Voltronic ESS-A510 Error Codes: Causes & Fixes (28 codes)

This is the complete fault table for the Voltronic ESS-A510 Energy storage system — all 28 codes from the official manual on one page. On this Voltronic device, a fault code means the unit has entered protection and stopped normal operation; a warning leaves it running. The exact indication (LED pattern or display code) is listed per code below.

Last checked against the official manuals on July 27, 2026.

How to read the severity labels

  • Fault(19)operation stops until cleared
  • Warning(9)unit keeps running · needs attention

Fault codes (19)operation stops until cleared

01Fault

Fan is locked when inverter is off.

Fault

Fault code 01 shown on the display with the fault icon on: Fan is locked when inverter is off..

CauseFan fault.

Recommended fixReplace the fan.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

02Fault

Over temperature.

Fault

Fault code 02 shown on the display with the fault icon on: Over temperature.

CauseInternal temperature of inverter component is over 100°C.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

03Fault

Battery voltage is too high.

Fault

Fault code 03 shown on the display with the fault icon on: Battery voltage is too high.

CauseBattery is over-charged.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

04Fault

Battery voltage is too low.

Fault

Fault code 04 shown on the display with the fault icon on: Battery voltage is too low.

CauseBattery voltage is too low.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 46

05Fault

Output short circuited.

Fault

Fault code 05 shown on the display with the fault icon on: Output short circuited..

CauseOutput short circuited.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

06Fault

Output voltage is too high.

Fault

Fault code 06 shown on the display with the fault icon on: Output voltage is too high..

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

07Fault

Overload time out.

Fault

Fault code 07 shown on the display with the fault icon on: Overload time out.

CauseOverload error. The inverter is overload 110% and time is up.

Recommended fixReduce the connected load by switching off some equipment.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

08Fault

Bus voltage is too high.

Fault

Fault code 08 shown on the display with the fault icon on: Bus voltage is too high.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

09Fault

Bus soft start failed.

Fault

Fault code 09 shown on the display with the fault icon on: Bus soft start failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

10Fault

PV over current.

Fault

Fault code 10 shown on the display with the fault icon on: PV over current.

CausePV over current.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 46

11Fault

PV over voltage.

Fault

Fault code 11 shown on the display with the fault icon on: PV over voltage.

CausePV over voltage.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 46

12Fault

DCDC over current.

Fault

Fault code 12 shown on the display with the fault icon on: DCDC over current.

CauseDCDC over current.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 46

13Fault

Battery discharge over current.

Fault

Fault code 13 shown on the display with the fault icon on: Battery discharge over current.

CauseBattery discharge over current.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 46

51Fault

Over current.

Fault

Fault code 51 shown on the display with the fault icon on: Over current.

CauseOver current or surge.

Recommended fixRestart the unit, if the error happens again, please return to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

52Fault

Bus voltage is too low.

Fault

Fault code 52 shown on the display with the fault icon on: Bus voltage is too low.

CauseBus voltage is too low.

Recommended fixRestart the unit, if the error happens again, please return to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

53Fault

Inverter soft start failed.

Fault

Fault code 53 shown on the display with the fault icon on: Inverter soft start failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

55Fault

Over DC voltage in AC output.

Fault

Fault code 55 shown on the display with the fault icon on: Over DC voltage in AC output.

CauseOutput voltage is unbalanced.

Recommended fixRestart the unit, if the error happens again, please return to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

57Fault

Current sensor failed.

Fault

Fault code 57 shown on the display with the fault icon on: Current sensor failed.

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

58Fault

Output voltage is too low.

Fault

Fault code 58 shown on the display with the fault icon on: Output voltage is too low.

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:ESS-A510-manual.pdf· page 46ESS-A510-manual.pdf· page 53

Warning codes (9)unit keeps running · needs attention

W01Warning

Fan is locked when inverter is on.

Warning

Warning code 01 flashing on the display: Fan is locked when inverter is on.. Audible alarm: second.

CauseFan is locked when inverter is on.

Recommended fixReplace the fan.

Source:ESS-A510-manual.pdf· page 46

W02Warning

Over temperature.

Warning

Warning code 02 flashing on the display: Over temperature.

CauseOver temperature.

Recommended fixCheck whether the air flow of the unit is blocked or whether the ambient temperature is too high.

Source:ESS-A510-manual.pdf· page 46

W03Warning

Battery is over-charged.

Warning

Warning code 03 flashing on the display: Battery is over-charged. Audible alarm: beep once every second.

CauseBattery is over-charged.

Recommended fixReturn to repair center.

Source:ESS-A510-manual.pdf· page 46

W04Warning

Low battery.

Warning

Warning code 04 flashing on the display: Low battery. Audible alarm: beep once every second Beep once every 0.5.

CauseLow battery.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 47

W07Warning

Overload.

Warning

Warning code 07 flashing on the display: Overload. Audible alarm: second.

CauseOverload.

Recommended fixReduce the connected load by switching off some equipment.

Source:ESS-A510-manual.pdf· page 47

W10Warning

Output power derating.

Warning

Warning code 10 flashing on the display: Output power derating. Audible alarm: beep twice every 3 seconds.

CauseOutput power derating.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 47

W15Warning

PV energy is low.

Warning

Warning code 15 flashing on the display: PV energy is low.. Audible alarm: beep twice every 3 seconds.

CausePV energy is low.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 47

W16Warning

High AC input (>280VAC) during BUS soft start.

Warning

Warning code 16 flashing on the display: High AC input (>280VAC) during BUS soft start.

CauseHigh AC input (>280VAC) during BUS soft start.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 47

W32Warning

Communication failure between inverter and display panel.

Warning

Warning code 32 flashing on the display: Communication failure between inverter and display panel.

CauseCommunication failure between inverter and display panel.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:ESS-A510-manual.pdf· page 47

Still seeing a code on your ESS-A510?

Send us the code on your screen and a Voltronic technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about ESS-A510 error codes

What is the difference between a fault and a warning on the ESS-A510?
A fault puts the unit into protection and stops normal operation — this page lists 19 of them for the ESS-A510. A warning leaves the unit running; there are 9 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Does this page apply to other Voltronic models?
No — this table was transcribed specifically from the ESS-A510 manual. Other Voltronic devices have their own pages; start from the error-code hub to find the one matching the model number on your unit's label.
Where do these codes come from?
Every entry was transcribed from ESS-A510-manual.pdf — Voltronic's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Voltronic user manuals. Always consult your device manual and a qualified technician before performing repairs.