Voltronic Galleon III 33/31/11 10K-20K
Discover the Voltronic Power Galleon III 33/31/11 10K-20K Online UPS with 3 x 380/400/415VAC voltage, ensuring reliable power protection.
- Nominal Voltage: 3x 380/400/415 VAC
- Voltage Range: 190-520 VAC
- Power Factor: >= 0.99
In stock
Voltronic Galleon III 33/31/11 10K-20K features
About the Voltronic Galleon III 33/31/11 10K-20K
The Voltronic Power Galleon III 33/31/11 Online UPS is engineered to deliver superior power protection with its robust voltage capabilities. Designed for both three-phase and single-phase systems, it ensures consistent performance across a wide voltage and frequency range. Ideal for data centers, telecommunications, and industrial applications, the Galleon III 33/31/11 provides reliable power backup and voltage regulation.
Specifications last updated 23 July 2026
Voltronic Galleon III 33/31/11 10K-20K full specifications
Electrical
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
|---|---|
| Voltage Range | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load / 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
| Frequency Range | 46-54Hz or 56-64Hz / 46-54Hz or 56-64Hz |
| Power Factor | >= 0.99 @ 100% load / >= 0.99 @ 100% load |
| Harmonic Distortion (THDi) | < 4% @ full linear load / < 4% @ full linear load |
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) / 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 0 / 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave / Pure Sinewave |
| Overload Capacity | > 130% : 1 minute (default), continuously working until breaker protection (optional) / > 130% : 1 minute (default), continuously working until breaker protection (optional) |
| AC Mode | 95.5% / 96% |
| ECO Mode | 98.5% |
| Battery Mode | 94.5% / 95.5% |
| Battery Type | 12V / 9Ah / 12V / 9Ah |
| Numbers (default) | (10+10) pcs / (16+16) pcs |
| Typical Recharge Time | 9 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Charging Current (max.) | 1A (default) / 1A (default) |
| Charging Voltage | +/-136.5 VDC / +/-218VDC |
| Long-run Model | ±8-10 / ±16-20 |
| Safety | EN 62040-1:2008/A1:2013;IEC 62040-1:2008/A1:2013;CE low voltage directive |
| EMC | EN 62040-2: 2006(C3) CE EMC directive |
| Smart RS-232/USB | Supports Windows® family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
Mechanical
| Standard Dimension, D x W x H (mm) | 630 x 250 x 826 |
|---|---|
| Model Net Weight (kgs) | 80 / 133 |
| Long-run Dimension, D x W x H (mm) | 630 x 250 x 826 |
| Long-run Model Net Weight (kgs) | 25 / 37 |
| Weight | 80 / 133 kg |
Environmental
| Operation Temperature | 0-40°C |
|---|---|
| Operation Humidity | <95% and non-condensing |
| Altitude | 0 ~ 1500m at full load |
| Noise Level | Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter |
Certifications
- CE
- EN 62040-1
- IEC 62040-1
- EN 62040-2
Related Products

Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
- Nominal Voltage:3x 360-415 VAC (3Ph+N)
- Voltage Range:110-457 VAC

Galleon III 3P/3P 30K~60K Rack
- Voltage:3x 380-415 VAC (3P)
- Voltage Range:190-520 VAC (3P)

Galleon III 3P/3P 30K
- Rated Output Power (VA):30kVA
- Rated Output Power (W):30kW

Galleon III 3P/3P 40K
- Rated Output Power (VA):40kVA
- Rated Output Power (W):40kW

Galleon III 3P/3P 60KL
- Rated Output Power (VA):60kVA
- Rated Output Power (W):60kW

Galleon III 33/31/11 10KL-20KL RT
- Voltage:220-415 VAC
- Voltage Range:190-520 VAC (3P)


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →