Voltronic Power Three-Phase Online UPS GALLEON-III-33-31-11-10K-20K
Discover the Voltronic Power Galleon III 33/31/11 10K-20K Online UPS with 3 x 380/400/415VAC voltage, ensuring reliable power protection.
Models and prices
- VOLTRONIC-GALLEON-III-33-31-11-10K-20KAED 28,000incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-GALLEON-III-33-31-11-10K-20K |
|---|---|
| Bypass | |
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| Overload Capacity | > 130% : 1 minute (default), continuously working until breaker protection (optional) / > 130% : 1 minute (default), continuously working until breaker protection (optional) |
| Input | |
| Voltage Range | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load / 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
| Frequency Range | 46-54Hz or 56-64Hz / 46-54Hz or 56-64Hz |
| Power Factor | >= 0.99 @ 100% load / >= 0.99 @ 100% load |
| Harmonic Distortion (THDi) | < 4% @ full linear load / < 4% @ full linear load |
| Output | |
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) / 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 0 / 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave / Pure Sinewave |
| Electrical Data | |
| AC Mode | 95.5% / 96% |
| Battery Mode | 94.5% / 95.5% |
| Numbers (default) | (10+10) pcs / (16+16) pcs |
| Long-run Model | ±8-10 / ±16-20 |
| Efficiency | |
| ECO Mode | 98.5% |
| Battery | |
| Battery Type | 12V / 9Ah / 12V / 9Ah |
| Typical Recharge Time | 9 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Battery Data | |
| Charging Current (max.) | 1A (default) / 1A (default) |
| Charging Voltage | +/-136.5 VDC / +/-218VDC |
| Standards | |
| Safety | EN 62040-1:2008/A1:2013;IEC 62040-1:2008/A1:2013;CE low voltage directive |
| EMC | EN 62040-2: 2006(C3) CE EMC directive |
| Communication | |
| Smart RS-232/USB | Supports Windows® family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Physical | |
| Standard Dimension, D x W x H (mm) | 630 x 250 x 826 |
| Long-run Dimension, D x W x H (mm) | 630 x 250 x 826 |
| Mechanical Data | |
| Model Net Weight (kgs) | 80 / 133 |
| Long-run Model Net Weight (kgs) | 25 / 37 |
| Additional Specifications | |
| Weight | 80 / 133 kg |
| Operating Conditions | |
| Operation Temperature | 0-40°C |
| Operation Humidity | <95% and non-condensing |
| Altitude | 0 ~ 1500m at full load |
| Noise Level | Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True double-conversion
- Flexible system configuration as 3-in/3-out,: Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
- DSP technology guarantees high performance
- Output power factor 1.0
- Active power factor correction in: Active power factor correction in all phases
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy: ECO mode operation for energy saving (ECO)
- Dual AC inputs
- Emergency power off function (EPO)
- Generator compatible
- Adjustable battery numbers for long-run: Adjustable battery numbers for long-run model
- Parallel operation up to 4: Parallel operation up to 4 units with common battery
Frequently Asked Questions
What voltage does the Voltronic UPS Galleon III 33/31/11 10K-20K operate on?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) / 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) and an operating voltage range of 190-520 VAC @ 50% load.
What are the physical dimensions and weight of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K measures 630 x 250 x 826 and weighs 80 / 133.
What is the operating temperature range of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K operates across 0-40°C and a humidity range of <95% and non-condensing.
What is the maximum charge current of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a maximum charge current of 1A (default) / 1A (default).
What output waveform does the Voltronic UPS Galleon III 33/31/11 10K-20K produce?
The Voltronic UPS Galleon III 33/31/11 10K-20K produces a Pure Sinewave / Pure Sinewave output waveform.
How does the Voltronic UPS Galleon III 33/31/11 10K-20K regulate voltage?
The Voltronic UPS Galleon III 33/31/11 10K-20K provides a voltage regulation of ± 1% / ± 1%.
How loud is the Voltronic UPS Galleon III 33/31/11 10K-20K during operation?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a noise level of Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter during operation.
What is the power quality of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a power factor of >= 0.99 @ 100% load / >= 0.99 @ 100% load and a harmonic distortion of < 4% @ full linear load / < 4% @ full linear load.
What certifications does the Voltronic UPS Galleon III 33/31/11 10K-20K have?
The Voltronic UPS Galleon III 33/31/11 10K-20K is certified to CE, EN 62040-1, IEC 62040-1 and EN 62040-2, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K is backed by a 2-year manufacturer warranty from Voltronic Power.