UPSModel VOLTRONIC-GALLEON-III-33-31-11-10K-20K
Voltronic UPS Galleon III 33/31/11 10K-20K
Discover the Voltronic Power Galleon III 33/31/11 10K-20K Online UPS with 3 x 380/400/415VAC voltage, ensuring reliable power protection.
- Nominal Voltage: 3x 380/400/415 VAC
- Voltage Range: 190-520 VAC
- Power Factor: >= 0.99
In stock
- Delivered within 3 business days, door to door, to every market we serve.
- Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
- Delivery charge: free
- 2-year warranty
Voltronic UPS Galleon III 33/31/11 10K-20K features
Flexible system configuration as 3-in/3-out,
Flexible system configuration as 3-in/3-out, 3-in/1-out or 1-in/1-out
DSP technology guarantees high performance
Output power factor 1.0
Active power factor correction in
Active power factor correction in all phases
50Hz/60Hz frequency converter mode
ECO mode operation for energy
ECO mode operation for energy saving (ECO)
Dual AC inputs
Emergency power off function (EPO)
Generator compatible
Adjustable battery numbers for long-run
Adjustable battery numbers for long-run model
Parallel operation up to 4
Parallel operation up to 4 units with common battery
About the Voltronic UPS Galleon III 33/31/11 10K-20K
The Voltronic UPS Galleon III 33/31/11 10K-20K is a Three Phase Online UPS with a voltage regulation of ± 1% / ± 1%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 190-520 VAC @ 50% load. Its output waveform is Pure Sinewave / Pure Sinewave. The unit measures 630 x 250 x 826 and weighs 80 / 133. It is rated to operate across 0-40°C, with a humidity tolerance of <95% and non-condensing. The Voltronic UPS Galleon III 33/31/11 10K-20K is certified to CE, EN 62040-1, IEC 62040-1 and EN 62040-2 and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Batt. Mode) of 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz, Current Crest Ratio of 3:1 (max.) / 3:1 (max.) and Harmonic Distortion of ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load).
Specifications last updated 23 July 2026
Voltronic UPS Galleon III 33/31/11 10K-20K full specifications
Electrical(26)
| Nominal Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
|---|---|
| Voltage Range | 190-520 VAC @ 50% load; 305-478 VAC @ 100% load / 190-520 VAC @ 50% load; 305-478 VAC @ 100% load |
| Frequency Range | 46-54Hz or 56-64Hz / 46-54Hz or 56-64Hz |
| Power Factor | >= 0.99 @ 100% load / >= 0.99 @ 100% load |
| Harmonic Distortion (THDi) | < 4% @ full linear load / < 4% @ full linear load |
| Output Voltage | 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) / 3 x 380/400/415VAC (3Ph+N) or 220/230/240VAC (1Ph+N) |
| AC Voltage Regulation (Batt. Mode) | ± 1% / ± 1% |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 (max.) / 3:1 (max.) |
| Harmonic Distortion | ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) / ≤ 2 % THD (Linear Load); ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 0 / 0 ms |
| Waveform (Batt. Mode) | Pure Sinewave / Pure Sinewave |
| Overload Capacity | > 130% : 1 minute (default), continuously working until breaker protection (optional) / > 130% : 1 minute (default), continuously working until breaker protection (optional) |
| AC Mode | 95.5% / 96% |
|---|---|
| ECO Mode | 98.5% |
| Battery Mode | 94.5% / 95.5% |
| Battery Type | 12V / 9Ah / 12V / 9Ah |
| Numbers (default) | (10+10) pcs / (16+16) pcs |
| Typical Recharge Time | 9 hours recover to 90% capacity / 9 hours recover to 90% capacity |
| Charging Current (max.) | 1A (default) / 1A (default) |
| Charging Voltage | +/-136.5 VDC / +/-218VDC |
| Long-run Model | ±8-10 / ±16-20 |
| Safety | EN 62040-1:2008/A1:2013;IEC 62040-1:2008/A1:2013;CE low voltage directive |
| EMC | EN 62040-2: 2006(C3) CE EMC directive |
| Smart RS-232/USB | Supports Windows® family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
Mechanical(5)
| Standard Dimension, D x W x H (mm) | 630 x 250 x 826 |
|---|---|
| Model Net Weight (kgs) | 80 / 133 |
| Long-run Dimension, D x W x H (mm) | 630 x 250 x 826 |
| Long-run Model Net Weight (kgs) | 25 / 37 |
| Weight | 80 / 133 kg |
Environmental(4)
| Operation Temperature | 0-40°C |
|---|---|
| Operation Humidity | <95% and non-condensing |
| Altitude | 0 ~ 1500m at full load |
| Noise Level | Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter |
Certifications(4)
- CE
- EN 62040-1
- IEC 62040-1
- EN 62040-2
Downloads & support
Frequently Asked Questions
What voltage does the Voltronic UPS Galleon III 33/31/11 10K-20K operate on?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) / 3 x 380/400/415 VAC (3Ph+N) or 220/230/240 VAC (1Ph+N) and an operating voltage range of 190-520 VAC @ 50% load.
What are the physical dimensions and weight of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K measures 630 x 250 x 826 and weighs 80 / 133.
What is the operating temperature range of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K operates across 0-40°C and a humidity range of <95% and non-condensing.
What is the maximum charge current of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a maximum charge current of 1A (default) / 1A (default).
What output waveform does the Voltronic UPS Galleon III 33/31/11 10K-20K produce?
The Voltronic UPS Galleon III 33/31/11 10K-20K produces a Pure Sinewave / Pure Sinewave output waveform.
How does the Voltronic UPS Galleon III 33/31/11 10K-20K regulate voltage?
The Voltronic UPS Galleon III 33/31/11 10K-20K provides a voltage regulation of ± 1% / ± 1%.
How loud is the Voltronic UPS Galleon III 33/31/11 10K-20K during operation?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a noise level of Less than 62dB @ 1 Meter / Less than 65dB @ 1 Meter during operation.
What is the power quality of the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K has a power factor of >= 0.99 @ 100% load / >= 0.99 @ 100% load and a harmonic distortion of < 4% @ full linear load / < 4% @ full linear load.
What certifications does the Voltronic UPS Galleon III 33/31/11 10K-20K have?
The Voltronic UPS Galleon III 33/31/11 10K-20K is certified to CE, EN 62040-1, IEC 62040-1 and EN 62040-2, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Galleon III 33/31/11 10K-20K?
The Voltronic UPS Galleon III 33/31/11 10K-20K is backed by a 2-year manufacturer warranty from Voltronic Power.