Voltronic Power Galleon III Rack/Tower

UPSModel VOLTRONIC-GALLEON-III-RACK

Voltronic UPS Galleon III Rack/Tower

Discover the Galleon III Rack/Tower UPS by Voltronic Power with 200-240 VAC output and precise voltage regulation for reliable power protection.

  • Voltage: 200-240 VAC
  • Voltage Range: 110-300 VAC
  • Power Factor: >= 0.99
AED 3,500incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • 2-year warranty

Voltronic UPS Galleon III Rack/Tower features

  • True double-conversion

  • Microprocessor control optimizes reliability

  • Input power factor correction 0.99

  • Output power factor 1.0

  • 50/60 Hz Frequency Converter Mode

  • Wide input voltage (110 V

    Wide input voltage (110 V – 300 V)

  • ECO mode for energy saving

  • Smart battery charger design to

    Smart battery charger design to optimize battery performance

  • Comprehensive display allows easy monitoring

    Comprehensive display allows easy monitoring and access of UPS status

  • SNMP/USB/RS-232 multiple communications

  • Generator compatible

About the Voltronic UPS Galleon III Rack/Tower

The Voltronic UPS Galleon III Rack/Tower is a Single Phase Online UPS with a voltage regulation of ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 110 – 300 VAC (Based on load at 50%). Its output waveform is Pure Sinewave. The unit measures 310 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 510 x 438 x 88 / 550 x 438 x 88 / 550 x 438 x 88 and weighs 11 / 13.5 / 14.7 / 19 / 23 / 26.7. The Voltronic UPS Galleon III Rack/Tower is certified to CE and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list THD of ≤ 5% @ nominal voltage (100% load), Frequency Range (Synchronized Range) of 47 ~ 53 Hz or 57 ~ 63 Hz and Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz.

Specifications last updated 27 March 2026

Voltronic UPS Galleon III Rack/Tower full specifications

Electrical(24)

Nominal Voltage200/208/220/230/240 VAC
Input Voltage Range110 – 300 VAC (Based on load at 50%)
Frequency Range40 Hz ~ 70 Hz
Power Factor≥ 0.99 @ nominal voltage (100% load)
THD≤ 5% @ nominal voltage (100% load)
Output Voltage200/208/220/230/240 VAC
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)47 ~ 53 Hz or 57 ~ 63 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz
Current Crest Ratio3:1
Harmonic Distortion≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load)
Transfer Time4 ms (Typical)
Waveform (Batt. Mode)Pure Sinewave
ECO mode @ full charged battery96% / 97% / 97% / 97% / 93% / 94%
AC Mode @ full charged battery92% / 92% / 92% / 92% / 91% / 91%
Battery Mode86% / 89% / 89% / 88% / 89% / 91%
Battery Type12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah
Numbers2 / 3 / 3 / 4 / 6 / 6
Typical Recharge Time4 hours recover to 90% capacity for internal battery
Charging Current (CC)1.5A
Charging Voltage (V)27.4VDC ± 1% / 41.0VDC ± 1% / 41.0VDC ± 1% / 54.8VDC ± 1% / 82.2VDC ± 1% / 82.2VDC ± 1%
Smart RS-232 or USBSupports Windows® family, Linux, Unix and MAC
Optional external slotPower management from SNMP manager and web browser
StandardCE (EMC: EN62040-2 C2)

Mechanical(3)

Dimension, D x W x H (mm)310 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 510 x 438 x 88 / 550 x 438 x 88 / 550 x 438 x 88
Net Weight (kgs)11 / 13.5 / 14.7 / 19 / 23 / 26.7
Weight11 / 13.5 / 14.7 / 19 / 23 / 26.7

Environmental(2)

Humidity20-95 % RH @ 0-40°C (non-condensing)
Noise LevelLess than 50dBA @ 1 Meter with Fan speed control

Certifications(1)

  • CE

Downloads & support

Frequently Asked Questions

What voltage does the Voltronic UPS Galleon III Rack/Tower operate on?

The Voltronic UPS Galleon III Rack/Tower has a nominal voltage of 200/208/220/230/240 VAC and an operating voltage range of 110 – 300 VAC (Based on load at 50%).

What are the physical dimensions and weight of the Voltronic UPS Galleon III Rack/Tower?

The Voltronic UPS Galleon III Rack/Tower measures 310 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 510 x 438 x 88 / 550 x 438 x 88 / 550 x 438 x 88 and weighs 11 / 13.5 / 14.7 / 19 / 23 / 26.7.

What is the maximum charge current of the Voltronic UPS Galleon III Rack/Tower?

The Voltronic UPS Galleon III Rack/Tower has a maximum charge current of 1.5A.

What transfer time and output waveform does the Voltronic UPS Galleon III Rack/Tower provide?

The Voltronic UPS Galleon III Rack/Tower has a transfer time of 4 ms (Typical) and an output waveform of Pure Sinewave.

How does the Voltronic UPS Galleon III Rack/Tower regulate voltage?

The Voltronic UPS Galleon III Rack/Tower provides a voltage regulation of ± 1%.

How loud is the Voltronic UPS Galleon III Rack/Tower during operation?

The Voltronic UPS Galleon III Rack/Tower has a noise level of Less than 50dBA @ 1 Meter with Fan speed control during operation.

What is the power quality of the Voltronic UPS Galleon III Rack/Tower?

The Voltronic UPS Galleon III Rack/Tower has a power factor of ≥ 0.99 @ nominal voltage (100% load) and a harmonic distortion of ≤ 2 % THD (Linear Load).

What certifications does the Voltronic UPS Galleon III Rack/Tower have?

The Voltronic UPS Galleon III Rack/Tower is certified to CE, meeting recognised international standards for safety and performance.

What warranty coverage is available for the Voltronic UPS Galleon III Rack/Tower?

The Voltronic UPS Galleon III Rack/Tower is backed by a 2-year manufacturer warranty from Voltronic Power.