- Rated Power: 8000VA/8000W
- AC Voltage Regulation (Batt. Mode): 230VAC ± 5%
- Surge Power: 16000VA
- Efficiency (Peak): 93%
In stock
Voltronic Axpert MAX II TWIN 8K features
About the Voltronic Axpert MAX II TWIN 8K
The Voltronic Power Axpert MAX II TWIN inverter is engineered for high performance with a rated power of 8000VA/8000W. It ensures stable energy output with 230VAC ± 5% regulation in battery mode, making it a reliable choice for various applications. Ideal for residential and commercial use, the Axpert MAX II TWIN is perfect for backup power systems, solar energy setups, and off-grid applications.
Specifications last updated 23 July 2026
Voltronic Axpert MAX II TWIN 8K full specifications
Electrical
| Circulation Current under No Load Condition | Max 2A |
|---|---|
| DC Offset | ≤100mV |
| High DC Cut-off Voltage | 66Vdc |
| High DC Recovery Voltage | 64Vdc |
| Low DC Cut-off Voltage | 44Vdc |
| Max. Charging Current | 120A |
| Max. Input Current | 27A x 2 (MAX 40A) |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Nominal DC Input Voltage | 48Vdc |
| PV Array MPPT Voltage Range | 90Vdc 450Vdc |
| Parallel Kit | YES |
| Parallel communication | CAN |
| Peak Efficiency | 93% |
| Rated Output Power | 8000W |
| Start-up Voltage | 80V +/- 5Vdc |
| Transfer time in parallel mode | Max 50ms |
| Max parallel numbers | 6 |
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| High Loss Return Voltage | 270Vac±7V |
| High Loss Voltage | 280Vac±7V |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
| Max 2nd Output Current | 40A |
| Max AC Input Current | 60A |
| Max AC Input Voltage | 300Vac |
| Max Output Current for 2nd output | 40A |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Nominal Input Voltage | 230Vac |
| Output Short Circuit Protection | Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits |
| Battery | 56.4Vdc |
| Cold Start Voltage | 46.0Vdc |
| DC Voltage | DC Offset ≦100mV Power Limitation 50Vdc |
| Efficiency | >95% ( Rated R load Line Mode |
| Floating Charging Voltage | 54Vdc |
| Input Voltage Waveform | Sinusoidal (utility or generator) Nominal |
| Output | Charge Time to |
| Output Frequency | 60Hz or 50Hz Peak |
| Output Power | For 8KW model, when |
| Output Voltage Regulation | 230Vac± 5% |
| Overcharge Protection | 66Vdc Charging Algorithm 3-Step Charging Curve Time |
| Overload Protection | Surge |
| Rated Power | 8000W Max. PV Array Open Circuit |
| Safety Certification | CE |
| Transfer Time | 10ms typical (UPS); |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
| Surge Power | 16000VA |
| Efficiency (Peak) | 93% |
| Waveform | Pure sine wave |
| Battery Voltage | 48 VDC |
| Floating Charge Voltage | 54 VDC |
| Solar Charger Type | MPPT |
| Maximum PV Array Power | 11000W (5500W x 2) |
| MPPT Range @ Operating Voltage | 90 – 450 VDC |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Maximum PV Input Current | 27A x 2 (MAX 40A) |
| Maximum Solar Charge Current | 150A |
| Maximum AC Charge Current | 120A |
| Maximum Charge Current | 150A |
| Compliance Safety | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
Mechanical
| Dimension, D x W x H (mm) | 158.4 x 503.6 x 530.8 |
|---|---|
| Net Weight (kgs) | 20 |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
Environmental
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature Range | -10°C to 50°C |
| Storage temperature | -15°C~ 60°C |
| Operating Temperature | -10°C to 50°C |
Certifications
- IEC 62109
- IEC 61683
- EN/IEC 61000-6-2
- 61000-6-4
- 61000-3-11
- 61000-3-12
Related Products

Axpert MAX II TWIN 11K
- Rated Power:11000VA/11000W
- AC Voltage Regulation (Batt. Mode):230VAC ± 5%

Axpert MAX II TWIN 12K
- Rated Power:12000VA/12000W
- AC Voltage Regulation (Batt. Mode):230VAC ± 5%

Voltronic Axpert MAX II TWIN 11K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

Voltronic Axpert MAX II TWIN 12K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

Voltronic Axpert MAX II TWIN 8K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

Axpert MAX II Duplex 8K
- Rated Power:8000VA/8000W
- AC Voltage Regulation (Batt. Mode):230VAC ± 5%

Axpert King II TWIN
- RATED POWER:6000-6200 W
- PARALLEL CAPABILITY:Up to 9 units

Axpert VM 4 TWIN 6K
- RATED POWER:6000VA/6000W
- AC Voltage Regulation (Batt. Mode):230VAC ± 10%
Related Articles
Voltronic Axpert vs Growatt SPF: Off-Grid Inverter Comparison
Compare the Voltronic Axpert and Growatt SPF off-grid inverters. Power ratings, MPPT, parallel operation, battery support, and field reliability.
Read: Voltronic Axpert vs Growatt SPF: Off-Grid Inverter Comparison →Inverter Overload Protection: How It Works and How to Prevent It
Understand how inverter overload protection works. Learn causes of overload, warning signs, load management strategies, and how to size your inverter.
Read: Inverter Overload Protection: How It Works and How to Prevent It →Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options
Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →