
Voltronic ePower DC UPS
Discover the Voltronic Power ePower DC UPS with a voltage range of 90-264 VAC and 12VDC output, offering reliable surge protection.
- Voltage Range: 90-264 VAC
- Frequency: 50/60 Hz
- Surge Protection: 1.5KV (opt. 6KV)
In stock
Voltronic ePower DC UPS features
About the Voltronic ePower DC UPS
The Voltronic Power ePower DC UPS is engineered to deliver consistent power with a wide voltage range of 90 to 264 VAC. Designed for efficiency, it provides a stable 12VDC output, making it ideal for various applications. The ePower DC UPS is perfect for telecommunications, networking equipment, and other critical systems requiring uninterrupted power supply.
Specifications last updated 27 March 2026
Voltronic ePower DC UPS full specifications
Electrical
| Voltage Range | 90 VAC ~ 264 VAC |
|---|---|
| Frequency | 50 or 60 Hz |
| Surge protection | 1.5KV (Optional K.21 enhanced, 6KV) |
| Voltage | 12VDC ± 5% |
| Max. Power | 25W (2.1A) |
| Battery type | Lithium-ion Battery |
| Capacity | 2600mAh |
| Typical Charging Time | 3 hours recover to 90% capacity |
| Full Battery | Green lighting |
| Battery Mode | Constant flashing on Green LED |
| Battery Discharging | Quick flashing on Green LED |
| Fault | Red lighting |
| Battery | Deep Discharge, Over-charge and Short Circuit Protection |
| Battery Charging | Constant flashing on Green LED |
Mechanical
| Input Plug | Mounted on the housing (NEMA/EU/UK) |
|---|---|
| Output Cable | 1m Length (DC Male Jack, OD 4mm, ID 1.7mm) |
| Dimension, D x W x H (mm) | 68 x 42 x 74 |
| Net Weight (g) | 280 |
Environmental
| Input/Output | Fuse for Short Circuit and Overload Protection |
|---|
Related Products








+Power E 15U-90
- Rated Output Power (VA):90kVA
- Rated Output Power (W):90kW
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →