Voltronic CFL UPS
Discover Voltronic Power CFL UPS with 50VA/40W capacity and 230 VAC nominal voltage, ideal for stable power supply.
- Rated Output Power (VA): 50VA
- Rated Output Power (W): 40W
In stock
Voltronic CFL UPS features
About the Voltronic CFL UPS
Introducing the Voltronic Power CFL UPS, a reliable solution for uninterrupted power supply with a capacity of 50VA/40W. Designed to operate within a wide voltage range of 100 VAC to 300 VAC, this UPS ensures your devices remain powered even during outages. The CFL UPS is perfect for small electronic devices, emergency lighting, and home appliances, providing consistent power when you need it most.
Specifications last updated 27 March 2026
Voltronic CFL UPS full specifications
Electrical
| Rated Output Power (VA) | 50VA |
|---|---|
| Rated Output Power (W) | 40W |
| Nominal Voltage | 230 VAC |
| Voltage Range | 100 VAC - 300 VAC |
| Output Voltage (AC Mode) | 100 VDC - 300 VDC |
| Output Voltage (Batt. Mode) | 160-230 VDC ± 10% |
| Waveform (Batt. Mode) | DC Output |
| Battery Type and Numbers | 12V 7Ah x 1 |
| Battery Voltage | 12 VDC |
| Bulk Charging Voltage | 14.5V ±1.5% |
| Floating Voltage | 13.7V ±1.5% |
| Charging Current | 1 A |
| Typical Recharge Time | 6 hours recover to 90% capacity |
| Full battery at Line Mode | Green lighting |
| Charging battery at Line Mode | Green flashing every 2 seconds |
| Normal battery voltage at Battery Mode | Yellow lighting |
| Low battery at Battery Mode | Yellow flashing every second |
| Output short-circuited | Red lighting |
| Overload | Red flashing rapidly every 0.5 second |
| Overcharge | Red LED staying on for one second and off for 4 seconds |
Mechanical
| Dimension, D x W x H (mm) | 209 x 87 x 200 |
|---|---|
| Net Weight (kgs) | 2.7 |
Environmental
| Humidity | 0-90 % RH @ 0-40°C (non-condensing) |
|---|---|
| Noise Level | Less than 40dB |
Related Products







Voltronic SolaPalm 70 UPS
- Nominal Frequency:50/60 Hz (Auto sensing)
- Waveform (Batt. Mode):160-230 VDC ± 10%

Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →