Voltronic Axpert MAX II TWIN 11K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

The Axpert MAX II TWIN 12K is an off-grid solar inverter rated Axpert MAX II TWIN 12K.
In stock
The Axpert MAX II TWIN 12K is an off-grid solar inverter rated Axpert MAX II TWIN 12K. Every figure on this page is read from the manufacturer's manual for the Axpert MAX II TWIN series.
Specifications last updated 18 August 2026
| Parallel Capability | YES, 6 units |
|---|---|
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% |
| Efficiency (Peak) | 93% |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Compliance Safety | IEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12 |
| Rated Power | 12000VA/12000W |
| Surge Power | 24000VA |
| Maximum PV Array Power | 18000W (Max. 12000W per tracker) |
| Maxmum Solar Charge Current | 200A |
| Maximum AC Charge Current | 200A |
| Maximum Charge Current | 200A |
| High Loss Frequency | 65±1Hz |
| High Loss Return Frequency | 63±1Hz |
| High Loss Return Voltage | 270Vac±7V |
| High Loss Voltage | 280Vac±7V |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) |
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) |
| Max AC Input Voltage | 300Vac |
| Max. PV Array Open Circuit Voltage | 500Vdc |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) |
| Output Short Circuit Protection | Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits |
| PV Array MPPT Voltage Range | 90Vdc 450Vdc |
| Start-up Voltage | 80V +/- 5Vdc |
| Low DC Cut-off Voltage | 44Vdc |
| Nominal DC Input Voltage | 48Vdc |
| Charging Current | 150A UPS |
| Cold Start Voltage | 46.0Vdc |
| Floating Charging Voltage | 54Vdc |
| Input Voltage Waveform | Sinusoidal (utility or generator) Nominal |
| Output | Charge Time to |
| Overload Protection | Surge |
| Safety Certification | CE |
| Waveform | Pure sine wave |
| Solar Charger Type | MPPT |
| Parallel Kit | YES |
| Parallel communication | CAN |
| Output Power | For 8KW model, when |
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |








Compare the Voltronic Axpert and Growatt SPF off-grid inverters. Power ratings, MPPT, parallel operation, battery support, and field reliability.
Read: Voltronic Axpert vs Growatt SPF: Off-Grid Inverter Comparison →Understand how inverter overload protection works. Learn causes of overload, warning signs, load management strategies, and how to size your inverter.
Read: Inverter Overload Protection: How It Works and How to Prevent It →Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →The Axpert MAX II TWIN 12K is rated 12000VA/12000W continuous, with 24000VA available on surge for the second a motor or a compressor starts. Size the load you actually intend to run against the continuous figure, never against the surge one.
Peak efficiency is 93%. Whatever is not converted leaves as heat, so the Axpert MAX II TWIN 12K needs clear air around it and a mounting spot that is not the hottest wall in the building.
Yes — up to 6 units. That is the published ceiling for this model, so a larger installation is built from a bigger unit rather than a longer stack.