Voltronic Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
Discover Voltronic Power's Galleon II & III UPS systems with 3P/3P 10-40KVA, offering precise voltage regulation and wide frequency range.
- Nominal Voltage: 3x 360-415 VAC (3Ph+N)
- Voltage Range: 110-457 VAC
- Power Factor: > 0.99
In stock
Voltronic Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA features
About the Voltronic Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
Voltronic Power's Galleon II and III UPS systems are engineered for superior performance with 3P/3P configurations ranging from 10KVA to 40KVA. These systems ensure reliable power with precise voltage regulation and adaptable frequency ranges, making them ideal for critical applications. The Galleon series is perfect for data centers, industrial operations, and sensitive electronic environments where consistent power supply is crucial.
Specifications last updated 27 March 2026
Voltronic Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA full specifications
Electrical
| Nominal Voltage | 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) |
|---|---|
| Voltage Range | 110-300 VAC ± 3 % @ 50% load; 176-276 VAC ± 3 % @ 100% load / 305VAC~457VAC / 305VAC~457VAC / 305VAC~457VAC |
| Frequency Range | 46-54 Hz or 56-64Hz / 40-70 Hz / 40-70 Hz / 40-70 Hz |
| Power Factor | > 0.99 @ 100% Load / N/A / N/A / N/A |
| Harmonic Distortion (THDi) | < 4% at full linear load / N/A / N/A / N/A |
| AC Voltage Regulation (Batt. Mode) | ± 1% / N/A / N/A / N/A |
| Frequency Range (Synchronized Range) | 46~54Hz or 56~64Hz / N/A / N/A / N/A |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50/60 Hz ± 1% / 50/60 Hz ± 1% / 50/60 Hz ± 1% |
| Current Crest Ratio | 3:1 (max.) / N/A / N/A / N/A |
| Harmonic Distortion | ≤ 2% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) / N/A / N/A / N/A |
| Transfer Time | Zero / N/A / N/A / N/A |
| Waveform (Batt. Mode) | Pure Sine wave / N/A / N/A / N/A |
| Overload AC Mode | 100-110% for 60 min, 111-125% for 10 min, 126%-150% for 1 min; >150% immediately shutdown / N/A / N/A / N/A |
| AC Mode | 95.5% / N/A / N/A / N/A |
| ECO Mode | 98.5% / N/A / N/A / N/A |
| Battery Mode | 94.5% / N/A / N/A / N/A |
| Battery Type | 12V/9Ah / N/A / N/A / N/A |
| Numbers | (10+10) pcs / (16+16) pcs x 2 / (16+16) pcs x 2 / (16+16) pcs x 2 |
| Standard Model Recharge Time | 9 hours recover to 90% capacity / N/A / N/A / N/A |
| Charging Current (max.) | 1A (Default) / 2A (Default) / 2A (Default) / 2A (Default) |
| Charging Voltage | +/-136.5 VDC / +/-218 VDC / +/-218 VDC / +/-218 VDC |
| Smart RS-232 / USB | Supports Windows® Family, Linux and MAC / N/A / N/A / N/A |
| Optional SNMP | Power management from SNMP manager and web browser / N/A / N/A / N/A |
| Battery Mode | 94.5% |
Mechanical
| Standard Model Dimension, DxWxH (mm) | 630 x 250 x 826 / 815 x 300 x 1000 / 815 x 300 x 1000 / 815 x 300 x 1000 |
|---|---|
| Net Weight (kgs) | 139 / 207 / 207 / 207 |
| Weight | 139 / 207 / 207 / 207 |
Environmental
| Operation Temperature | 0-40°C / N/A / N/A / N/A |
|---|---|
| Operation Humidity | < 95% and non-condensing / N/A / N/A / N/A |
| Altitude | 0 – 1500m at full load / N/A / N/A / N/A |
Related Products

Galleon III 3P/3P 30K~60K Rack
- Voltage:3x 380-415 VAC (3P)
- Voltage Range:190-520 VAC (3P)

Galleon III 33/31/11 10K-20K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:190-520 VAC

Galleon III 3P/3P 30K
- Rated Output Power (VA):30kVA
- Rated Output Power (W):30kW

Galleon III 3P/3P 40K
- Rated Output Power (VA):40kVA
- Rated Output Power (W):40kW

Galleon III 3P/3P 60KL
- Rated Output Power (VA):60kVA
- Rated Output Power (W):60kW

Galleon III 33/31/11 10KL-20KL RT
- Voltage:220-415 VAC
- Voltage Range:190-520 VAC (3P)


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →