: InfiniSolar-2KW3KW-manual.pdf, p.46
What it means
Solar IP Curr over — Fault code 11 shown on the display with the fault icon on: Solar IP Curr over.
Cause: Surge.
How to fix it
- 1Restart the inverter
- 2If the error message still remains, please contact your installer.
Source: InfiniSolar-TX-PA_manual.pdf, p.50
Energy storage systemFault What it means
Over-current on PV input is detected — Fault code 11 shown on the display with the fault icon on: Over-current on PV input is detected..
Cause: Over-current on PV input is detected.
How to fix it
- 1Disconnect AC circuit breaker first.
- 2Then, disconnect DC circuit breaker.
- 3Until LCD screen completely shuts down, turn on DC breaker first.
- 4It will show "No Utility" in LCD screen.
- 5Then, turn on AC breaker.
- 6After 300 seconds, the system will automatically connect to the grid.
- 7If the error message still remains, please contact your installer.
Source: ESS510-manual.pdf, p.68
Also applies to:Galleon II 6KGalleon II 10KGalleon III 1KGalleon III 2KGalleon III 3KGiant Elite 1P/1P 6K-10KWinner Pro 6KVAWinner Pro 10KVA+3
What it means
Inverter soft start failure — Fault code 11 shown on the display; the UPS has detected a fault condition: Inverter soft start failure.
Cause: Inverter soft start failure.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: GalleonII-6-10K-Tower-RT-manual.pdf, p.29 · Galleon-III-Tower-Rack-1-3K-manual.pdf, p.31 · Giant-Elite-1P-1P_manual.pdf, p.26 · +2 more official manuals
Also applies to:Galleon X9 6K RTGalleon X9 10K RT
What it means
Inv Start Fail — Fault code 11 shown on the display; the UPS has detected a fault condition: Inv Start Fail.
Cause: The internal inverter failed, so the inverter voltage could not start up correctly.
How to fix it
Contact the dealer to repair.
Source: Galleon-X9-6-10K-RT_manual.pdf, p.29
Also applies to:Giant Elite 3P/3P 10K-40KVA
What it means
INV voltage in L2 is too low — Fault code 11 shown on the display; the UPS has detected a fault condition: INV voltage in L2 is too low.
Cause: INV voltage in L2 is too low.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: Giant-Elite-3P3P-manual.pdf, p.41
Also applies to:Winner Pro 1KVA-3KVAOtima II 800VA-3KVAOtima II Tower 1K-5K
What it means
Inverter soft start fail — Fault code 11 shown on the display; the UPS has detected a fault condition: Inverter soft start fail.
Cause: Inverter soft start fail.
How to fix it
- 1Restart the unit.
- 2If the fault happens again, contact your installer or the repair centre.
Source: Winner-Pro_manual.pdf, p.15 · Otima-II-User-Manual.pdf, p.17 · OtimaII-Tower-1K-5K-manual.pdf, p.14