Discover the Galleon One RT by Voltronic Power, an online UPS with nominal voltage options from 100 to 240 VAC and precise voltage regulation.
- Nominal Voltage: 100-240 VAC
- Voltage Range: 85-300 VAC
- Power Factor: > 0.99
In stock
Voltronic Galleon One RT features
About the Voltronic Galleon One RT
The Galleon One RT by Voltronic Power is a cutting-edge online UPS designed to deliver reliable power protection. With a wide range of nominal voltage options and precise voltage regulation, it ensures your critical systems remain operational under any conditions. Ideal for data centers, telecommunications, and industrial applications, the Galleon One RT provides seamless power backup and protection against voltage fluctuations.
Specifications last updated 27 March 2026
Voltronic Galleon One RT full specifications
Electrical
| Nominal Voltage | 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 208/220/230/240 VAC / 208/220/230/240 VAC |
|---|---|
| Voltage Range | 85-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load / 85-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load / 85-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load / 85-150 VAC ± 5% or 110-300 VAC ± 5% @ 50% load / 110-300VAC ± 3% @ 50% load; 176-300VAC ± 3% @ 100% load / 110-300VAC ± 3% @ 50% load; 176-300VAC ± 3% @ 100% load |
| Frequency Range | 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Power Factor | > 0.99 @ nominal voltage (100% load) / > 0.99 @ nominal voltage (100% load) / > 0.99 @ nominal voltage (100% load) / > 0.99 @ nominal voltage (100% load) / ≥ 0.99 @ full load / ≥ 0.99 @ full load |
| Output Voltage | 100*/110*/115*/120*/127 VAC or 200*/208/220/230/240 VAC / 100*/110*/115*/120*/127 VAC or 200*/208/220/230/240 VAC / 100*/110*/115*/120*/127 VAC or 200*/208/220/230/240 VAC / 100*/110*/115*/120*/127 VAC or 200*/208/220/230/240 VAC / 208*/220/230/240 VAC / 208*/220/230/240 VAC |
| AC Voltage Regulation | ± 1% / ± 1% / ± 1% / ± 1% / ± 1% / ± 1% |
| Frequency Range (Synchronized Range) | 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 57 ~ 63 Hz or 47 ~ 53 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Waveform (Batt. Mode) | Pure Sinewave |
| AC Mode | ≥ 89% @ full charged battery / ≥ 89% @ full charged battery / ≥ 89% @ full charged battery / ≥ 89% @ full charged battery / 94% / 94% |
| Battery Mode | ≥ 88% / ≥ 88% / ≥ 88% / ≥ 88% / 92% / 92% |
| Battery Type | 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah |
| Numbers | 2 / 3 / 4 / 6 / 16 / 16 |
| Charging Current | 2A / 2A / 2A / 2A / 1.0A / 1.0A |
Mechanical
| Dimension, D x W x H (mm) | 410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88 / 610 x 438 x 88 [2U] / 610 x 438 x 88 [2U] |
|---|---|
| Net Weight (kg) | 11.6 / 14.1 / 15.5 / 19.5 / 17 / 20 |
| Weight | 11.6 / 14.1 / 15.5 / 19.5 / 17 / 20 |
Environmental
| Humidity | 20-90 % RH @ 0-40°C (non-condensing) |
|---|---|
| Noise Level | Less than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 55dB @ 1 Meter |
Certifications
- cTUVus (comply to UL1778)
- FCC
Related Products



Galleon One LiFePO4 RT
- Voltage:100-240 VAC
- Voltage Range:55-300 VAC

Galleon III Rack/Tower
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III 1KVA-3KVA
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III Tower RT 1-3K
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →