Voltronic Power Three-Phase Online UPS GALLEON-III-33-31-11-10K-20K

Discover the Voltronic Power Galleon III 33/31/11 10K-20K Online UPS with 3 x 380/400/415VAC voltage, ensuring reliable power protection.

Models Covered: VOLTRONIC-GALLEON-III-33-31-11-10K-20K

Manufacturer: Voltronic Power Technology Corp.

Application: The Voltronic UPS Galleon III 33/31/11 10K-20K is a Three Phase Online UPS with a voltage regulation of ± 1% / ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 190-520 VAC @ 50% load. Its output waveform is Pure Sinewave / Pure Sinewave. The unit measures 630 x 250 x 826 and weighs 80 / 133. It is rated to operate across 0-40°C, with a humidity tolerance of <95% and non-condensing. The Voltronic UPS Galleon III 33/31/11 10K-20K is certified to CE, EN 62040-1, IEC 62040-1 and EN 62040-2 and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz, Current Crest Ratio of 3:1 (max.) / 3:1 (max.) and Harmonic Distortion of ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load).

Models and prices

Technical Specifications

Technical Specifications
ParameterVOLTRONIC-GALLEON-III-33-31-11-10K-20K
Bypass
Nominal Voltage3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
Overload Capacity> 130% : 1 minute (default), continuously working until breaker protection (optional) / > 130% : 1 minute (default), continuously working until breaker protection (optional)
Input
Voltage Range190-520 VAC @ 50% load; 305-478 VAC @ 100% load / 190-520 VAC @ 50% load; 305-478 VAC @ 100% load
Frequency Range46-54Hz or 56-64Hz / 46-54Hz or 56-64Hz
Power Factor>= 0.99 @ 100% load / >= 0.99 @ 100% load
Harmonic Distortion (THDi)< 4% @ full linear load / < 4% @ full linear load
Output
Output Voltage3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
AC Voltage Regulation (Batt. Mode)± 1% / ± 1%
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.) / 3:1 (max.)
Harmonic Distortion≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load)
Transfer Time0 / 0 ms
Waveform (Batt. Mode)Pure Sinewave / Pure Sinewave
Electrical Data
AC Mode95.5% / 96%
Battery Mode94.5% / 95.5%
Numbers (default)(10+10) pcs / (16+16) pcs
Long-run Model±8-10 / ±16-20
Efficiency
ECO Mode98.5%
Battery
Battery Type12V / 9Ah / 12V / 9Ah
Typical Recharge Time9 hours recover to 90% capacity / 9 hours recover to 90% capacity
Battery Data
Charging Current (max.)1A (default) / 1A (default)
Charging Voltage+/-136.5 VDC / +/-218VDC
Standards
SafetyEN 62040-1:2008/A1:2013;IEC 62040-1:2008/A1:2013;CE low voltage directive
EMCEN 62040-2: 2006(C3) CE EMC directive
Communication
Smart RS-232/USBSupports Windows® family, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
Physical
Standard Dimension, D x W x H (mm)630 x 250 x 826
Long-run Dimension, D x W x H (mm)630 x 250 x 826
Mechanical Data
Model Net Weight (kgs)80 / 133
Long-run Model Net Weight (kgs)25 / 37
Additional Specifications
Weight80 / 133 kg
Operating Conditions
Operation Temperature0-40°C
Operation Humidity<95% and non-condensing
Altitude0 ~ 1500m at full load
Noise LevelLess than 62dB @ 1 Meter / Less than 65dB @ 1 Meter

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Voltronic Inverters: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • True double-conversion
  • Flexible system configuration as 3-in/3-out,: Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
  • DSP technology guarantees high performance
  • Output power factor 1.0
  • Active power factor correction in: Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • ECO mode operation for energy: ECO mode operation for energy saving (ECO)
  • Dual AC inputs
  • Emergency power off function (EPO)
  • Generator compatible
  • Adjustable battery numbers for long-run: Adjustable battery numbers for long-run model
  • Parallel operation up to 4: Parallel operation up to 4 units with common battery

Frequently Asked Questions

What voltage does the Voltronic UPS Galleon III 33/31/11 10K-20K operate on?

The Voltronic UPS Galleon III 33/31/11 10K-20K has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) / 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) and an operating voltage range of 190-520 VAC @ 50% load.

What are the physical dimensions and weight of the Voltronic UPS Galleon III 33/31/11 10K-20K?

The Voltronic UPS Galleon III 33/31/11 10K-20K measures 630 x 250 x 826 and weighs 80 / 133.

What is the operating temperature range of the Voltronic UPS Galleon III 33/31/11 10K-20K?

The Voltronic UPS Galleon III 33/31/11 10K-20K operates across 0-40°C and a humidity range of <95% and non-condensing.

What is the maximum charge current of the Voltronic UPS Galleon III 33/31/11 10K-20K?

The Voltronic UPS Galleon III 33/31/11 10K-20K has a maximum charge current of 1A (default) / 1A (default).

What output waveform does the Voltronic UPS Galleon III 33/31/11 10K-20K produce?

The Voltronic UPS Galleon III 33/31/11 10K-20K produces a Pure Sinewave / Pure Sinewave output waveform.

How does the Voltronic UPS Galleon III 33/31/11 10K-20K regulate voltage?

The Voltronic UPS Galleon III 33/31/11 10K-20K provides a voltage regulation of ± 1% / ± 1%.

How loud is the Voltronic UPS Galleon III 33/31/11 10K-20K during operation?

The Voltronic UPS Galleon III 33/31/11 10K-20K has a noise level of Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter during operation.

What is the power quality of the Voltronic UPS Galleon III 33/31/11 10K-20K?

The Voltronic UPS Galleon III 33/31/11 10K-20K has a power factor of >= 0.99 @ 100% load / >= 0.99 @ 100% load and a harmonic distortion of < 4% @ full linear load / < 4% @ full linear load.

What certifications does the Voltronic UPS Galleon III 33/31/11 10K-20K have?

The Voltronic UPS Galleon III 33/31/11 10K-20K is certified to CE, EN 62040-1, IEC 62040-1 and EN 62040-2, meeting recognised international standards for safety and performance.

What warranty coverage is available for the Voltronic UPS Galleon III 33/31/11 10K-20K?

The Voltronic UPS Galleon III 33/31/11 10K-20K is backed by a 2-year manufacturer warranty from Voltronic Power.