Voltronic Victor 1U 6K UPS
Discover the Victor 1U 6K UPS by Voltronic Power with 208-240VAC output and precise voltage regulation of ±1%.
- Voltage: 208-240 VAC
- Voltage Range: 110-300 VAC
- Power Factor: >= 0.99
In stock
Voltronic Victor 1U 6K UPS features
About the Voltronic Victor 1U 6K UPS
The Victor 1U 6K UPS by Voltronic Power is engineered to deliver reliable power protection with a nominal voltage range of 208 to 240VAC. Its robust design ensures consistent performance, making it an ideal choice for critical applications. The Victor 1U 6K UPS is perfect for data centers, telecommunications, and industrial environments where stable power is crucial.
Specifications last updated 27 March 2026
Voltronic Victor 1U 6K UPS full specifications
Electrical
| Nominal Voltage | 208/220/230/240VAC |
|---|---|
| Voltage Range | 110-300VAC ± 3% @ 50% load; 176-300VAC ± 3% @ 100% load |
| Frequency Range | 46-54Hz; 56-64Hz |
| Power Factor | ≥ 0.99 @ nominal voltage (100% load) |
| THDi | ≤ 4% @ 100% load |
| Output Voltage | 208/220/230/240VAC |
| Voltage Regulation | ± 1% |
| Frequency Range (Synchronized Range) | 46-54 Hz or 56-64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz or 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1max |
| Harmonic Distortion | ≤ 2 % THD (Linear Load) / ≤ 4% THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| Overload | AC Mode 100% ≤ load ≤ 105% Warning only; 105%< load ≤ 125%: 1min; >125%: 1 sec |
| AC Mode | 95% (max.) |
| Charging Current | 1A, 2A, 4A (default), 6A |
| Charging Voltage | 219 VDC ± 1% |
| Battery Connector | 2 Poles (50A max.) |
| LCD | Load level, Battery level, AC mode, Battery mode, Bypass mode, and Fault indicators |
| Communication | USB, Communication Slot |
| Battery Mode | 93% (max.) |
| Emergency Power Off (EPO) | YES |
Mechanical
| Dimension, D x W x H (mm) | 520 x 438 x 44 |
|---|---|
| Net Weight (kgs) | 9.8 |
Environmental
| Humidity | 0-95% RH @ 0-40°C (non-condensing) |
|---|---|
| Altitude | 0-2000 meters without derating; 2000-3000 meters derating 1% every 100meters; >3000 meters: not working |
| Noise Level | Less than 55dBA @ 1 Meter |
Related Products






Galleon III Rack/Tower
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III 1KVA-3KVA
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC

Galleon III Tower RT 1-3K
- Voltage:200-240 VAC
- Voltage Range:110-300 VAC
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →