Voltronic Fortress 3/3 240K
Discover the Fortress 3/3 240K by Voltronic Power with 3 x 380/400/415 VAC and auto-sensing 50/60Hz frequency for reliable power protection.
- Nominal Voltage: 3x 380/400/415 VAC
- Voltage Range: 110-300 VAC @ 50% load; 184-276 VAC @100% load
- Frequency: 50/60Hz (Auto sensing)
In stock
Voltronic Fortress 3/3 240K features
About the Voltronic Fortress 3/3 240K
The Fortress 3phase UPS from Voltronic Power is engineered to deliver robust and reliable power protection for critical applications. With a nominal voltage of 3 x Fortress 3/3 240K VAC and auto-sensing frequency, it ensures seamless operation across various environments. Ideal for data centers, industrial facilities, and telecommunications, the Fortress 3phase UPS provides consistent power regulation and protection against voltage fluctuations. This model: Fortress 3/3 240K.
Specifications last updated 27 March 2026
Voltronic Fortress 3/3 240K full specifications
Electrical
| Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) |
|---|---|
| Voltage Range | 110-300 VAC @ 50% load; 184-276 VAC @100% load |
| Nominal Frequency | 50/60Hz (Auto sensing) |
| Frequency Range | 40Hz ~ 70Hz |
| Power Factor | >= 0.99 @ 100% load |
| Harmonic Distortion (THDi) | <5% @ 100% load |
| Voltage Regulation (Steady state) | ≤ ± 2% Typical (unbalanced load) |
| Frequency Range (Synchronized range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz |
| Overload Capability | ≤ 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms |
| Harmonic Distortion | ≤ 2% THD (Linear Load); ≤ 4% THD (Non-linear Load) |
| AC Mode | 95.5% |
| ECO Mode | 98.5% |
| Maximum Voltage | +/- 240V (12V x 40 Pcs) |
| Minimum Voltage | +/- 192V (12V x 32 Pcs) |
| Floating Charge Voltage | 2.28V / Cell (2.25 ~ 2.33 Selectable) |
| Boost Charging Voltage | 2.35V/Cell |
| Maximum Charging Current | 72A (Adjustable) |
| Management | Supports Windows® Family, Linux and MAC |
| Optional SNMP | Power management from SNMP manager and web browser |
| Safety | IEC/EN 62040-1 |
| EMC | IEC/EN 62040-2 Category C3 |
| Battery Mode | 94.5% |
Mechanical
| IP Class | IP20, optional IP31 |
|---|---|
| Dimension, D x W x H (mm) | 1100x600x1475 |
| Net Weight (Kgs) | 360 |
| Weight | 360 |
Environmental
| Operating Temperature | 0-40°C |
|---|---|
| Operating Humidity | < 95% and non-condensing |
| Altitude | <1000m for Nominal power |
| Temperature Compensation | Yes |
Certifications
- IEC/EN 62040-1
- IEC/EN 62040-2 Category C3
Related Products

Fortress 3/3 100K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 120K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 180K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 200K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 300K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 60K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Fortress 3/3 80K
- Nominal Voltage:3x 380/400/415 VAC
- Voltage Range:110-300 VAC @ 50% load; 184-276 VAC @100% load

Galleon II 3P/3P 10-20KVA, III 3P/3P 30-40KVA
- Nominal Voltage:3x 360-415 VAC (3Ph+N)
- Voltage Range:110-457 VAC
Related Articles
How to Wire a Battery Bank for Your UPS System
Learn how to wire UPS battery banks correctly. Series vs parallel connections, cable sizing, fuse protection, and safety procedures for lead-acid and lithium.
Read: How to Wire a Battery Bank for Your UPS System →UPS Battery Not Holding Charge? Causes and Solutions
Diagnose why your UPS battery is not holding charge. Common causes include age, heat damage, sulfation, and faulty charger circuits. Fixes inside.
Read: UPS Battery Not Holding Charge? Causes and Solutions →UPS Backup Power Solutions for Iraqi Businesses
Reliable UPS solutions for Iraq's challenging power grid. Wide input range, generator compatibility, extended runtime, and dust-resistant designs.
Read: UPS Backup Power Solutions for Iraqi Businesses →