Voltronic Power UPS GALLEON-III-RACK
Discover the Galleon III Rack/Tower UPS by Voltronic Power with 200-240 VAC output and precise voltage regulation for reliable power protection.
Models and prices
- VOLTRONIC-GALLEON-III-RACKAED 3,500incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-GALLEON-III-RACK |
|---|---|
| Input | |
| Nominal Voltage | 200/208/220/230/240 VAC |
| Input Voltage Range | 110 – 300 VAC (Based on load at 50%) |
| Frequency Range | 40 Hz ~ 70 Hz |
| Power Factor | ≥ 0.99 @ nominal voltage (100% load) |
| THD | ≤ 5% @ nominal voltage (100% load) |
| Output | |
| Output Voltage | 200/208/220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ± 1% |
| Frequency Range (Synchronized Range) | 47 ~ 53 Hz or 57 ~ 63 Hz |
| Frequency Range (Batt. Mode) | 50 Hz ± 0.1 Hz or 60Hz ± 0.1 Hz |
| Current Crest Ratio | 3:1 |
| Harmonic Distortion | ≤ 2 % THD (Linear Load) ; ≤ 5 % THD (Non-linear Load) |
| Transfer Time | 4 ms (Typical) |
| Waveform (Batt. Mode) | Pure Sinewave |
| Electrical Data | |
| ECO mode @ full charged battery | 96% / 97% / 97% / 97% / 93% / 94% |
| AC Mode @ full charged battery | 92% / 92% / 92% / 92% / 91% / 91% |
| Battery Mode | 86% / 89% / 89% / 88% / 89% / 91% |
| Battery Type | 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah / 12 V / 9 Ah / 12 V / 7 Ah / 12 V / 9 Ah |
| Numbers | 2 / 3 / 3 / 4 / 6 / 6 |
| Charging Voltage (V) | 27.4VDC ± 1% / 41.0VDC ± 1% / 41.0VDC ± 1% / 54.8VDC ± 1% / 82.2VDC ± 1% / 82.2VDC ± 1% |
| Battery | |
| Typical Recharge Time | 4 hours recover to 90% capacity for internal battery |
| Charging Current (CC) | 1.5A |
| Communication | |
| Smart RS-232 or USB | Supports Windows® family, Linux, Unix and MAC |
| Optional external slot | Power management from SNMP manager and web browser |
| Certifications | |
| Standard | CE (EMC: EN62040-2 C2) |
| Mechanical Data | |
| Dimension, D x W x H (mm) | 310 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 510 x 438 x 88 / 550 x 438 x 88 / 550 x 438 x 88 |
| Net Weight (kgs) | 11 / 13.5 / 14.7 / 19 / 23 / 26.7 |
| Additional Specifications | |
| Weight | 11 / 13.5 / 14.7 / 19 / 23 / 26.7 |
| Operating Conditions | |
| Humidity | 20-95 % RH @ 0-40°C (non-condensing) |
| Noise Level | Less than 50dBA @ 1 Meter with Fan speed control |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True double-conversion
- Microprocessor control optimizes reliability
- Input power factor correction 0.99
- Output power factor 1.0
- 50/60 Hz Frequency Converter Mode
- Wide input voltage (110 V: Wide input voltage (110 V – 300 V)
- ECO mode for energy saving
- Smart battery charger design to: Smart battery charger design to optimize battery performance
- Comprehensive display allows easy monitoring: Comprehensive display allows easy monitoring and access of UPS status
- SNMP/USB/RS-232 multiple communications
- Generator compatible
Frequently Asked Questions
What voltage does the Voltronic UPS Galleon III Rack/Tower operate on?
The Voltronic UPS Galleon III Rack/Tower has a nominal voltage of 200/208/220/230/240 VAC and an operating voltage range of 110 – 300 VAC (Based on load at 50%).
What are the physical dimensions and weight of the Voltronic UPS Galleon III Rack/Tower?
The Voltronic UPS Galleon III Rack/Tower measures 310 x 438 x 88 / 410 x 438 x 88 / 510 x 438 x 88 / 510 x 438 x 88 / 550 x 438 x 88 / 550 x 438 x 88 and weighs 11 / 13.5 / 14.7 / 19 / 23 / 26.7.
What is the maximum charge current of the Voltronic UPS Galleon III Rack/Tower?
The Voltronic UPS Galleon III Rack/Tower has a maximum charge current of 1.5A.
What transfer time and output waveform does the Voltronic UPS Galleon III Rack/Tower provide?
The Voltronic UPS Galleon III Rack/Tower has a transfer time of 4 ms (Typical) and an output waveform of Pure Sinewave.
How does the Voltronic UPS Galleon III Rack/Tower regulate voltage?
The Voltronic UPS Galleon III Rack/Tower provides a voltage regulation of ± 1%.
How loud is the Voltronic UPS Galleon III Rack/Tower during operation?
The Voltronic UPS Galleon III Rack/Tower has a noise level of Less than 50dBA @ 1 Meter with Fan speed control during operation.
What is the power quality of the Voltronic UPS Galleon III Rack/Tower?
The Voltronic UPS Galleon III Rack/Tower has a power factor of ≥ 0.99 @ nominal voltage (100% load) and a harmonic distortion of ≤ 2 % THD (Linear Load).
What certifications does the Voltronic UPS Galleon III Rack/Tower have?
The Voltronic UPS Galleon III Rack/Tower is certified to CE, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Galleon III Rack/Tower?
The Voltronic UPS Galleon III Rack/Tower is backed by a 2-year manufacturer warranty from Voltronic Power.