Voltronic InfiniSolar V II 6KW (Split Phase) Error Codes: Causes & Fixes (36)

This is the complete fault table for the Voltronic InfiniSolar V II 6KW (Split Phase) Inverter — all 36 codes from the official manual on one page. On Voltronic units, a fault code means the unit has cut its output and the red LED stays solid; a warning flashes the red LED while the unit keeps running.

Last checked against the official manuals on July 27, 2026.

How to read the severity labels

  • Fault(28)output stops · red LED solid
  • Warning(8)unit keeps running · red LED flashing

Fault codes (28)output stops · red LED solid

01Fault

Fan is locked.

Fault

Fault code 01 shown on the display with the fault icon on: Fan is locked..

CauseFan fault.

Recommended fixReplace the fan.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

02Fault

Over temperature.

Fault

Fault code 02 shown on the display with the fault icon on: Over temperature.

CauseInternal temperature of inverter component is over 100°C.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

03Fault

Battery voltage is too high.

Fault

Fault code 03 shown on the display with the fault icon on: Battery voltage is too high..

CauseBattery is over-charged.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

04Fault

Battery voltage is too low.

Fault

Fault code 04 shown on the display with the fault icon on: Battery voltage is too low..

CauseBattery voltage is too low.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30

05Fault

Output is short circuited.

Fault

Fault code 05 shown on the display with the fault icon on: Output is short circuited..

CauseOutput short circuited.

Recommended fixCheck if wiring is connected well and remove abnormal load.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

06Fault

Output voltage is abnormal.

Fault

Fault code 06 shown on the display with the fault icon on: Output voltage is abnormal..

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

07Fault

Overload time out.

Fault

Fault code 07 shown on the display with the fault icon on: Overload time out..

CauseOverload error. The inverter is overload 110% and time is up.

Recommended fixReduce the connected load by switching off some equipment.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

08Fault

Bus voltage is too high.

Fault

Fault code 08 shown on the display with the fault icon on: Bus voltage is too high..

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

09Fault

Bus soft start failure.

Fault

Fault code 09 shown on the display with the fault icon on: Bus soft start failure..

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

10Fault

PV current is over.

Fault

Fault code 10 shown on the display with the fault icon on: PV current is over..

CauseSurge.

Recommended fixRestart the unit, if the error happens again, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

11Fault

PV voltage is over.

Fault

Fault code 11 shown on the display with the fault icon on: PV voltage is over..

CauseSolar input voltage is more than 450V.

Recommended fixSolar input voltage is more than 450V.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

12Fault

Charge current is over.

Fault

Fault code 12 shown on the display with the fault icon on: Charge current is over..

CauseDC/DC over current or surge.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

51Fault

Over current or surge.

Fault

Fault code 51 shown on the display with the fault icon on: Over current or surge.

CauseOver current or surge.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

52Fault

Bus voltage is too low.

Fault

Fault code 52 shown on the display with the fault icon on: Bus voltage is too low..

CauseBus voltage is too low.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

53Fault

Inverter soft start failure.

Fault

Fault code 53 shown on the display with the fault icon on: Inverter soft start failure..

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

55Fault

Over DC offset in AC output.

Fault

Fault code 55 shown on the display with the fault icon on: Over DC offset in AC output.

CauseOutput voltage is unbalanced.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

56Fault

Battery is not connected.

Fault

Fault code 56 shown on the display with the fault icon on: Battery is not connected..

CauseBattery is not connected well or fuse is burnt.

Recommended fixIf the battery is connected well, please return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

57Fault

Current sensor failure.

Fault

Fault code 57 shown on the display with the fault icon on: Current sensor failure..

CauseInternal components failed.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

58Fault

Output voltage is too low.

Fault

Fault code 58 shown on the display with the fault icon on: Output voltage is too low..

CauseOutput abnormal (Inverter voltage below than 190Vac or is higher than 260Vac).

Recommended fix1. Reduce the connected load. 2. Return to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 30InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 32

60Fault

Power feedback protection.

Fault

Fault code 60 shown on the display with the fault icon on: Power feedback protection.

CausePower feedback protection.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

71Fault

Firmware version inconsistent.

Fault

Fault code 71 shown on the display with the fault icon on: Firmware version inconsistent.

CauseFirmware version inconsistent.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

72Fault

Current sharing fault.

Fault

Fault code 72 shown on the display with the fault icon on: Current sharing fault.

CauseCurrent sharing fault.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

80Fault

CAN fault.

Fault

Fault code 80 shown on the display with the fault icon on: CAN fault.

CauseCAN fault.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

81Fault

Host loss.

Fault

Fault code 81 shown on the display with the fault icon on: Host loss.

CauseHost loss.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

82Fault

Synchronization loss.

Fault

Fault code 82 shown on the display with the fault icon on: Synchronization loss.

CauseSynchronization loss.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

83Fault

Battery voltage detected different.

Fault

Fault code 83 shown on the display with the fault icon on: Battery voltage detected different.

CauseBattery voltage detected different.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

84Fault

AC input voltage and frequency detected different.

Fault

Fault code 84 shown on the display with the fault icon on: AC input voltage and frequency detected different.

CauseAC input voltage and frequency detected different.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

85Fault

AC output current unbalance.

Fault

Fault code 85 shown on the display with the fault icon on: AC output current unbalance.

CauseAC output current unbalance.

Recommended fixRestart the unit. If the fault happens again, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 41

Warning codes (8)unit keeps running · red LED flashing

W01Warning

Fan locked.

Warning

Warning code 01 flashing on the display: Fan locked.

CauseFan locked.

Recommended fixReplace the fan.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W02Warning

Over temperature.

Warning

Warning code 02 flashing on the display: Over temperature.

CauseOver temperature.

Recommended fixReturn to repair center.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W03Warning

Battery over charged.

Warning

Warning code 03 flashing on the display: Battery over charged.

CauseBattery over charged.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W04Warning

Low battery.

Warning

Warning code 04 flashing on the display: Low battery.

CauseLow battery.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W07Warning

Overload.

Warning

Warning code 07 flashing on the display: Overload.

CauseOverload.

Recommended fixReduce the connected load by switching off some equipment.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W10Warning

Inverter power derating.

Warning

Warning code 10 flashing on the display: Inverter power derating.

CauseInverter power derating.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W15Warning

PV is weak.

Warning

Warning code 15 flashing on the display: PV is weak.

CausePV is weak.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

W19Warning

Battery is not connected.

Warning

Warning code 19 flashing on the display: Battery is not connected.

CauseBattery is not connected.

Recommended fixThe unit keeps operating. Clear the condition shown and the warning resets automatically; if it persists, contact your installer or the repair centre.

Source:InfiniSolar-VII-2P-6KW-manual-20201207.pdf· page 29

Still seeing a code on your InfiniSolar V II 6KW (Split Phase)?

Send us the code on your screen and a Voltronic technician will reply with the exact steps for your unit. Support is free for life — a first diagnosis never needs a callout.

Keep troubleshooting

Related devices

Common questions about InfiniSolar V II 6KW (Split Phase) error codes

What is the difference between a fault and a warning on the InfiniSolar V II 6KW (Split Phase)?
A fault cuts the unit's output and the red LED stays solid — this page lists 28 of them for the InfiniSolar V II 6KW (Split Phase). A warning only flashes the red LED and the unit keeps running; there are 8 warning codes here. Resolve the cause of a fault before restarting; warnings can usually be cleared while the unit runs.
Does this page apply to other Voltronic models?
No — this table was transcribed specifically from the InfiniSolar V II 6KW (Split Phase) manual. Other Voltronic devices have their own pages; start from the error-code hub to find the one matching the model number on your unit's label.
Where do these codes come from?
Every entry was transcribed from InfiniSolar-VII-2P-6KW-manual-20201207.pdf — Voltronic's official documentation. Each row cites its source manual (and page where printed), so you can verify the wording before acting on it.

Compiled from official Voltronic user manuals. Always consult your device manual and a qualified technician before performing repairs.