24Fault

Voltronic inverter error 24

Fault — the inverter cuts its output and the red LED stays solid until the fault is cleared.

InfiniSolar E 5.5KW

InverterFault

What it means

Battery disconnected — Fault code 24 shown on the display with the fault icon on: Battery disconnected.

Cause: Battery disconnected.

How to fix it

  1. Check if the impedance between positive and negative poles to the ground is greater than 1MΩ.
  2. If the impedance is lower than 1MΩ, please contact your installer.
  3. Please disconnect AC breaker first and then disconnect DC breaker.
  4. After LCD screen is completely off, turn on DC breaker.
  5. Until it shows "No Utility" in LCD display, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If error message remains, please contact your installer.
  8. Check if the connection between battery and inverter is good.
  9. Make sure battery condition is ok.
  10. Then, restart the inverter.
  11. If error message remains, please contact your installer.
  12. Remove exessive loads.
  13. Be sure the total power consumption of the connected loads are less than that of the maximum which this inverter can support.
  14. Then, restart the inverter.
  15. Check if battery cable is connected firmly.
  16. If error message remains, please contact your installer.
  17. Remove exessive loads.
  18. Then, restart the inverter.
  19. Turn off the inverter.
  20. Disconnect AC circuit breaker first.
  21. Then, disconnect DC circuit breaker and then disconnect the loads.
  22. Please check if load circuit is ok.
  23. After removing the error, turn on the PV DC.

Source: Voltronic manual, p.44

Models that show 24

Frequently asked questions

What does error 24 mean on a Voltronic inverter?

It depends on the model — 6 devices use code 24. On the InfiniSolar E 5.5KW it means: Battery disconnected. The card for each model on this page gives its exact meaning and fix.

Is error 24 a fault or a warning?

24 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.

How do I clear or fix error 24?

Check if the impedance between positive and negative poles to the ground is greater than 1MΩ. If the impedance is lower than 1MΩ, please contact your installer. The exact steps for each affected model are listed on this page.

Related error codes

Other codes on the InfiniSolar TX-PA 30KW

24 is in the "Fault" class on the InfiniSolar TX-PA 30KW: 55 of the 76 codes documented for it.

All InfiniSolar TX-PA 30KW codes

Other codes on the Galleon II 6K-10K

24 is in the "Fault" class on the Galleon II 6K-10K: 24 of the 42 codes documented for it.

All Galleon II 6K-10K codes

Other codes on the Galleon X9 6K-10K RT

24 is in the "Fault" class on the Galleon X9 6K-10K RT: 16 of the 28 codes documented for it.

All Galleon X9 6K-10K RT codes

Compiled from official Voltronic user manuals. Always consult your device manual and a qualified technician before performing repairs.