Voltronic Galleon III 3P/3P 60KL
Discover the Voltronic Power Galleon III 3P/3P 60KL Online UPS with 3 x 380/400/415 VAC output and ±1% voltage regulation.
- Rated Output Power (VA): 60kVA
- Rated Output Power (W): 60kW
- Voltage: 3x 380-415 VAC (3P)
- Voltage Range: 190-520 VAC (3P)
- Power Factor: >= 0.99
In stock
Voltronic Galleon III 3P/3P 60KL features
About the Voltronic Galleon III 3P/3P 60KL
The Voltronic Power Galleon III 3P/3P 60KL is a robust online UPS designed to deliver reliable power protection. With a nominal voltage of 3 x 380/400/415 VAC and precise AC voltage regulation of ±1%, it ensures optimal performance for critical applications. Ideal for data centers, industrial facilities, and telecommunications, the Galleon III provides seamless power continuity and protection against voltage fluctuations.
Specifications last updated 23 July 2026
Voltronic Galleon III 3P/3P 60KL full specifications
Electrical
| Rated Output Power (VA) | 60kVA |
|---|---|
| Rated Output Power (W) | 60kW |
| Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46-54 Hz or 56-64 Hz |
| Power Factor | ≥ 0.99 @ 100% Load |
| Output Voltage | 3 x 380/400/415 VAC (3Ph+N) |
| AC Voltage Regulation | ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≤ 2% THD (Linear Load) ; ≤ 5% THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sine wave |
| AC Mode | 95.5% |
| ECO Mode | 98.5% |
| Battery Type | 12V/9Ah |
| Numbers | (16+16)pcs x 2 strings |
| Charging Current (max.) | 1A-18A(Adjustable) |
| Charging Voltage | 213-650V(N=16-20) |
| Smart RS-232 / USB | Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Battery Mode | 94.5% |
Mechanical
| Dimension, DxWxH (mm) | 815 x 300 x 1000 |
|---|---|
| Weight (kg) | N/A |
| Long-run Model Dimension, DxWxH (mm) | 815 x 300 x 1000 |
| Long-run Model Net Weight (kgs) | 74 |
| Weight | 74 kg |
Environmental
| Operation Temperature | 0-40°C |
|---|---|
| Humidity | < 95% and non-condensing |
| Noise Level | Less than 70 dB @ 1 Meter |
Related Products

Galleon III 3P/3P 40K
- Rated Output Power (VA):40kVA
- Rated Output Power (W):40kW

Galleon III 3P/3P 30K
- Rated Output Power (VA):30kVA
- Rated Output Power (W):30kW

Galleon III 33/31/11 10KL-20KL RT
- Voltage:220-415 VAC
- Voltage Range:190-520 VAC (3P)

Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
- Nominal Voltage:3x 360-415 VAC (3Ph+N)
- Voltage Range:110-457 VAC

Galleon III 3P/3P 30K~60K Rack
- Voltage:3x 380-415 VAC (3P)
- Voltage Range:190-520 VAC (3P)

Galleon III 33/31/11 10K-20K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:190-520 VAC


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →