Voltronic Power Three-Phase Online UPS Fortress 3/3 100K / Fortress 3/3 120K / Fortress 3/3 180K / Fortress 3/3 200K / Fortress 3/3 240K / Fortress 3/3 300K / Fortress 3/3 60K / Fortress 3/3 80K
Discover the Fortress 3/3 100K by Voltronic Power with 3 x 380/400/415 VAC and auto-sensing 50/60Hz frequency for reliable power protection.
Models and prices
- Fortress 3/3 100KAED 95,000incl. VAT
- Fortress 3/3 120KAED 95,000incl. VAT
- Fortress 3/3 180KAED 95,000incl. VAT
- Fortress 3/3 200KAED 95,000incl. VAT
- Fortress 3/3 240KAED 95,000incl. VAT
- Fortress 3/3 300KAED 95,000incl. VAT
Show all 8 models
- Fortress 3/3 60KAED 95,000incl. VAT
- Fortress 3/3 80KAED 95,000incl. VAT
Technical Specifications
| Parameter | Fortress 3/3 100K | Fortress 3/3 120K | Fortress 3/3 180K | Fortress 3/3 200K | Fortress 3/3 240K | Fortress 3/3 300K | Fortress 3/3 60K | Fortress 3/3 80K |
|---|---|---|---|---|---|---|---|---|
| Output | ||||||||
| Nominal Voltage | 3 x 380/400/415 VAC (3Ph+N) | |||||||
| Voltage Regulation (Steady state) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 2% Typical (unbalanced load) | ≤ ± 1% Typical (balanced load) | ≤ ± 2% Typical (unbalanced load) |
| Frequency Range (Synchronized range) | 46Hz ~ 54Hz or 56Hz ~ 64Hz | |||||||
| Overload Capability | ≤ 110% for 1 hour, 111% ~ 125% for 10 mins, 126%~150% for 1 min and >150% for 200ms | |||||||
| Harmonic Distortion | ≤ 2% THD (Linear Load); ≤ 4% THD (Non-linear Load) | |||||||
| Input | ||||||||
| Voltage Range | 110-300 VAC @ 50% load; 184-276 VAC @100% load | |||||||
| Nominal Frequency | 50/60Hz (Auto sensing) | |||||||
| Frequency Range | 40Hz ~ 70Hz | |||||||
| Power Factor | >= 0.99 @ 100% load | |||||||
| Harmonic Distortion (THDi) | <5% @ 100% load | |||||||
| Efficiency | ||||||||
| AC Mode | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% | 95.5% | 95% | 96% |
| ECO Mode | 98.5% | 98.5% | 98.5% | 98.5% | 98.5% | 98.5% | 98% | 99% |
| Battery Mode | 94.5% | 94.5% | 94.5% | 94.5% | 94.5% | 94.5% | 94% | 95.5% |
| Battery Charging | ||||||||
| Maximum Voltage | +/- 240V (12V x 40 Pcs) | |||||||
| Minimum Voltage | +/- 192V (12V x 32 Pcs) | |||||||
| Floating Charge Voltage | 2.28V / Cell (2.25 ~ 2.33 Selectable) | |||||||
| Boost Charging Voltage | 2.35V/Cell | |||||||
| Maximum Charging Current | 24A (Adjustable) | 36A (Adjustable) | 54A (Adjustable) | 54A (Adjustable) | 72A (Adjustable) | 90A (Adjustable) | 18A (Adjustable) | 18A (Adjustable) |
| Temperature Compensation | Yes | |||||||
| Communication | ||||||||
| Management | Supports Windows® Family, Linux and MAC | |||||||
| Optional SNMP | Power management from SNMP manager and web browser | |||||||
| Certifications | ||||||||
| Safety | IEC/EN 62040-1 | |||||||
| EMC | IEC/EN 62040-2 Category C3 | |||||||
| Physical | ||||||||
| IP Class | IP20, optional IP31 | |||||||
| Dimension, D x W x H (mm) | 1000x430x1200 | 1000x430x1200 | 1000x600x1200 | 1000x600x1200 | 1100x600x1475 | 1100x600x1475 | 1000x320x800 | 1000x430x1200 |
| Net Weight (Kgs) | 169 | 169 | 249 | 249 | 360 | 396 | 94 | 125 |
| Mechanical Data | ||||||||
| Weight | 169 | 169 | 249 | 249 | 360 | 396 | 94 | 125 |
| Operating Conditions | ||||||||
| Operating Temperature | 0-40°C | |||||||
| Operating Humidity | < 95% and non-condensing | |||||||
| Altitude | <1000m for Nominal power | |||||||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Backfeed detection built-in
- Single power module on/off control: Single power module on/off control through LCD panel
- Pluggable power module design with: Pluggable power module design with front access
- Parallel operation up to 4: Parallel operation up to 4 units with common battery
- Dual-mains inputs
- Built-in 4 switches including Mains: Built-in 4 switches including Mains input, bypass input, output and maintenance bypass switch
- Flexible battery configuration and adjustable: Flexible battery configuration and adjustable charging current
- Optional extra communication is available
- Emergency power off function (EPO)
- Generator compatible
- 50Hz/60Hz frequency converter mode
- Compatible to Lithium-ion battery
Frequently Asked Questions
What voltage does the Voltronic UPS Fortress 3/3 100K operate on?
The Voltronic UPS Fortress 3/3 100K has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) and an operating voltage range of 110-300 VAC @ 50% load.
What are the physical dimensions and weight of the Voltronic UPS Fortress 3/3 100K?
The Voltronic UPS Fortress 3/3 100K measures 1000x430x1200 and weighs 169.
What is the operating temperature range of the Voltronic UPS Fortress 3/3 100K?
The Voltronic UPS Fortress 3/3 100K operates across 0-40°C and a humidity range of < 95% and non-condensing.
What is the maximum charge current of the Voltronic UPS Fortress 3/3 100K?
The Voltronic UPS Fortress 3/3 100K has a maximum charge current of 24A (Adjustable).
How does the Voltronic UPS Fortress 3/3 100K regulate voltage?
The Voltronic UPS Fortress 3/3 100K provides a voltage regulation of ≤ ± 2% Typical (unbalanced load).
What ingress protection rating does the Voltronic UPS Fortress 3/3 100K carry?
The Voltronic UPS Fortress 3/3 100K carries an ingress protection rating of IP20, optional IP31.
What is the power quality of the Voltronic UPS Fortress 3/3 100K?
The Voltronic UPS Fortress 3/3 100K has a power factor of >= 0.99 @ 100% load and a harmonic distortion of <5% @ 100% load.
What certifications does the Voltronic UPS Fortress 3/3 100K have?
The Voltronic UPS Fortress 3/3 100K is certified to IEC/EN 62040-1 and IEC/EN 62040-2 Category C3, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Fortress 3/3 100K?
The Voltronic UPS Fortress 3/3 100K is backed by a 2-year manufacturer warranty from Voltronic Power.
What voltage does the Voltronic UPS Fortress 3/3 120K operate on?
The Voltronic UPS Fortress 3/3 120K has a nominal voltage of 3 x 380/400/415 VAC (3Ph+N) and an operating voltage range of 110-300 VAC @ 50% load.