Voltronic Galleon III 3P/3P 30K~60K Rack
Discover the Voltronic Power Galleon III 3P/3P 30K~60K Rack with 3x 380/400/415 VAC nominal voltage and precise AC voltage regulation.
- Voltage: 3x 380-415 VAC (3P)
- Voltage Range: 190-520 VAC (3P)
- Power Factor: >= 0.99
In stock
Voltronic Galleon III 3P/3P 30K~60K Rack features
About the Voltronic Galleon III 3P/3P 30K~60K Rack
The Voltronic Power Galleon III 3P/3P 30K~60K Rack is a robust online UPS solution designed for critical applications. With a nominal voltage of 3x 380/400/415 VAC and precise AC voltage regulation, it ensures reliable power delivery even under demanding conditions. Ideal for data centers, industrial facilities, and telecommunications, the Galleon III provides seamless power protection and stability.
Specifications last updated 27 March 2026
Voltronic Galleon III 3P/3P 30K~60K Rack full specifications
Electrical
| Nominal Voltage | 3x 380/400/415 VAC (3Ph+N) |
|---|---|
| Voltage Range | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load |
| Frequency | 46-54 Hz or 56-64 Hz |
| Power Factor | ≥ 0.99 @ 100% load |
| Output Voltage | 3x 380/400/415 VAC (3Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized Range) | 46-54 Hz or 56-64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time AC mode to Battery mode | 0 ms |
| Transfer Time Inverter to Bypass | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| Overload | 100-110% for 60 min, 110-125% for 10 min, 125%-150% for 1 min; >150% immediately |
| AC Mode | 95.5% |
| ECO Mode | 98.5% |
| Battery Type | Depending on the applications |
| Battery Numbers | ±16 ~20 (Adjustable) |
| Charging Current (max.) | 1A~12A (Adjustable) / 1A~12A (Adjustable) / 1A~18A (Adjustable) |
| Charging Voltage | +/-(13.65V x N (N=16~20)) |
| Smart RS-232/USB | Supports Windows® family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Battery Mode | 94.5% |
Mechanical
| Dimension, D x W x H (mm) | 680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] |
|---|---|
| Net Weight (Kgs) | 32 / 34 / 45 |
| Weight | 32 / 34 / 45 |
Environmental
| Operating Temperature | 0-40°C |
|---|---|
| Operating Humidity | < 95 % and non-condensing |
| Noise Level | Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 70dB @ 1 Meter |
Related Products

Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
- Nominal Voltage:3x 360-415 VAC (3Ph+N)
- Voltage Range:110-457 VAC

Galleon III 33/31/11 10K-20K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:190-520 VAC

Galleon III 3P/3P 30K
- Rated Output Power (VA):30kVA
- Rated Output Power (W):30kW

Galleon III 3P/3P 40K
- Rated Output Power (VA):40kVA
- Rated Output Power (W):40kW

Galleon III 3P/3P 60KL
- Rated Output Power (VA):60kVA
- Rated Output Power (W):60kW

Galleon III 33/31/11 10KL-20KL RT
- Voltage:220-415 VAC
- Voltage Range:190-520 VAC (3P)


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →