
Voltronic Galleon III
Discover the Galleon III UPS by Voltronic Power with 208-240 VAC output and precise voltage regulation for reliable power protection.
- Nominal Voltage: 208-240 VAC
- Voltage Range: 110-300 VAC
- Power Factor: ≥ 0.99
In stock
Voltronic Galleon III features
About the Voltronic Galleon III
The Galleon III by Voltronic Power is a state-of-the-art UPS designed to deliver reliable power protection with a nominal voltage range of 208 to 240 VAC. It ensures precise voltage regulation and frequency stability, making it an ideal choice for sensitive electronic equipment. The Galleon III is perfect for safeguarding critical systems in data centers, telecommunications, and industrial applications, ensuring uninterrupted power supply and protection against voltage fluctuations.
Specifications last updated 27 March 2026
Voltronic Galleon III full specifications
Electrical
| Nominal Voltage | 208/220/230/240 VAC / 208/220/230/240 VAC |
|---|---|
| Voltage Range | 110~300VAC ± 3% at 60% load; 176~300VAC ± 3% at 100% load / 110~300VAC ± 3% at 60% load; 176~300VAC ± 3% at 100% load |
| Frequency Range | 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Power Factor | ≥ 0.99 @ full load / ≥ 0.99 @ full load |
| THDi | < 4% @100% R load / < 4% @100% R load |
| Output Voltage | 208/220/230/240 VAC / 208/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) / 3:1 (max.) |
| Harmonic Distortion | ≤ 1 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) / ≤ 1 % THD (Linear Load) ; ≤ 4 % THD (Non-linear Load) |
| Transfer Time | 0 / 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave / Pure Sinewave |
| Overload | 100-110% for 60 min, 110-125% for 10 min, 125%-150% 1min, >150% immediately switch to bypass / 100-110% for 60 min, 110-125% for 10 min, 125%-150% 1min, >150% immediately switch to bypass |
| AC Mode | 95% / 95% |
| Battery Mode | 92% / 92% |
| Battery Type | 12 V / 7 Ah / 12 V / 9 Ah |
| Numbers | 16 / 20 |
| Typical Recharge Time | 7 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Charging Current (max.) | 1 A ± 10% (Default) / 1 A ± 10% (Default) |
| Charging Voltage | 218.4 VDC ± 1% / 240 VDC ± 1% |
| Standard RS-232/USB | Supports Windows® Family, Linux and MAC / Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser / Power management from SNMP manager and web browser |
| Battery Mode | 92% |
Mechanical
| Dimension, D×W×H (mm) | 369 × 190 × 688 / 442 × 190 × 688 |
|---|---|
| Net Weight (kgs) | 55 / 74 |
| Weight | 55 / 74 |
Environmental
| Operating Humidity | <95 % RH @ 0- 40°C (Non-condensing) / <95 % RH @ 0- 40°C (Non-condensing) |
|---|---|
| Noise Level | Less than 55dB @1Meter / Less than 55dB @1Meter |
Certifications
- ROHS
Related Products

Galleon III Rack/Tower
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III 1KVA-3KVA
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III Tower RT 1-3K
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC





Galleon One LiFePO4 RT
- Voltage:100-240 VAC
- Voltage Range:55-300 VAC
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →