Voltronic Otima II
Discover the Otima II UPS by Voltronic Power with voltage options from 110 to 240 VAC and precise regulation for reliable power protection.
- Voltage: 110-240 VAC
- Voltage Range: 81-290 VAC
- Frequency Range: 50/60 Hz (Auto sensing)
In stock
Voltronic Otima II features
About the Voltronic Otima II
The Otima II UPS by Voltronic Power is engineered to provide exceptional power protection with its versatile voltage options ranging from 110 to 240 VAC. Designed for both home and office environments, it ensures reliable performance with precise voltage regulation and auto-sensing frequency capabilities. Ideal for safeguarding sensitive electronics, the Otima II UPS is perfect for use in home offices, small businesses, and IT equipment, ensuring uninterrupted power supply and protection against voltage fluctuations.
Specifications last updated 27 March 2026
Voltronic Otima II full specifications
Electrical
| Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 208/220/230/240 VAC / 208/220/230/240 VAC |
|---|---|
| Acceptable Voltage Range | 81-152 VAC or 162-290 VAC / 81-152 VAC or 162-290 VAC / 81-152 VAC or 162-290 VAC / 81-152 VAC or 162-290 VAC / 81-152 VAC or 162-290 VAC / 81-152 VAC or 162-290 VAC / 162-290 VAC / 162-290 VAC |
| Frequency Range | 60/50 Hz (Auto sensing) |
| Output Voltage | 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 110/115/120/127 VAC or 208/220/230/240 VAC / 208/220/230/240 VAC / 208/220/230/240 VAC |
| Voltage Regulation (Batt. Mode) | ±1.5 % (Before battery alarm) |
| Frequency Range (Batt. Mode) | 50 Hz or 60 Hz ± 1 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | 2% max @ 100% linear load, 5% max @ 100% non-linear load (before low battery alarm) |
| Transfer Time | Typical 2-6 ms, 10ms max. |
| Waveform (Batt. Mode) | Pure Sinewave |
| ECO Mode | 97% |
| Buck & Boost Mode | 95% |
| Battery Mode | ≥ 88%, up to 90% @ nominal battery voltage / ≥ 89%, up to 91% @ nominal battery voltage for 110/115/120/127 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC / ≥ 91%, up to 92% @ nominal battery voltage for 208/220/230/240 VAC |
| Battery Type and Quantity | 12 V/7 Ah x 2 / 12 V/9 Ah x 2 / 12 V/7 Ah x 4 / 12 V/9 Ah x 4 / 12 V/7 Ah x 6 / 12 V/9 Ah x 6 / 12 V/10 Ah x 6 / 12 V/10 Ah x 6 |
| Charging Current (max.) | 1.5 A |
| Charging Voltage | 27.4 VDC ± 1% / 54.8 VDC ± 1% / 82.1 VDC ± 1% / 82.1 VDC ± 1% / 82.1 VDC ± 1% / 82.1 VDC ± 1% / 82.1 VDC ± 1% / 82.1 VDC ± 1% |
| Typical Recharge Time | 4 hours recover to 90% capacity |
| LCD Display | AC Mode, Battery Mode, Load Level, Battery Level, Input Voltage, Output Voltage, Overload, Fault and Low Battery |
| Low Battery | Sounding every 2 seconds |
| Overload | Sounding every second |
| Fault | Continuously sounding |
| Smart RS-232/USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
Mechanical
| Standard Dimension, DxWxH (mm) | 410 x 438 x 88 / 510 x 438 x 88 / 630 x 438 x 88 / 397 x 145 x 220 / 455 x 145 x 220 / 421 x 190 x 318 / 421 x 190 x 318 / 421 x 190 x 318 |
|---|---|
| Net Weight (kgs) | 12.9 / 13.4 / 19.5 / 21.5 / 27.7 / 29.3 / 11.7 / 12.1 |
| Weight | 12.9 / 13.4 / 19.5 / 21.5 / 27.7 / 29.3 / 11.7 / 12.1 |
Environmental
| Full Protection | Overload, discharge, and overcharge protection |
|---|---|
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 45dB |
| Altitude | 0-3000m, 10% de-rating for over 1000m |
Related Products


Amber Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Apex Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Ara Line Interactive Sinewave Gaming UPS
- Voltage:110-240 VAC
- Voltage Range:81-280 VAC

Atlas Line Interactive
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Prime Line Interactive UPS
- Voltage:110-240 VAC
- Frequency:50/60 Hz

Vesta Line Interactive UPS
- Voltage:110-240 VAC
- Voltage Range:81-290 VAC

Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →