Voltronic Power Galleon One LiFePO4 RT

Voltronic Galleon One LiFePO4 RT

Discover the Galleon One LiFePO4 RT UPS by Voltronic Power with versatile voltage options and precise AC regulation for reliable power.

  • Voltage: 100-240 VAC
  • Voltage Range: 55-300 VAC
  • Power Factor: >= 0.99
4,200 AEDincl. VAT
Full Specifications

Features

True double-conversion

Generator compatible

Output power factor 0.9

Fast battery recharge time

Charging current is selectable through

Charging current is selectable through LCD

Input power factor correction

More than 8 min full

More than 8 min full load backup time

Easy battery replacement design

Long battery lifecycle > 2000

Built-in protection circuit in battery

Built-in protection circuit in battery pack with UL 1973 (MH63914) certified

UN38.3 for battery transportation

Overview

The Galleon One LiFePO4 RT by Voltronic Power is a cutting-edge UPS solution designed to deliver exceptional power reliability. With a wide range of nominal and output voltage options, this UPS ensures seamless operation across various applications, maintaining precise AC voltage regulation even in battery mode. Ideal for critical systems requiring uninterrupted power, such as data centers, telecommunications, and industrial automation, ensuring consistent performance.

Full specifications

Electrical

Nominal Voltage100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC
Voltage Range55~150 VAC ± 3% or 110~300 VAC ± 3% at 50% load; 80~150 VAC ± 3% or 160~300 VAC ± 3% at 100% load / 55~150 VAC ± 3% or 110~300 VAC ± 3% at 50% load; 80~150 VAC ± 3% or 160~300 VAC ± 3% at 100% load / 55~150 VAC ± 3% or 110~300 VAC ± 3% at 50% load; 80~150 VAC ± 3% or 160~300 VAC ± 3% at 100% load / 55~150 VAC ± 3% or 110~300 VAC ± 3% at 50% load; 80~150 VAC ± 3% or 160~300 VAC ± 3% at 100% load
Frequency Range40Hz ~ 70Hz
Power Factor≥ 0.99 @ nominal voltage (100% load)
THDi≤ 5% @ nominal input voltage
Output Voltage100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC / 100/110/115/120/127 VAC or 200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)57~63Hz or 47~53 Hz
Frequency Range (Batt. Mode)60 Hz ± 0.1 Hz or 50Hz ± 0.1 Hz
Current Crest Ratio3:1
Harmonic Distortion≤ 2% THD (Linear Load) ; ≤ 4% THD (Non-linear Load)
Transfer Time0 ms
Inverter to Bypass<4 ms (Typical)
ECO to Battery Mode8 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
AC Mode89% @ full charged battery / 89% @ full charged battery / 90% @ full charged battery / 90% @ full charged battery
ECO Mode≥ 96% @ full charged battery
Battery Type*LiFe 247500 / LiFe 485000 / LiFe 485000 / LiFe 722500
Battery Lifecycle> 2000
Single Cell TypeLFP26650P-260
Battery Numbers*1 / 1 / 2 / 3
Battery Cell Configuration8S3P / 15S2P / (15S2P) x 2 / (24S1P) x 3
Battery Voltage25.6V / 48V / 48V / 76.8V
Battery VAH (Factory Setting)7.5Ah / 5Ah / 10Ah / 7.5Ah
Autonomy Time @ Full Load9.5 minutes / 8 minutes / 12 minutes / 9.5 minutes
Charging Voltage28VDC ± 1% / 52.5VDC ± 1% / 52.5VDC ± 1% / 84VDC ± 1%
Charging Current1/2/4/6/8A(max.), adjustable through LCD
Typical Recharge Time1.5 hours recover to 90% capacity
Smart RS-232/USBSupports Windows 2000/2003/XP/Vista/2008/7/8/10, Linux, Unix and MAC
SNMPPower management from SNMP manager and web browser
EMC/SafetyCE (EMC: EN62040-2 C2) for HV models, FCC (Class A) for LV models, Battery Pack comply to UL1973

Mechanical

Dimension, DxWxH(mm)410 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88
Net Weight (kgs)10.8 / 11.6 / 15.2 / 20.5
Weight10.8 / 11.6 / 15.2 / 20.5

Environmental

Operating Humidity20-95 % RH @ 0-40°C (non-condensing)
Noise LevelLess than 50dBA / Less than 50dBA / Less than 55dBA / Less than 55dBA

Certifications

  • CE
  • FCC
  • UL1973

Related Products