Voltronic Power Three-Phase Online UPS GALLEON-III-30K-60K
Discover the Voltronic Power Galleon III 3P/3P 30K~60K Rack with 3x 380/400/415 VAC nominal voltage and precise AC voltage regulation.
Models and prices
- VOLTRONIC-GALLEON-III-30K-60KAED 80,000incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-GALLEON-III-30K-60K |
|---|---|
| Input | |
| Nominal Voltage | 3x 380/400/415 VAC (3Ph+N) |
| Voltage Range | 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load |
| Frequency | 46-54 Hz or 56-64 Hz |
| Power Factor | ≥ 0.99 @ 100% load |
| Output | |
| Output Voltage | 3x 380/400/415 VAC (3Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized Range) | 46-54 Hz or 56-64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time AC mode to Battery mode | 0 ms |
| Transfer Time Inverter to Bypass | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| Overload | 100-110% for 60 min, 110-125% for 10 min, 125%-150% for 1 min; >150% immediately |
| Efficiency | |
| AC Mode | 95.5% |
| ECO Mode | 98.5% |
| Battery Mode | 94.5% |
| Battery | |
| Battery Type | Depending on the applications |
| Battery Numbers | ±16 ~20 (Adjustable) |
| Charging Voltage | +/-(13.65V x N (N=16~20)) |
| Electrical Data | |
| Charging Current (max.) | 1A~12A (Adjustable) / 1A~12A (Adjustable) / 1A~18A (Adjustable) |
| Communication | |
| Smart RS-232/USB | Supports Windows® family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Physical | |
| Dimension, D x W x H (mm) | 680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] |
| Mechanical Data | |
| Net Weight (Kgs) | 32 / 34 / 45 |
| Additional Specifications | |
| Weight | 32 / 34 / 45 |
| Operating Conditions | |
| Operating Temperature | 0-40°C |
| Operating Humidity | < 95 % and non-condensing |
| Noise Level | Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 70dB @ 1 Meter |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True double-conversion
- LCD screen auto-rotation with Rack: LCD screen auto-rotation with Rack position (only for 30KL & 40KL models)
- DSP technology guarantees high performance
- Output power factor 1
- Active power factor correction in: Active power factor correction in all phases
- 50Hz/60Hz frequency converter mode
- ECO mode operation for energy: ECO mode operation for energy saving (ECO)
- Emergency power off function (EPO)
- Generator compatible
- Supports dual AC inputs
- 3-stage extendable charging design for: 3-stage extendable charging design for optimized battery performance
- Adjustable battery numbers for long-run: Adjustable battery numbers for long-run model
Frequently Asked Questions
What voltage does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack operate on?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a nominal voltage of 3x 380/400/415 VAC (3Ph+N) and an operating voltage range of 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load.
What are the physical dimensions and weight of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack measures 680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] and weighs 32 / 34 / 45.
What is the operating temperature range of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack operates across 0-40°C and a humidity range of < 95 % and non-condensing.
What is the maximum charge current of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a maximum charge current of 1A~12A (Adjustable) / 1A~12A (Adjustable) / 1A~18A (Adjustable).
What output waveform does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack produce?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack produces a Pure Sinewave output waveform.
How does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack regulate voltage?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack provides a voltage regulation of ± 1%.
How loud is the Voltronic UPS Galleon III 3P/3P 30K~60K Rack during operation?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a noise level of Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 70dB @ 1 Meter during operation.
What is the power quality of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a power factor of ≥ 0.99 @ 100% load and a harmonic distortion of ≤ 2 % THD (Linear Load).
What warranty coverage is available for the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?
The Voltronic UPS Galleon III 3P/3P 30K~60K Rack is backed by a 2-year manufacturer warranty from Voltronic Power.