Voltronic Galleon III Tower RT 1-3K
Discover the Voltronic Power Galleon III Tower RT 1-3K UPS with USB, RS-232 ports, and optional SNMP slot for reliable power protection.
- Voltage: 200-240 VAC
- Voltage Range: 110-300 VAC
- Power Factor: >= 0.99
In stock
Voltronic Galleon III Tower RT 1-3K features
About the Voltronic Galleon III Tower RT 1-3K
The Voltronic Power Galleon III Tower RT 1-3K is a robust uninterruptible power supply designed to ensure continuous power delivery. Equipped with USB and RS-232 communication ports, and an optional SNMP intelligent slot, it offers versatile connectivity and advanced protection. Ideal for safeguarding critical systems in data centers, telecommunications, and network environments, ensuring uninterrupted operation and data integrity.
Specifications last updated 27 March 2026
Voltronic Galleon III Tower RT 1-3K full specifications
Electrical
| AC input | N/A |
|---|---|
| USB communication port | Yes |
| RS-232 communication port | Yes |
| SNMP intelligent slot | Optional |
| Communication Ports | USB port / RS-232 port / Intelligent slot / Intelligent slot / Intelligent slot / Intelligent slot |
| External Battery Connection | Voltage ≥ 1.25 x battery voltage/set / Current ≥ 50A / Current ≥ 50A / Current ≥ 50A / Current ≥ 50A / Current ≥ 50A |
| Nominal Voltage | 200/208/220/230/240 VAC |
| Input Voltage Range | 110 – 300 VAC / 110 – 300 VAC / 160 – 300 VAC / 160 – 300 VAC / 160 – 300 VAC / 160 – 300 VAC |
| Frequency Range | 40 Hz ~ 70 Hz |
| Power Factor | ≥ 0.99 @ nominal voltage (100% load) |
| THD | ≤ 5% @ nominal voltage (100% load) |
| Output Voltage | 200/208/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 1 Hz / 60Hz ± 0.1 Hz / 60Hz ± 0.1 Hz / 60Hz ± 0.1 Hz / 60Hz ± 0.1 Hz / 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| ECO mode @ full charged battery | 96% / 97% / 97% / 97% / 97% / 97% |
| AC Mode @ full charged battery | 92% / 92% / 92% / 93% / 93% / 94% |
| Battery Mode | 86% / 89% / 89% / 89% / 89% / 91% |
| Battery Type | 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah |
| Numbers | 2 / 3 / 3 / 4 / 6 / 6 |
| Typical Recharge Time | 4 hours recover to 90% capacity for internal battery |
| Charging Current (CC) | 1.5A |
| Charging Voltage (FV) | 27.4VDC ± 1% / 41.0VDC ± 1% / 41.0VDC ± 1% / 54.8VDC ± 1% / 82.2VDC ± 1% / 82.2VDC ± 1% |
| EMC/Safety | CE (EMC: EN62040-2 C2) |
Mechanical
| Dimension, D x W x H (mm) | 282 x 145 x 220 / 397 x 145 x 220 / 397 x 145 x 220 / 397 x 145 x 220 / 421 x 190 x 318 / 421 x 190 x 318 |
|---|---|
| Net Weight (kgs) | 9.8 / 11.4 / 13.8 / 17 / 22.5 / 26.2 |
| Weight | 9.8 / 11.4 / 13.8 / 17 / 22.5 / 26.2 |
Environmental
| Modem/Phone/Network surge protection | Yes |
|---|---|
| Ambient Temperature Range | 0°C to 40°C |
| Altitude | 1000m |
| Humidity | 20-90 % RH @ 0- 50°C (non-condensing) |
| Noise Level | Less than 50dB(A) @ 1 Meter with Fan speed control |
Certifications
- CE
Related Products

Galleon III Rack/Tower
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III 1KVA-3KVA
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC






Galleon One LiFePO4 RT
- Voltage:100-240 VAC
- Voltage Range:55-300 VAC
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →