Voltronic Power Galleon III 3P/3P 30K~60K Rack

UPSModel VOLTRONIC-GALLEON-III-30K-60K

Voltronic UPS Galleon III 3P/3P 30K~60K Rack

Discover the Voltronic Power Galleon III 3P/3P 30K~60K Rack with 3x 380/400/415 VAC nominal voltage and precise AC voltage regulation.

  • Voltage: 3x 380-415 VAC (3P)
  • Voltage Range: 190-520 VAC (3P)
  • Power Factor: >= 0.99
AED 80,000incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • Delivery charge: free
  • 2-year warranty

Voltronic UPS Galleon III 3P/3P 30K~60K Rack features

  • True double-conversion

  • LCD screen auto-rotation with Rack

    LCD screen auto-rotation with Rack position (only for 30KL & 40KL models)

  • DSP technology guarantees high performance

  • Output power factor 1

  • Active power factor correction in

    Active power factor correction in all phases

  • 50Hz/60Hz frequency converter mode

  • ECO mode operation for energy

    ECO mode operation for energy saving (ECO)

  • Emergency power off function (EPO)

  • Generator compatible

  • Supports dual AC inputs

  • 3-stage extendable charging design for

    3-stage extendable charging design for optimized battery performance

  • Adjustable battery numbers for long-run

    Adjustable battery numbers for long-run model

  • Parallel operation with common battery

About the Voltronic UPS Galleon III 3P/3P 30K~60K Rack

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack is a Three Phase Online UPS with a voltage regulation of ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load. Its output waveform is Pure Sinewave. The unit measures 680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] and weighs 32 / 34 / 45. It is rated to operate across 0-40°C, with a humidity tolerance of < 95 % and non-condensing. The Voltronic UPS Galleon III 3P/3P 30K~60K Rack is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency of 46-54 Hz or 56-64 Hz, Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz and Current Crest Ratio of 3:1 (max.).

Specifications last updated 27 March 2026

Voltronic UPS Galleon III 3P/3P 30K~60K Rack full specifications

Electrical(23)

Nominal Voltage3x 380/400/415 VAC (3Ph+N)
Voltage Range190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load
Frequency46-54 Hz or 56-64 Hz
Power Factor≥ 0.99 @ 100% load
Output Voltage3x 380/400/415 VAC (3Ph+N)
AC Voltage Regulation (Batt. Mode)± 1%
Frequency Range (Synchronized Range)46-54 Hz or 56-64 Hz
Frequency Range (Batt. Mode)50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1 (max.)
Harmonic Distortion≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load)
Transfer Time AC mode to Battery mode0 ms
Transfer Time Inverter to Bypass0 ms
Waveform (Batt. Mode)Pure Sinewave
Overload100-110% for 60 min, 110-125% for 10 min, 125%-150% for 1 min; >150% immediately
AC Mode95.5%
ECO Mode98.5%
Battery TypeDepending on the applications
Battery Numbers±16 ~20 (Adjustable)
Charging Current (max.)1A~12A (Adjustable) / 1A~12A (Adjustable) / 1A~18A (Adjustable)
Charging Voltage+/-(13.65V x N (N=16~20))
Smart RS-232/USBSupports Windows® family, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser
Battery Mode94.5%

Mechanical(3)

Dimension, D x W x H (mm)680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U]
Net Weight (Kgs)32 / 34 / 45
Weight32 / 34 / 45

Environmental(3)

Operating Temperature0-40°C
Operating Humidity< 95 % and non-condensing
Noise LevelLess than 65dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 70dB @ 1 Meter

Downloads & support

Frequently Asked Questions

What voltage does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack operate on?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a nominal voltage of 3x 380/400/415 VAC (3Ph+N) and an operating voltage range of 190-520 VAC (3-phase) @ 50% load, 305-478 VAC (3-phase) @ 100% load.

What are the physical dimensions and weight of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack measures 680 x 438 x 133 [3U] / 680 x 438 x 133 [3U] / 797 x 438 x 176 [4U] and weighs 32 / 34 / 45.

What is the operating temperature range of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack operates across 0-40°C and a humidity range of < 95 % and non-condensing.

What is the maximum charge current of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a maximum charge current of 1A~12A (Adjustable) / 1A~12A (Adjustable) / 1A~18A (Adjustable).

What output waveform does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack produce?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack produces a Pure Sinewave output waveform.

How does the Voltronic UPS Galleon III 3P/3P 30K~60K Rack regulate voltage?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack provides a voltage regulation of ± 1%.

How loud is the Voltronic UPS Galleon III 3P/3P 30K~60K Rack during operation?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a noise level of Less than 65dB @ 1 Meter / Less than 65dB @ 1 Meter / Less than 70dB @ 1 Meter during operation.

What is the power quality of the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack has a power factor of ≥ 0.99 @ 100% load and a harmonic distortion of ≤ 2 % THD (Linear Load).

What warranty coverage is available for the Voltronic UPS Galleon III 3P/3P 30K~60K Rack?

The Voltronic UPS Galleon III 3P/3P 30K~60K Rack is backed by a 2-year manufacturer warranty from Voltronic Power.

Customer reviews