08Fault

Voltronic inverter error 08

Bus voltage is too high

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Axpert MAX II TWIN

InverterFault

Also applies to:Axpert MAX II TWIN 8KWAxpert MAX II TWIN 11KWAxpert MAX II TWIN 12KWAxpert MAX II Duplex 8KWAxpert MAX II Duplex 11KWAxpert MAX II 8KWAxpert MAX II 11KWAxpert MAX 8K TWIN PV11K+46

What it means

Bus voltage is too high

Cause: Internal components failed.

How to fix it

Return to repair center.

Source: Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.55 · Axpert-MAXII-11K-TWIN-Off-grid-manual.pdf, p.47 · +57 more official manuals

What it means

CT sensor faultFault code 08 shown on the display with the fault icon on: CT sensor fault.

Cause: CT sensor fault.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: InfiniSolar-WP-LV-12KW-Premium-manual.pdf, p.52

InfiniSolar 10KW

InverterFault

Also applies to:InfiniSolar 15KWInfiniSolar Super 4KWInfiniSolar Plus 5KW

What it means

CT sensor faultFault code 08 shown on the display with the fault icon on: CT sensor fault.

Cause: Internal components failed.

How to fix it

Please contact your installer.

Source: InfiniSolar-10KW-manual-20191126.pdf, p.50 · InfiniSolar-15K-manual-20200313.pdf, p.51 · InfiniSolar-Super-4KW-manual.pdf, p.47 · +1 more official manuals

InfiniSolar E 5.5KW

InverterFault

What it means

DC component in the output current exceeds the upper thresholdFault code 08 shown on the display with the fault icon on: DC component in the output current exceeds the upper threshold.

Cause: DC component in the output current exceeds the upper threshold.

How to fix it

  1. Disconnect AC circuit breaker first.
  2. Then, disconnect DC circuit breaker.
  3. Until LCD screen completely shuts down, turn on DC breaker first.
  4. It will show "No Utility" in LCD screen.
  5. Then, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If the error message still remains, please contact your installer.
  8. The internal temperature is higher than specified temperature.
  9. Leave inverter to cool down to room temperature.
  10. If the error message still remains, please contact your installer.
  11. Check if the open circuit voltage of PV modules is higher than 500VDC.
  12. If PV open circuit voltage is less than 500VDC and the error message remains, pelase contact your installer.
  13. Turn off the inverter.
  14. Then, restart the inverter.
  15. If the error message still remains, please contact your installer.
  16. The ground voltage is too high.
  17. Please disconnect AC breaker first and then DC breaker.
  18. Check if grounding is connected properly after LCD screen.

Source: InfiniSolarE-5.5KW-manual.pdf, p.43

InfiniSolar 2KW/3KW

InverterFault

Also applies to:InfiniSolar 2KWInfiniSolar 3KW

What it means

DC component in the output current exceeds the upper thresholdFault code 08 shown on the display with the fault icon on: DC component in the output current exceeds the upper threshold.

Cause: DC component in the output current exceeds the upper threshold.

How to fix it

  1. Disconnect AC circuit breaker first. Then, disconnect DC circuit breaker
  2. Until LCD screen completely shuts down, turn on DC breaker first. It will show "No Utility" in LCD screen. Then, turn on AC breaker. After 300 seconds, the system will automatically connect to the grid
  3. If the error message still remains, please contact your installer.

Source: InfiniSolar-2KW3KW-manual.pdf, p.46

What it means

T SCR Close FaultFault code 08 shown on the display with the fault icon on: T SCR Close Fault.

Cause: Internal components failed.

How to fix it

Please contact your installer.

Source: InfiniSolar-TX-PA_manual.pdf, p.50

DC Converter 3KW

InverterFault

What it means

Fan is lockedFault code 08 shown on the display with the fault icon on: Fan is locked..

Cause: Fan is locked.

How to fix it

  1. Check if fan is working
  2. If the problem remains, please contact your installer.

Source: DC-converter-3KW-manual.pdf, p.20 · DC-converter-3KW-manual.pdf, p.21

ESS510

Energy storage systemFault

What it means

DC component in the output current exceeds the upper thresholdFault code 08 shown on the display with the fault icon on: DC component in the output current exceeds the upper threshold..

Cause: DC component in the output current exceeds the upper threshold.

How to fix it

  1. Disconnect AC circuit breaker first.
  2. Then, disconnect DC circuit breaker.
  3. Until LCD screen completely shuts down, turn on DC breaker first.
  4. It will show "No Utility" in LCD screen.
  5. Then, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If the error message still remains, please contact your installer.

Source: ESS510-manual.pdf, p.68

Also applies to:Giant Elite 3P/3P 10K-40KVA

What it means

INV in L2 is short circuitedFault code 08 shown on the display; the UPS has detected a fault condition: INV in L2 is short circuited.

Cause: INV in L2 is short circuited.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: Giant-Elite-3P3P-manual.pdf, p.41

Frequently asked questions

What does error 08 mean on a Voltronic inverter?
It depends on the model — 39 devices use code 08. On the Axpert MAX II TWIN it means: Bus voltage is too high. The card for each model on this page gives its exact meaning and fix.
Is error 08 a fault or a warning?
08 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 08?
Return to repair center. The exact steps for each affected model are listed on this page.