Voltronic Prime Line Interactive UPS
Discover Voltronic Power's Prime Line Interactive UPS with precise voltage regulation and versatile output options for reliable power.
- Voltage: 110-240 VAC
- Frequency: 50/60 Hz
- Transfer Time: 6ms typ, 10ms max
In stock
Voltronic Prime Line Interactive UPS features
About the Voltronic Prime Line Interactive UPS
The Prime Line Interactive UPS by Voltronic Power offers exceptional performance with its precise voltage regulation and flexible output voltage options. Designed to maintain a stable power supply, it is ideal for safeguarding sensitive electronics against power fluctuations. The Prime Line Interactive UPS is perfect for home offices, small businesses, and critical IT environments, ensuring continuous power and protection for computers, servers, and networking equipment.
Specifications last updated 27 March 2026
Voltronic Prime Line Interactive UPS full specifications
Electrical
| Output Voltage | 110/120 VAC or 220/230/240 VAC |
|---|---|
| AC Voltage Regulation (Batt. Mode) | ± 5% |
| Frequency Range (Batt. Mode) | 50 Hz / 60 Hz ± 1Hz |
| Transfer Time | 6ms typical, 10ms max |
| Waveform (Batt. Mode) | Simulated Sinewave |
| Voltage | 110/120 VAC or 220/230/240VAC |
| Voltage Range | 81-132VAC / 86-142VAC or 162-270VAC / 170-270VAC / 176-270VAC |
| Frequency Range | 50 Hz / 60 Hz ± 5Hz (Auto Sensing) |
| Battery Type & Number | 12 V/7 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 2 / 12 V/9 Ah x 2 / 12 V/9 Ah x 2 |
| Typical Recharge Time | 6-8 hours recover to 90% capacity |
| Optional USB Port | Supports Windows® Family, Linux and MAC |
| Compliance & Standards | 110/120VAC model: cTUVus (standard:UL 1778), FCC Part 15 Class B, ENERGY STAR (USA) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) / 220/230/240VAC model: LVD: EN 62040-1, EMC:EN 62040-2 (Class B) |
Mechanical
| Dimension, D x W x H (mm) | 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 |
|---|---|
| Net Weight (kgs) | 6.1 / 7.1 / 7.8 / 8.5 / 11.1 / 11.6 / 12 |
| Weight | 6.1 / 7.1 / 7.8 / 8.5 / 11.1 / 11.6 / 12 |
Environmental
| Full Protection | Overload, discharge, output short circuit and overcharge protection |
|---|---|
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 40dB / Less than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB / Less than 45dB |
Certifications
- CE
- FCC
- TUV
- ENERGY STAR
Related Products

Amber Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Apex Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Ara Line Interactive Sinewave Gaming UPS
- Voltage:110-240 VAC
- Voltage Range:81-280 VAC

Atlas Line Interactive
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Vesta Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC


Library Line Interactive UPS
- Voltage:220/230 VAC
- Acceptable Voltage Range:140 - 300 VAC

Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →