- Nominal Voltage: 110-240 VAC
- Input Voltage Range: 85-300 VAC
- Power Factor: > 0.99
In stock
Voltronic Winner Pro features
About the Voltronic Winner Pro
The Winner Pro by Voltronic Power is an advanced Online UPS designed to deliver exceptional power protection with a nominal voltage range of 110/115/120/127VAC or 208/220/230/240VAC. With a wide input voltage range and precise voltage regulation, it ensures your critical systems remain operational under any condition. Ideal for data centers, telecommunications, and critical IT infrastructure, the Winner Pro provides seamless power backup and protection against voltage fluctuations.
Specifications last updated 27 March 2026
Voltronic Winner Pro full specifications
Electrical
| Nominal Voltage | 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 208/220/230/240VAC / 208/220/230/240VAC |
|---|---|
| Input Voltage Range | 85-140VAC or 160-280VAC (Based on load at 100%) / 85-140VAC or 160-280VAC (Based on load at 100%) / 85-140VAC or 160-280VAC (Based on load at 100%) / 176-300VAC (Based on load at 100%) / 176-300VAC (Based on load at 100%) |
| Frequency Range | 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Power Factor | > 0.99 @ Nominal Voltage (100% load) |
| Output Voltage | 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 208/220/230/240VAC / 208/220/230/240VAC |
| Voltage Regulation | ± 1% |
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz / 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz / 50 Hz ± 0.25 Hz or 60Hz ± 0.3 Hz / 50 Hz or 60Hz ± 0.1 Hz / 50 Hz or 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | ≤ 3 % THD (Linear Load) / ≤ 3 % THD (Linear Load) / ≤ 3 % THD (Linear Load) / ≤ 5 % THD (Non-linear Load) / ≤ 5 % THD (Non-linear Load) |
| Transfer Time AC Mode to Battery Mode | 0 ms |
| Time Interval to Bypass | 4 ms (Typical) / 4 ms (Typical) / 4 ms (Typical) / Zero / Zero |
| Waveform (Batt. Mode) | Pure Sinewave |
| AC Mode | 88% / 89% / 90% / 92% / 93% |
| Battery Mode | 83% / 87% / 88% / 90% / 91% |
| Battery Type | 12 V / 9 Ah |
| Numbers | 2 / 2 / 3 / 16 / 20 |
| Standard Model Typical Recharge Time | 4 hours recover to 90% capacity / 4 hours recover to 90% capacity / 4 hours recover to 90% capacity / 9 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Charging Current (max.) | 1 A / 1 A / 1 A / 1 A / 2 A / 1 A / 2 A |
| Charging Voltage | 27.4VDC ± 1% / 54.7 VDC ± 1% / 82.1 VDC ± 1% / 218.4 VDC ± 1% / 273 VDC ± 1% |
| Long-run Model Numbers | 2 / 3 / 4 / 8 / 16 |
| Long-run Model Charging Current (max.) | 1A/2A/4A/6A (Adjustable) / 1A/2A/4A/6A (Adjustable) / 1A/2A/4A/6A (Adjustable) / 1A/2A/4A/6A (Adjustable, 6A is only available for 16pcs batteries) / 1A/2A/4A/6A (Adjustable, 6A is only available for 20pcs batteries) |
| Smart RS-232 / USB | Supports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
Mechanical
| Dimension D x W x H (mm) | 282 x 145 x 220 / 397 x 145 x 220 / 421 x 190 x 318 / 369 x 190 x 688 / 442 x 190 x 688 |
|---|---|
| Net Weight (kgs) | 9.8 / 17 / 27.6 / 62 / 76 |
| Weight | 9.8 / 17 / 27.6 / 62 / 76 |
Environmental
| Humidity | 20-90 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) / 20-90 % RH @ 0- 40°C (Non-condensing) / 0-95% RH @ 0-50°C (Non-condensing) / 0-95% RH @ 0-50°C (Non-condensing) |
|---|---|
| Noise Level | Less than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter |
Related Products


Winner Pro Value 1K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…

Winner Pro Value 2K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…

Winner Pro Value 3K
- Nominal Voltage:100/110/115/120/127VAC or 200/208/220/230/240VAC
- Input Voltage Range:85-150 VAC or 110-300 VAC (Based on load at 50%) 85-140VAC…


Winner Pro 3P/1P
- Nominal Voltage:3x 400 VAC
- Voltage Range:190-520 VAC


Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →