True online double conversion with
True online double conversion with DSP control

Discover the Voltronic Power Giant II 3P/3P UPS with 6 pulse rectifier and 380VAC/400VAC/415VAC nominal voltage for reliable power solutions.
The Voltronic Power Giant II 3P/3P UPS is engineered to deliver robust and reliable power management solutions. With a 6 pulse rectifier and a nominal voltage range of 380VAC to 415VAC, it ensures optimal performance for critical applications. Ideal for data centers, industrial facilities, and telecommunications, the Giant II 3P/3P UPS provides consistent power protection and efficiency.



.jpg&w=2048&q=75&dpl=dpl_2tSqawRX37WYdEfwsRNypYTLRwJ5)
Compare the three UPS topologies: online double-conversion, line-interactive, and standby. Understand transfer times, efficiency, cost, and best uses.
Read more →Compare Voltronic and APC (Schneider Electric) UPS systems. Features, pricing, support, product range, and which brand is right for your application.
Read more →Step-by-step guide to choosing the right UPS. Understand topologies, sizing, battery types, and features to match your exact power protection needs.
Read more →The Giant II 3P/3P UPS features a power factor of 0.9, which can be customized up to 1.0. It operates with a nominal voltage of 380VAC/400VAC/415VAC and maintains output voltage regulation within ±1%.
The UPS is designed to work with a battery voltage of 384 VDC, which is adjustable. It does not directly support solar panels but can be integrated into systems that include solar power with appropriate converters.
The dimensions of the UPS are 656 x 405 x 817 mm. It has an IP31 protection rating by default, with an optional upgrade to IP42 for enhanced protection.
Installation requires a stable environment with an input voltage range of 285VAC to 475VAC. Ensure adequate space for ventilation and maintenance access.
Voltronic Power typically offers a standard warranty period for their UPS products, but specific terms should be confirmed with the retailer or distributor.
The UPS complies with the IEC62040-1:2017 standard, ensuring it meets international safety and performance requirements.
The UPS is designed to operate efficiently within a frequency range of 50Hz ± 10%. It should be used in environments with controlled temperature and humidity to ensure optimal performance.
Key features include a cold start capability and overload capability of 110% continuous running, 125% for 10 minutes, and over 150% for 1 minute. These features ensure reliability and flexibility in power management.