Voltronic Axpert VM IV 4K6K TWIN 4KW Solar Inverter
- Max. PV Current:27A
- Max. PV Array Open Circuit Voltage:500Vdc

The ESS510 5.5KW is a solar inverter rated 5.5KW. Every figure on this page is read from the manufacturer's manual for the ESS510 series.
In stock
The ESS510 5.5KW is a solar inverter rated 5.5KW. Every figure on this page is read from the manufacturer's manual for the ESS510 series.
Specifications last updated 17 August 2026
| Max. Output Current | 23.9A* |
|---|---|
| Efficiency (DC to AC) | 208/220/230/240 VAC |
| Capacity | 4800Wh 48VDC 52.5V |
| Max Continuous Discharging Current | 120A |
| Protection | BMS, Breaker |
| Charge Current | 30A |
| Inner Resistance | <20m ohm |
| Number of MPP Trackers / Maximum Input Current | 2 / 2 x 13 A |
| Maximum PV Input Power | 6500W |
| Nominal DC Voltage / Maximum DC Voltage | 360 VDC / 500 VDC |
| Start-up Voltage / Initial Feeding Voltage | 116 VDC / 150 VDC |
| Output Voltage Range | 184 - 264.5 VAC* |
| Maximum Conversion Efficiency (DC/AC) | 96% |
| European Efficiency @ Vnominal | 95% |
| Acceptable Input Voltage Range | 170 -280 VAC |
| Maximum AC Input Current | 40 A |
| Maximum Charging Current | 100 A |
| Nominal Voltage | 51.2VDC |
| Full Charge Voltage (FC) | 56V |
| Full Discharge Voltage (FD) | 42V |
| Max Discharging Current | 192A at 1min |
| Maximum Charge Current | 50A (0.5C) |
| Compliance Safety | IEC/EN 62109-1/-2, IEC 62040-1, EN 61000-6-4, EN IEC 61000-6-2, EN IEC 61000-3-11, EN 61000-3-12, IEC 61727, IEC 62116, G99, NRS 097-2-1, EN 50549-1 |
| Battery Module Compliance Safety | IEC 62619, EN 61000-6-3, EN 61000-6-1, UKCA, UN38.3 |
Looking up an error code on this Voltronic Power ESS510? Browse the full list of codes for this device, with the cause and recommended fix for each.
View error codes for this device →







Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The ESS510 5.5KW takes up to 6500W of PV array.
The ESS510 5.5KW works with a 51.2VDC bank. It charges at up to 50A (0.5C), and that current — not the bank's capacity — is what the cabling and the fuse between bank and unit have to be sized for.
Peak efficiency is 96%. Whatever is not converted leaves as heat, so the ESS510 5.5KW needs clear air around it and a mounting spot that is not the hottest wall in the building.