- Voltage: 100-240 VAC
- Voltage Range: 55-300 VAC
- Power Factor: >= 0.99
In stock
Voltronic Winner Pro RT features
About the Voltronic Winner Pro RT
The Winner Pro RT by Voltronic Power is a cutting-edge UPS solution designed to deliver exceptional power protection. With a wide range of nominal voltages and precise voltage regulation of ±1%, this UPS ensures your critical systems remain operational under any condition. Ideal for data centers, telecommunications, and industrial applications, the Winner Pro RT provides reliable backup power to safeguard sensitive equipment from power disturbances.
Specifications last updated 27 March 2026
Voltronic Winner Pro RT full specifications
Electrical
| Nominal Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC / 100/110/115/120/127VAC or 200/208/220/230/240VAC / 100/110/115/120/127VAC or 200/208/220/230/240VAC |
|---|---|
| Input Voltage Range | 55-145 VAC or 110-300 VAC at 50% load; 85-140 VAC or 160-280 VAC at 100% load / 55-145 VAC or 110-300 VAC at 50% load; 85-140 VAC or 160-280 VAC at 100% load / 55-145 VAC or 110-300 VAC at 50% load; 85-140 VAC or 160-280 VAC at 100% load |
| Frequency Range | 40Hz ~ 70 Hz |
| Power Factor | >= 0.99 @ Nominal Voltage (100% load) |
| Output Voltage | 100/110/115/120/127VAC or 200/208/220/230/240VAC / 100/110/115/120/127VAC or 200/208/220/230/240VAC / 100/110/115/120/127VAC or 200/208/220/230/240VAC |
| Voltage Regulation | ±1% |
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | ≤ 3 % THD (Linear Load), ≤ 6 % THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave |
| AC Mode | 88% / 89% / 90% |
| Battery Mode | 83% / 87% / 88% |
| Battery Type | 12 V / 9 AH / 12 V / 9 AH / 12 V / 9 AH |
| Numbers | 2 / 4 / 6 |
| Typical Recharge Time | 4 hours recover to 90% capacity |
| Charging Current | 1.0A / 1.0A/2.0A/4.0A/6.0A / 1.0A/2.0A/4.0A/6.0A |
| Charging Voltage | 27.4VDC ± 1% / 54.7 VDC ±1% / 82.1 VDC ±1% |
| Low Battery | Sounding every second |
| Overload | Sounding twice every second |
| Fault | Continuously sounding |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Battery Mode | 83% |
Mechanical
| Dimension (D x W x H) (mm) | 310 x 438 x 88 [2U] / 410 x 438 x 88 [2U] / 630 x 438 x 88 [2U] |
|---|---|
| Net Weight (kgs) | 12 / 19 / 29.3 |
| Weight | 12 / 19 / 29.3 |
Environmental
| Humidity | 20-90 % RH @ 0- 40°C (non-condensing) |
|---|---|
| Noise Level | Less than 50dB @ 1 Meter |
Related Products

Winner Pro Value 1K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…

Winner Pro Value 2K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…

Winner Pro Value 3K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…



Winner Pro 3P/1P
- Nominal Voltage:3x 400 VAC
- Voltage Range:190-520 VAC


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →