Voltronic Galleon One 48V
Discover the Galleon One 48V Online UPS by Voltronic Power with 230 VAC output and wide voltage range for reliable power protection.
- Voltage: 230 VAC
- Voltage Range: 110-280 VAC
- Power Factor: >= 0.98
In stock
Voltronic Galleon One 48V features
About the Voltronic Galleon One 48V
Introducing the Galleon One 48V Online UPS from Voltronic Power, designed to deliver exceptional power protection with a 230 VAC output and a wide voltage range of 110-280 VAC. This UPS ensures stability and reliability for your critical systems. Ideal for data centers, telecommunications, and industrial applications, the Galleon One 48V provides seamless power backup and protection against voltage fluctuations.
Specifications last updated 27 March 2026
Voltronic Galleon One 48V full specifications
Electrical
| Voltage | 230 VAC |
|---|---|
| Voltage Range | 110-280 VAC |
| Frequency Range | 46–54 Hz or 56–64 Hz |
| Power Factor | ≥ 0.98 @ Nominal Voltage (100% Load) |
| THDi | ≤ 10% |
| Output Voltage | 230 VAC ± 5% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
| Harmonic Distortion | ≤ 3% THD (Linear Load), ≤ 5% THD (Non-linear Load) |
| Transfer Time | 0ms |
| Inverter to Bypass | 4 ms (Typical) |
| Waveform | Pure Sinewave |
| Line Mode | 93% |
| ECO Mode | 98% |
| Battery Mode | 93% |
| Battery Voltage | 48 VDC |
| Operating Voltage Range | 40–66 VDC |
| Floating Charge Voltage | 54 VDC |
| Overcharge Protection | 66 VDC |
| Charging Current (max.) | 60 A |
| Communication Interface | RS232 & USB |
Mechanical
| Dimension, D x W x H(mm) | 450 x 190 x 336 |
|---|---|
| Net Weight (kgs) | 14 / 15 |
| Weight | 14 / 15 |
Environmental
| Humidity | 0 to 95% Relative Humidity(Non-condensing) |
|---|---|
| Operating Temperature | 0°C to 50°C |
| Storage Temperature | -15°C to 60°C |
Related Products


Galleon III Rack/Tower
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III 1KVA-3KVA
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III Tower RT 1-3K
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC




Galleon One LiFePO4 RT
- Voltage:100-240 VAC
- Voltage Range:55-300 VAC
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →