Voltronic Power Three-Phase Online UPS GALLEON-II-III

Discover Voltronic Power's Galleon II & III UPS systems with 3P/3P 10-40KVA, offering precise voltage regulation and wide frequency range.

Models Covered: VOLTRONIC-GALLEON-II-III

Manufacturer: Voltronic Power Technology Corp.

Application: The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA is a Three Phase Online UPS with a voltage regulation of ± 1% / N/A / N/A / N/A, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 110-300 VAC ± 3 % @ 50% load. Its output waveform is Pure Sine wave / N/A / N/A / N/A. The unit measures 630 x 250 x 826 / 815 x 300 x 1000 / 815 x 300 x 1000 / 815 x 300 x 1000 and weighs 139 / 207 / 207 / 207. It is rated to operate across 0-40°C / N/A / N/A / N/A, with a humidity tolerance of < 95% and non-condensing / N/A / N/A / N/A. The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Synchronized Range) of 46~54Hz or 56~64Hz / N/A / N/A / N/A, Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50/60 Hz ± 1% / 50/60 Hz ± 1% / 50/60 Hz ± 1% and Current Crest Ratio of 3:1 (max.) / N/A / N/A / N/A.

Models and prices

Technical Specifications

Technical Specifications
ParameterVOLTRONIC-GALLEON-II-III
Input
Nominal Voltage3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N)
Voltage Range110-300 VAC ± 3 % @ 50% load; 176-276 VAC ± 3 % @ 100% load / 305VAC~457VAC / 305VAC~457VAC / 305VAC~457VAC
Frequency Range46-54 Hz or 56-64Hz / 40-70 Hz / 40-70 Hz / 40-70 Hz
Power Factor> 0.99 @ 100% Load / N/A / N/A / N/A
Harmonic Distortion (THDi)< 4% at full linear load / N/A / N/A / N/A
Output
AC Voltage Regulation (Batt. Mode)± 1% / N/A / N/A / N/A
Frequency Range (Synchronized Range)46~54Hz or 56~64Hz / N/A / N/A / N/A
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50/60 Hz ± 1% / 50/60 Hz ± 1% / 50/60 Hz ± 1%
Current Crest Ratio3:1 (max.) / N/A / N/A / N/A
Harmonic Distortion≤ 2% THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) / N/A / N/A / N/A
Transfer TimeZero / N/A / N/A / N/A
Waveform (Batt. Mode)Pure Sine wave / N/A / N/A / N/A
Overload AC Mode100-110% for 60 min, 111-125% for 10 min, 126%-150% for 1 min; >150% immediately shutdown / N/A / N/A / N/A
Efficiency
AC Mode95.5% / N/A / N/A / N/A
ECO Mode98.5% / N/A / N/A / N/A
Electrical Data
Battery Mode94.5%
Battery
Battery Type12V/9Ah / N/A / N/A / N/A
Numbers(10+10) pcs / (16+16) pcs x 2 / (16+16) pcs x 2 / (16+16) pcs x 2
Standard Model Recharge Time9 hours recover to 90% capacity / N/A / N/A / N/A
Charging Current (max.)1A (Default) / 2A (Default) / 2A (Default) / 2A (Default)
Charging Voltage+/-136.5 VDC / +/-218 VDC / +/-218 VDC / +/-218 VDC
Communication
Smart RS-232 / USBSupports Windows® Family, Linux and MAC / N/A / N/A / N/A
Optional SNMPPower management from SNMP manager and web browser / N/A / N/A / N/A
Physical
Standard Model Dimension, DxWxH (mm)630 x 250 x 826 / 815 x 300 x 1000 / 815 x 300 x 1000 / 815 x 300 x 1000
Net Weight (kgs)139 / 207 / 207 / 207
Additional Specifications
Weight139 / 207 / 207 / 207
Operating Conditions
Operation Temperature0-40°C / N/A / N/A / N/A
Operation Humidity< 95% and non-condensing / N/A / N/A / N/A
Altitude0 – 1500m at full load / N/A / N/A / N/A

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Voltronic Inverters: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • True double-conversion
  • DSP technology guarantees high performance
  • Output power factor 1
  • Active power factor correction in: Active power factor correction in all phases
  • 50Hz/60Hz frequency converter mode
  • Dual AC inputs
  • Emergency power off function (EPO)
  • Generator compatible
  • Adjustable battery numbers for long-run: Adjustable battery numbers for long-run model
  • Maintenance bypass available
  • Parallel operation up to 4: Parallel operation up to 4 units with common battery
  • Optional isolation transformer offers full: Optional isolation transformer offers full isolation and complete common mode noise rejection

Frequently Asked Questions

What voltage does the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA operate on?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA has a nominal voltage of 3 x 400 VAC (3Ph+N) / 230 VAC (1Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) / 3 x 360/380/400/415 VAC (3Ph+N) and an operating voltage range of 110-300 VAC ± 3 % @ 50% load.

What are the physical dimensions and weight of the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA measures 630 x 250 x 826 / 815 x 300 x 1000 / 815 x 300 x 1000 / 815 x 300 x 1000 and weighs 139 / 207 / 207 / 207.

What is the operating temperature range of the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA operates across 0-40°C / N/A / N/A / N/A and a humidity range of < 95% and non-condensing / N/A / N/A / N/A.

What is the maximum charge current of the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA has a maximum charge current of 1A (Default) / 2A (Default) / 2A (Default) / 2A (Default).

What output waveform does the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA produce?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA produces a Pure Sine wave / N/A / N/A / N/A output waveform.

How does the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA regulate voltage?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA provides a voltage regulation of ± 1% / N/A / N/A / N/A.

What is the power quality of the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA has a power factor of > 0.99 @ 100% Load / N/A / N/A / N/A and a harmonic distortion of < 4% at full linear load / N/A / N/A / N/A.

What warranty coverage is available for the Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA?

The Voltronic UPS Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA is backed by a 2-year manufacturer warranty from Voltronic Power.