UPSModel
Voltronic UPS Galleon III 33/31/11 10KL-20KL RT
Discover the Voltronic Power Galleon III 33/31/11 10KL-20KL RT UPS with 3-phase 380/400/415VAC and precise voltage regulation for reliable power.
- Voltage: 220-415 VAC
- Voltage Range: 190-520 VAC (3P)
- Power Factor: >= 0.99
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Voltronic UPS Galleon III 33/31/11 10KL-20KL RT features
Rack/Tower design
Flexible system configuration as 3-in/3-out,
Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
DSP technology guarantees high performance
Output power factor 1
Active power factor correction in
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode operation for energy
ECO mode operation for energy saving (ECO)
Emergency power off function (EPO)
Dual AC inputs
Generator compatible
Adjustable battery numbers
Parallel operation up to 4
Parallel operation up to 4 units with common battery
About the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is a Three Phase Online UPS with a voltage regulation of ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 190-520 VAC (3-phase) @ 50% load. Its output waveform is Pure Sine Wave. The unit measures 620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U] and weighs 16 / 22.2 / 23.1. It is rated to operate across 0-40°C, with a humidity tolerance of <95% and non-condensing. The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz, Current Crest Ratio of 3:1 (max.) and Transfer Time of 0.
Specifications last updated 23 July 2026
Voltronic UPS Galleon III 33/31/11 10KL-20KL RT full specifications
Electrical(20)
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
|---|---|
| Voltage Range | 190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load |
| Frequency Range | 46-54 Hz or 56-64 Hz |
| Power Factor | >= 0.99 @ 100% load |
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 0 ms |
| Waveform (Batt. Mode) | Pure Sine Wave |
|---|---|
| AC Mode | 95.5% / 96% / 96% |
| ECO Mode | 98.5% |
| Battery Mode | 94.5% / 95.5% / 95.5% |
| Battery Type | Depending on application |
| Numbers | ±8 ~ ±10 (adjustable) / ±16 ~ ±20 (adjustable) / ±10 ~ ±20 (adjustable) |
| Charging Current (max.) | 1A ~ 18A (adjustable) |
| Charging Voltage (max.) | +/ -13.65V DC x N (N=8~10) / +/ -13.65V x N (N=16~20) / +/ -13.65V x N (N=10~20) |
| Smart RS-232/USB | Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
Mechanical(3)
| Dimension, D X W X H (mm) | 620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U] |
|---|---|
| Net Weight (kgs) | 16 / 22.2 / 23.1 |
| Weight | 16 / 22.2 / 23.1 |
Environmental(3)
| Operation Temperature | 0-40°C |
|---|---|
| Operation Humidity | <95% and non-condensing |
| Noise Level | Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter |
Downloads & support
Frequently Asked Questions
What voltage does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT operate on?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) and an operating voltage range of 190-520 VAC (3-phase) @ 50% load.
What are the physical dimensions and weight of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT measures 620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U] and weighs 16 / 22.2 / 23.1.
What is the operating temperature range of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT operates across 0-40°C and a humidity range of <95% and non-condensing.
What is the maximum charge current of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a maximum charge current of 1A ~ 18A (adjustable).
What output waveform does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT produce?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT produces a Pure Sine Wave output waveform.
How does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT regulate voltage?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT provides a voltage regulation of ± 1%.
How loud is the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT during operation?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a noise level of Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter during operation.
What is the power quality of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a power factor of >= 0.99 @ 100% load and a harmonic distortion of ≤ 2 % THD (Linear Load).
What warranty coverage is available for the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?
The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is backed by a 2-year manufacturer warranty from Voltronic Power.