Voltronic Power Three-Phase Online UPS GIANT-II-3P-3P
Discover the Voltronic Power Giant II 3P/3P UPS with 6 pulse rectifier and 380VAC/400VAC/415VAC nominal voltage for reliable power solutions.
Models and prices
- VOLTRONIC-GIANT-II-3P-3PAED 110,000incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-GIANT-II-3P-3P |
|---|---|
| Electrical Data | |
| Rectifier Type | 6 pulse / 6 pulse / 6 pulse / 6 pulse / 6 pulse / 6 pulse / 12 pulse / 12 pulse / 12 pulse / 12 pulse |
| Input | |
| Nominal Voltage | 380VAC/400VAC/415VAC |
| Acceptable Voltage Range | 304VAC – 456VAC |
| Frequency | 50Hz ± 10% |
| TVSS | 40kA (optional) |
| Bypass | |
| Input Voltage Range | 285VAC – 475VAC |
| Battery | |
| Battery Voltage | 384 VDC (adjustable) |
| Cold Start | Yes |
| Output | |
| Power Factor | 0.9, customized up to 1.0 |
| Nominal Output Voltage | 380VAC/400VAC/415VAC |
| Output Voltage Regulation | ±1% |
| Overload Capability | 110% continuous running; 125% for 10 min; >150% for 1 min |
| Communication | |
| Dry Contacts | 5 outputs and 4 inputs |
| Optional SNMP | Power management from SNMP manager and web browser |
| Modbus RS-232/RS-485 | Supports Windows® family, Linux and MAC |
| Certifications | |
| Safety | IEC62040-1:2017 |
| Physical | |
| IP Protection | IP31 (default), IP42 (optional) |
| Dimensions (DxWxH) mm | 656 x 405 x 817 / 656 x 405 x 941 / 818 x 432 x 1159 / 971 x 554 x 1290 / 971 x 635 x 1326 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 |
| Mechanical Data | |
| Net Weight (Kgs) | 120 / 145 / 193 / 278 / 365 / 471 / 573 / 650 / 735 / 790 |
| Additional Specifications | |
| Weight | 120 / 145 / 193 / 278 / 365 / 471 / 573 / 650 / 735 / 790 |
| Operating Conditions | |
| Operating Temperature | 0 – 50°C |
| Storage Temperature | -25°C – 55°C |
| Humidity | 0–95% (non-condensing) |
| Altitude | 1000m |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- True online double conversion with: True online double conversion with DSP control
- Output power factor 0.9, customized: Output power factor 0.9, customized up to 1.0
- Galvanic isolation eliminates common mode: Galvanic isolation eliminates common mode noise
- Conformal coating ensures operation stability
- Standard IP31 protection, optional IP42
- Sustains long-term operation for all: Sustains long-term operation for all types of loads
- Redundant design for reliability
- Temperature compensation to prolong battery: Temperature compensation to prolong battery life
- Backfeed protection guarantees safety operation
- 7” touch color LCD with: 7” touch color LCD with customized control setting
- Accepts dual-mains inputs
- Parallel capability up to 4: Parallel capability up to 4 units
Frequently Asked Questions
What voltage does the Voltronic UPS Giant II 3P/3P operate on?
The Voltronic UPS Giant II 3P/3P has a nominal voltage of 380 VAC/400 VAC/415 VAC and an operating voltage range of 304 VAC – 456 VAC.
What are the physical dimensions and weight of the Voltronic UPS Giant II 3P/3P?
The Voltronic UPS Giant II 3P/3P measures 656 x 405 x 817 / 656 x 405 x 941 / 818 x 432 x 1159 / 971 x 554 x 1290 / 971 x 635 x 1326 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 / 1051 x 705 x 1646 and weighs 120 / 145 / 193 / 278 / 365 / 471 / 573 / 650 / 735 / 790.
What is the operating temperature range of the Voltronic UPS Giant II 3P/3P?
The Voltronic UPS Giant II 3P/3P operates across 0 – 50°C and a humidity range of 0–95% (non-condensing).
How does the Voltronic UPS Giant II 3P/3P regulate voltage?
The Voltronic UPS Giant II 3P/3P provides a voltage regulation of ±1%.
What ingress protection rating does the Voltronic UPS Giant II 3P/3P carry?
The Voltronic UPS Giant II 3P/3P carries an ingress protection rating of IP31 (default), IP42 (optional).
What is the power quality of the Voltronic UPS Giant II 3P/3P?
The Voltronic UPS Giant II 3P/3P has a power factor of 0.9, customized up to 1.0.
What certifications does the Voltronic UPS Giant II 3P/3P have?
The Voltronic UPS Giant II 3P/3P is certified to IEC62040-1:2017, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Giant II 3P/3P?
The Voltronic UPS Giant II 3P/3P is backed by a 2-year manufacturer warranty from Voltronic Power.