13Fault

Voltronic inverter error 13

Battery discharge over current

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

Axpert MAX II TWIN

InverterFault

Also applies to:Axpert MAX II TWIN 8KWAxpert MAX II TWIN 11KWAxpert MAX II TWIN 12KWAxpert MAX II Duplex 8KWAxpert MAX II Duplex 11KWAxpert MAX II 8KWAxpert MAX II 11KWAxpert MAX 8K TWIN PV11K+7

What it means

Battery discharge over currentFault code 13 shown on the display with the fault icon on: Battery discharge over current.

Cause: Battery discharge over current.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: Axpert-MAXII-8K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-11K-TWIN-Off-grid-manual.pdf, p.47 · Axpert-MAXII-8K-Duplex-Off-grid-manual.pdf, p.44 · +8 more official manuals

What it means

PV ISO faultFault code 13 shown on the display with the fault icon on: PV ISO fault.

Cause: PV ISO fault.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: InfiniSolar-WP-LV-12KW-Premium-manual.pdf, p.52

InfiniSolar 10KW

InverterFault

Also applies to:InfiniSolar 15KWInfiniSolar Plus 5KW

What it means

PV ISO faultFault code 13 shown on the display with the fault icon on: PV ISO fault.

Cause: The resistance between PV and ground is too low.

How to fix it

  1. Check the wire and panels which may cause the leakage
  2. If the error message still remains, please contact your installer.

Source: InfiniSolar-10KW-manual-20191126.pdf, p.51 · InfiniSolar-15K-manual-20200313.pdf, p.51 · InfiniSolar-Plus-5KW-manual.pdf, p.52

InfiniSolar E 5.5KW

InverterFault

What it means

PV insulation resistance is too lowFault code 13 shown on the display with the fault icon on: PV insulation resistance is too low.

Cause: PV insulation resistance is too low.

How to fix it

  1. Check if the impedance between positive and negative poles to the ground is greater than 1MΩ.
  2. If the impedance is lower than 1MΩ, please contact your installer.
  3. Please disconnect AC breaker first and then disconnect DC breaker.
  4. After LCD screen is completely off, turn on DC breaker.
  5. Until it shows "No Utility" in LCD display, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If error message remains, please contact your installer.
  8. Check if the connection between battery and inverter is good.
  9. Make sure battery condition is ok.
  10. Then, restart the inverter.
  11. If error message remains, please contact your installer.
  12. Remove exessive loads.
  13. Be sure the total power consumption of the connected loads are less than that of the maximum which this inverter can support.
  14. Then, restart the inverter.
  15. Check if battery cable is connected firmly.
  16. If error message remains, please contact your installer.
  17. Remove exessive loads.
  18. Then, restart the inverter.
  19. Turn off the inverter.
  20. Disconnect AC circuit breaker first.
  21. Then, disconnect DC circuit breaker and then disconnect the loads.
  22. Please check if load circuit is ok.
  23. After removing the error, turn on the PV DC.

Source: InfiniSolarE-5.5KW-manual.pdf, p.44

What it means

PV ISO faultFault code 13 shown on the display with the fault icon on: PV ISO fault.

Cause: The resistance.

How to fix it

  1. Check the wire and panels which may cause the leakage
  2. If the error message still.

Source: InfiniSolar-Super-4KW-manual.pdf, p.47

InfiniSolar 2KW/3KW

InverterFault

Also applies to:InfiniSolar 2KWInfiniSolar 3KW

What it means

PV insulation resistance is too lowFault code 13 shown on the display with the fault icon on: PV insulation resistance is too low.

Cause: PV insulation resistance is too low.

How to fix it

  1. Check if the impedance between positive and negative poles to the ground is greater than 1MΩ
  2. If the impedance is lower than 1MΩ, please contact your installer.

Source: InfiniSolar-2KW3KW-manual.pdf, p.47

ESS510

Energy storage systemFault

What it means

PV insulation resistance is too lowFault code 13 shown on the display with the fault icon on: PV insulation resistance is too low..

Cause: PV insulation resistance is too low.

How to fix it

  1. Check if the impedance between positive and negative poles to the ground is greater than 1MΩ.
  2. If the impedance is lower than 1MΩ, please contact your installer.

Source: ESS510-manual.pdf, p.69

Also applies to:Galleon II 6KGalleon II 10KGiant Elite 1P/1P 6K-10KWinner Pro 6KVAWinner Pro 10KVA

What it means

Low Inverter voltageFault code 13 shown on the display; the UPS has detected a fault condition: Low Inverter voltage.

Cause: Low Inverter voltage.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: GalleonII-6-10K-Tower-RT-manual.pdf, p.29 · Giant-Elite-1P-1P_manual.pdf, p.26 · WinnerPro-6-10KVA_manual.pdf, p.23

Also applies to:Galleon III 1KGalleon III 2KGalleon III 3KWinner Pro 1KVA-3KVAWinner Pro+ 1KWinner Pro+ 2KWinner Pro+ 3KOtima II 800VA-3KVA+1

What it means

Inverter voltage LowFault code 13 shown on the display; the UPS has detected a fault condition: Inverter voltage Low.

Cause: Inverter voltage Low.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: Galleon-III-Tower-Rack-1-3K-manual.pdf, p.31 · Winner-Pro_manual.pdf, p.15 · WinnerProPlus-1-3K-Tower-Rack_manual.pdf, p.24 · +2 more official manuals

Also applies to:Galleon X9 6K RTGalleon X9 10K RT

What it means

Inv Volt LowFault code 13 shown on the display; the UPS has detected a fault condition: Inv Volt Low.

Cause: The internal inverter failed, so the inverter voltage is too low.

How to fix it

Contact the dealer to repair.

Source: Galleon-X9-6-10K-RT_manual.pdf, p.29

Also applies to:Giant Elite 3P/3P 10K-40KVA

What it means

INV voltage in L1 is too highFault code 13 shown on the display; the UPS has detected a fault condition: INV voltage in L1 is too high.

Cause: INV voltage in L1 is too high.

How to fix it

  1. Restart the unit.
  2. If the fault happens again, contact your installer or the repair centre.

Source: Giant-Elite-3P3P-manual.pdf, p.41

Frequently asked questions

What does error 13 mean on a Voltronic inverter?
It depends on the model — 27 devices use code 13. On the Axpert MAX II TWIN it means: Battery discharge over current. The card for each model on this page gives its exact meaning and fix.
Is error 13 a fault or a warning?
13 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 13?
Restart the unit. If the fault happens again, contact your installer or the repair centre. The exact steps for each affected model are listed on this page.