Voltronic Solar Charge Controller Axpert KING II TWIN 6.2KW
- Input Voltage Waveform:Sinusoidal
- Nominal Input Voltage:230Vac

Charge ControllersModel AXPERT-KING-II-TWIN-6KW
The Axpert KING II TWIN 6KW is a solar charge controller.
In stock
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is an Off-Grid Inverter with a maximum PV array power of 6000 W, making it a dependable choice for managing a solar array's charge into a battery bank. It accepts an operating voltage range of 110-280 VAC. It operates at an efficiency of 93% (. Its output waveform is Sinusoidal. It is rated to operate across -10°C to 50°C, with a humidity tolerance of 5% to 95%. The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is certified to CE and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Nominal Input Voltage of 230Vac, Low Loss Voltage of 176Vac±7V and Low Loss Return Voltage of 186Vac+7V.
Specifications last updated 17 August 2026
| Input Voltage Waveform | Sinusoidal |
|---|---|
| Nominal Input Voltage | 230Vac |
| Low Loss Voltage | 176Vac±7V |
| Low Loss Return Voltage | 186Vac+7V |
| High Loss Voltage | 280Vac±7V |
| High Loss Return Voltage | 270Vac±7V |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Low Loss Frequency | 46(56)±1Hz |
| Low Loss Return Frequency | 46.5(57)±1Hz |
| High Loss Frequency | 54(64)±1Hz |
| High Loss Return Frequency | 6KW |
| Power Factor | >0.98 |
| Efficiency (Line Mode) | 93% ( |
| Transfer Time | Inverter-to-bypass 4ms |
| Floating Charging Voltage | 54Vdc |
| Communication | RS232 and Wi-Fi |
|---|---|
| Overcharge Protection | 66Vdc |
| Bypass Mode | 6KW |
| Voltage Range | 110-280 VAC |
| Line Mode | 94% |
| Maximum AC Charge Current | 120A |
| Output Short Circuit Protection | Line mode: Circuit Breaker Battery mode: Electronic Circuits |
| Battery Mode | 92% |
| Surge Capacity | 2* rated power for 5 seconds |
| Nominal DC Input Voltage | 48Vdc |
| No Load Power Consumption | <75W |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Safety Certification | CE |
| Waveform | Pure sine wave |
| Solar Charger type | MPPT |
| Maximum PV Array Power | 6000 W |
| Storage temperature | -15°C~ 60°C |
|---|---|
| Humidity | 5% to 95% |
| Operating Temperature | -10°C to 50°C |
Looking up an error code on this Voltronic Power Axpert KING II TWIN? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW accepts an input voltage range of 110-280 VAC.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW operates across -10°C to 50°C and a humidity range of 5% to 95%.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has an efficiency of 93% (.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW supports a maximum PV array power of 6000 W and a maximum PV array open-circuit voltage of 500 VDC.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a maximum charge current of 120A.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a transfer time of inverter-to-bypass 4ms and an output waveform of Sinusoidal.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW has a power factor of >0.98.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is certified to CE, meeting recognised international standards for safety and performance.
The Voltronic Solar Charge Controller Axpert KING II TWIN 6KW is backed by a 2-year manufacturer warranty from Voltronic Power.