Voltronic Power Galleon III 33/31/11 10KL-20KL RT

UPSModel

Voltronic UPS Galleon III 33/31/11 10KL-20KL RT

Discover the Voltronic Power Galleon III 33/31/11 10KL-20KL RT UPS with 3-phase 380/400/415VAC and precise voltage regulation for reliable power.

  • Voltage: 220-415 VAC
  • Voltage Range: 190-520 VAC (3P)
  • Power Factor: >= 0.99
AED 30,000incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: free
  • 2-year warranty

Voltronic UPS Galleon III 33/31/11 10KL-20KL RT features

  • True double-conversion

  • Rack/Tower design

  • Flexible system configuration as 3-in/3-out,

    Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out

  • DSP technology guarantees high performance

  • Output power factor 1

  • Active power factor correction in

    Active power factor correction in all phases

  • 50Hz/60Hz frequency converter mode

  • ECO mode operation for energy

    ECO mode operation for energy saving (ECO)

  • Emergency power off function (EPO)

  • Dual AC inputs

  • Generator compatible

  • Adjustable battery numbers

  • Parallel operation up to 4

    Parallel operation up to 4 units with common battery

About the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is a Three Phase Online UPS with a voltage regulation of ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 190-520 VAC (3-phase) @ 50% load. Its output waveform is Pure Sine Wave. The unit measures 620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U] and weighs 16 / 22.2 / 23.1. It is rated to operate across 0-40°C, with a humidity tolerance of <95% and non-condensing. The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz, Current Crest Ratio of 3:1 (max.) and Transfer Time of 0.

Specifications last updated 23 July 2026

Voltronic UPS Galleon III 33/31/11 10KL-20KL RT full specifications

Electrical(20)

Nominal Voltage3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
Voltage Range190-520 VAC (3-phase) @ 50% load; 305-478 VAC (3-phase) @ 100% load
Frequency Range46-54 Hz or 56-64 Hz
Power Factor>= 0.99 @ 100% load
Output Voltage3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N)
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)
Transfer Time0 ms
Waveform (Batt. Mode)Pure Sine Wave
AC Mode95.5% / 96% / 96%
ECO Mode98.5%
Battery Mode94.5% / 95.5% / 95.5%
Battery TypeDepending on application
Numbers±8 ~ ±10 (adjustable) / ±16 ~ ±20 (adjustable) / ±10 ~ ±20 (adjustable)
Charging Current (max.)1A ~ 18A (adjustable)
Charging Voltage (max.)+/ -13.65V DC x N (N=8~10) / +/ -13.65V x N (N=16~20) / +/ -13.65V x N (N=10~20)
Smart RS-232/USBSupports Windows® Family, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

Mechanical(3)

Dimension, D X W X H (mm)620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U]
Net Weight (kgs)16 / 22.2 / 23.1
Weight16 / 22.2 / 23.1

Environmental(3)

Operation Temperature0-40°C
Operation Humidity<95% and non-condensing
Noise LevelLess than 62dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter

Downloads & support

Frequently Asked Questions

What voltage does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT operate on?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) and an operating voltage range of 190-520 VAC (3-phase) @ 50% load.

What are the physical dimensions and weight of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT measures 620 x 438 x 88 [2U] / 620 x 438 x 130.6 [3U] / 620 x 438 x 130.6 [3U] and weighs 16 / 22.2 / 23.1.

What is the operating temperature range of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT operates across 0-40°C and a humidity range of <95% and non-condensing.

What is the maximum charge current of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a maximum charge current of 1A ~ 18A (adjustable).

What output waveform does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT produce?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT produces a Pure Sine Wave output waveform.

How does the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT regulate voltage?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT provides a voltage regulation of ± 1%.

How loud is the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT during operation?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a noise level of Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter during operation.

What is the power quality of the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT has a power factor of >= 0.99 @ 100% load and a harmonic distortion of ≤ 2 % THD (Linear Load).

What warranty coverage is available for the Voltronic UPS Galleon III 33/31/11 10KL-20KL RT?

The Voltronic UPS Galleon III 33/31/11 10KL-20KL RT is backed by a 2-year manufacturer warranty from Voltronic Power.

Customer reviews