Voltronic Compact 1U
Discover Voltronic Power's Compact 1U UPS with voltage options of 110/120 or 220/230/240 VAC and precise voltage regulation of ±1%.
- Voltage: 110-240 VAC
- Voltage Range: 55-300 VAC
- Power Factor: >= 0.99
Features
Overview
The Compact 1U by Voltronic Power is a reliable UPS solution designed to meet diverse power needs. With voltage options of 110/120 VAC or 220/230/240 VAC, it ensures consistent performance with a voltage regulation of ±1%. Ideal for maintaining power stability in critical applications. The Compact 1U is perfect for data centers, telecommunications, and industrial applications where space is limited but reliable power is essential.
Full specifications
Electrical
| Voltage | 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC / 220/230/240 VAC / 220/230/240 VAC |
|---|---|
| Voltage Range | 55-150 VAC or 110-300 VAC @ 50% load, 80-150 VAC or 160-300 VAC @ 100% load / 110-300 VAC @ 50% load, 160-300 VAC @ 100% load / 55-150 VAC or 110-300 VAC @ 50% load, 80-150 VAC or 160-300 VAC @ 100% load / 110-300 VAC @ 50% load, 160-300 VAC @ 100% load / 110-300 VAC @ 50% load, 160-300 VAC @ 100% load / 110-300 VAC @ 50% load, 160-300 VAC @ 100% load |
| Frequency Range | 40Hz ~ 70Hz |
| Power Factor | >= 0.99 @ nominal voltage (100% load) |
| Output Voltage | 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 220/230/240 VAC / 220/230/240 VAC / 220/230/240 VAC |
| Voltage Regulation | ± 1% |
| Frequency Range (Synchronized Range) | 57 ~ 63 Hz or 47 ~ 53 Hz |
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ± 0.3 Hz |
| Current Crest Ratio | 5:1 (110/120 VAC), 3:1 (220/230/240 VAC) / 3:1 / 5:1 (110/120 VAC), 3:1 (220/230/240 VAC) / 3:1 / 3:1 / 3:1 |
| Harmonic Distortion | ≤ 3% THD (Linear Load); ≤ 5% THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Time (Inverter to Bypass) | 4 ms (Typical) |
| Waveform (Batt. Mode) | Pure Sinewave |
| AC Mode | 86% / 90% / 92% / 93% / 94% / 94% |
| ECO Mode | 96% / 96% / 96% / 96% / 96% / 96% |
| Battery Type | Lithium-ion battery / Sealed Lead-acid battery / Lithium-ion battery or Sealed Lead-acid battery / Lithium-ion battery / Lithium-ion battery / Lithium-ion battery |
| Battery Voltage | 25.6 VDC / 24 VDC / 48 VDC / 38.4 VDC / 48VDC / 48VDC |
| Battery Spec & Numbers | 25.6V/8Ah x 1 / 6V/9Ah x 4 / Depending on external battery capacity / 38.4 V/6Ah x 1 / 48V/5Ah x 1 (additional battery pack expandable) / Depending on external battery capacity |
| Typical Recharge Time | 6 hours recover to 90% capacity / 9 hours recover to 90% capacity / 4 hours recover to 90% capacity / 3.5 hours recover to 90% capacity / 2 hours recover to 90% capacity / 2 hours recover to 90% capacity |
| Charging Current | 1A / 1.5A / 1.5A / 2.5A/5A/7.5A (adjustable via BMS) / 2.5A/5A/7.5A (adjustable via BMS) / 2.5A/5A/7.5A (adjustable via BMS) |
| LED | AC mode, Battery mode and fault indicators |
| Alarm | Battery Mode: Sounding every 4 seconds / Low Battery: Sounding every second / Overload: Sounding twice every second / Fault: Continuously sounding / Fault: Continuously sounding / Fault: Continuously sounding |
| USB or RS-232 | Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Dry Contact | Signal for AC Power Normal, Battery OK and Fault Alarm |
Mechanical
| Dimension (DxWxH)(mm) | 477 x 438 x 44 / 300 x 438 x 44 / 509 x 438 x 44 / 583 x 438 x 44 / 580 x 438 x 44 / 580 x 438 x 44 |
|---|---|
| Net Weight (kgs) | 12.4 / 12.6 / 12.6 / 12.4 / 18 / 12.4 |
| Weight | 12.4 / 12.6 / 12.6 / 12.4 / 18 / 12.4 |
Environmental
| Humidity | 20-90 % RH @ 0- 50°C (non-condensing) |
|---|---|
| Noise Level | Less than 50dBA @ 1 Meter |
Related Articles
AVR Buying Guide — Protect Your Equipment from Voltage Fluctuations
Complete guide to choosing an automatic voltage regulator (AVR). Learn about VA ratings, voltage ranges, relay vs servo types, and installation.
Read: AVR Buying Guide — Protect Your Equipment from Voltage Fluctuations →AVR vs UPS — When Do You Need Each?
Understand the key differences between AVR and UPS systems. Learn when voltage regulation alone is enough and when you need full battery backup.
Read: AVR vs UPS — When Do You Need Each? →Battery Backup Solutions for Business: A Complete Guide
Explore battery backup options for businesses of all sizes. From small office UPS systems to enterprise-grade power protection with extended runtime.
Read: Battery Backup Solutions for Business: A Complete Guide →