22Fault

Voltronic inverter error 22

Battery high voltage fault

Faultthe inverter cuts its output and the red LED stays solid until the fault is cleared.

The exact meaning depends on your model:

InfiniSolar 10KW

InverterFault

Also applies to:InfiniSolar 15KWInfiniSolar Super 4KWInfiniSolar Plus 5KW

What it means

Battery high voltage faultFault code 22 shown on the display with the fault icon on: Battery high voltage fault.

Cause: Battery voltage exceeds the limit.

How to fix it

  1. Check the battery voltage
  2. If the error message still remains, please contact your installer.

Source: InfiniSolar-10KW-manual-20191126.pdf, p.51 · InfiniSolar-15K-manual-20200313.pdf, p.52 · InfiniSolar-Super-4KW-manual.pdf, p.48 · +1 more official manuals

InfiniSolar E 5.5KW

InverterFault

What it means

Charging voltage is too highFault code 22 shown on the display with the fault icon on: Charging voltage is too high.

Cause: Charging voltage is too high.

How to fix it

  1. Check if the impedance between positive and negative poles to the ground is greater than 1MΩ.
  2. If the impedance is lower than 1MΩ, please contact your installer.
  3. Please disconnect AC breaker first and then disconnect DC breaker.
  4. After LCD screen is completely off, turn on DC breaker.
  5. Until it shows "No Utility" in LCD display, turn on AC breaker.
  6. After 300 seconds, the system will automatically connect to the grid.
  7. If error message remains, please contact your installer.
  8. Check if the connection between battery and inverter is good.
  9. Make sure battery condition is ok.
  10. Then, restart the inverter.
  11. If error message remains, please contact your installer.
  12. Remove exessive loads.
  13. Be sure the total power consumption of the connected loads are less than that of the maximum which this inverter can support.
  14. Then, restart the inverter.
  15. Check if battery cable is connected firmly.
  16. If error message remains, please contact your installer.
  17. Remove exessive loads.
  18. Then, restart the inverter.
  19. Turn off the inverter.
  20. Disconnect AC circuit breaker first.
  21. Then, disconnect DC circuit breaker and then disconnect the loads.
  22. Please check if load circuit is ok.
  23. After removing the error, turn on the PV DC.

Source: InfiniSolarE-5.5KW-manual.pdf, p.44

InfiniSolar 2KW/3KW

InverterFault

Also applies to:InfiniSolar 2KWInfiniSolar 3KW

What it means

Charging voltage is too highFault code 22 shown on the display with the fault icon on: Charging voltage is too high.

Cause: Charging voltage is too high.

How to fix it

  1. Check if the connection between battery and inverter is well
  2. Make sure battery condition is ok
  3. Then, restart the inverter
  4. If error message remains, please contact your installer.

Source: InfiniSolar-2KW3KW-manual.pdf, p.48

What it means

Bat volt overFault code 22 shown on the display with the fault icon on: Bat volt over.

Cause: Battery voltage exceeds the limit.

How to fix it

  1. Check the battery voltage
  2. If the error message still remains, please contact your installer.

Source: InfiniSolar-TX-PA_manual.pdf, p.50

ESS510

Energy storage systemFault

What it means

Charging voltage is too highFault code 22 shown on the display with the fault icon on: Charging voltage is too high..

Cause: Charging voltage is too high.

How to fix it

  1. Check if the connection between battery and inverter is good.
  2. Make sure battery condition is ok.
  3. Then, restart the inverter.
  4. If error message remains, please contact your installer.

Source: ESS510-manual.pdf, p.69

Frequently asked questions

What does error 22 mean on a Voltronic inverter?
It depends on the model — 8 devices use code 22. On the InfiniSolar 10KW it means: Battery high voltage fault. The card for each model on this page gives its exact meaning and fix.
Is error 22 a fault or a warning?
22 is a fault code: the inverter cuts its output and the red LED stays solid until it is cleared.
How do I clear or fix error 22?
1. Check the battery voltage. The exact steps for each affected model are listed on this page.

Related error codes

Compiled from official Voltronic user manuals. Always consult your device manual and a qualified technician before performing repairs.