Voltronic Power Inverters AXPERT-MAX-II-TWIN-11/VOLTRONIC-AXPERT-MAX-II-TWIN-12/VOLTRONIC-AXPERT-MAX-II-TWIN-8/AXPERT-MAX-II-TWIN-8K

The Axpert MAX II TWIN 11K is an off-grid solar inverter rated 11000VA/11000W.

Models Covered: AXPERT-MAX-II-TWIN-11K, AXPERT-MAX-II-TWIN-12K, VOLTRONIC-AXPERT-MAX-II-TWIN-11K, VOLTRONIC-AXPERT-MAX-II-TWIN-12K, VOLTRONIC-AXPERT-MAX-II-TWIN-8K, AXPERT-MAX-II-TWIN-8K

Manufacturer: Voltronic Power

Application: The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K is an Inverter with a rated power of 11000 VA/11000W, making it a dependable choice for off-grid, hybrid and backup power installations. It accepts an operating voltage range of 170-280 VAC in UPS mode (For Personal Computers). It operates at an efficiency of 93%. Its output waveform is Sinusoidal (utility or generator) Nominal. It is rated to operate across -10°C to 50°C, with a humidity tolerance of 5% to 95%. Monitoring and control are available over USB/RS232/RS485/WiFi/Dry-contact. The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K is certified to IEC 62109, IEC 61683, EN, IEC 61000-6-2, 61000-6-4, 61000-3-11 and 61000-3-12 and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Maximum AC Charge Current of 150A, Maximum Charge Current of 150A and High Loss Frequency of 65±1Hz.

Models and prices

Technical Specifications

Technical Specifications
ParameterAXPERT-MAX-II-TWIN-11KAXPERT-MAX-II-TWIN-12KVOLTRONIC-AXPERT-MAX-II-TWIN-11KVOLTRONIC-AXPERT-MAX-II-TWIN-12KVOLTRONIC-AXPERT-MAX-II-TWIN-8KAXPERT-MAX-II-TWIN-8K
Additional Specifications
Parallel CapabilityYES, 6 units
Selectable Voltage Range170-280 VAC (For Personal Computers)
AC Voltage Regulation (Batt. Mode)230VAC ± 5%
Efficiency (Peak)93%
Maxmum Solar Charge Current150A200A———150A
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
High Loss Return Voltage270Vac±7V
High Loss Voltage280Vac±7V
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
Low Loss Voltage170Vac±7V (UPS) 90Vac±7V (Appliances)
Max AC Input Voltage300Vac
Max. PV Array Open Circuit Voltage500Vdc
Nominal Input Frequency50Hz/60Hz (Auto detection)
Output Short Circuit ProtectionLine mode: Circuit Breaker (70A) Battery mode: Electronic Circuits
PV Array MPPT Voltage Range90Vdc 450Vdc
Start-up Voltage80V +/- 5Vdc
Low DC Cut-off Voltage44Vdc
Nominal DC Input Voltage48Vdc
Cold Start Voltage46.0Vdc
Floating Charging Voltage54Vdc
Input Voltage WaveformSinusoidal (utility or generator) Nominal
OutputCharge Time to
Overload ProtectionSurge
Safety CertificationCE
Parallel KitYES
Parallel communicationCAN
Operating Temperature-10°C to 50°C
Charging Current150A UPS
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Max AC Input Current60A
Nominal Input Voltage230Vac
Max parallel numbers6
DC Offset≤100mV
Peak Efficiency93%
Efficiency>95% ( Rated R load Line Mode
Output Frequency60Hz or 50Hz Peak
Output Voltage Regulation230Vac± 5%
Operating Temperature Range-10°C to 50°C
Circulation Current under No Load ConditionMax 2A
Transfer time in parallel modeMax 50ms
Max 2nd Output Current40A
Max Output Current for 2nd output40A
Physical
Communication InterfaceUSB/RS232/RS485/WiFi/Dry-contact
Dimension, D x W x H (mm)158.4 x 503.6 x 530.8
Net Weight (kgs)20
Certifications
Compliance SafetyIEC 62109, IEC 61683, EN/IEC 61000-6-2, 61000-6-4, 61000-3-11, 61000-3-12
AC Output
Rated Power11000VA/11000W12000VA/12000W11000W Max. PV Array Open Circuit12000VA/12000W8000W Max. PV Array Open Circuit8000VA/8000W
Surge Power22000VA24000VA22000VA24000VA16000VA16000VA
WaveformPure sine wave
Transfer Time——10ms typical (UPS);10 ms (For Personal Computers) ; 20 ms (For Home Appliances)10ms typical (UPS);—
Solar Charger & AC Charger
Maximum PV Array Power13000W (6500W x 2)18000W (Max. 12000W per tracker)13000W (6500W x 2)18000W (Max. 12000W per tracker)11000W (5500W x 2)11000W (5500W x 2)
Maximum AC Charge Current150A200A150A200A120A120A
Maximum Charge Current150A200A150A200A150A150A
Solar Charger TypeMPPT
MPPT Range @ Operating Voltage90 – 450 VDC
Maximum PV Array Open Circuit Voltage500 VDC
Maximum PV Input Current——40A/27A (MAX 60A)40A/27A (MAX 60A)27A x 2 (MAX 40A)—
Maximum Solar Charge Current——150A200A150A—
Operating Conditions
Humidity5% to 95%5% to 95%5% to 95%5% to 95% Relative Humidity (Non-condensing)5% to 95%5% to 95%
Storage Temperature-15°C to 60°C-15°C to 60°C-15°C~ 60°C-15°C to 60°C-15°C~ 60°C-15°C to 60°C
Electrical / AC Output Data
Max. Charging Current——150A—120A—
Max. Input Current——27A x 2(MAX 40A)—27A x 2 (MAX 40A)—
High DC Cut-off Voltage——63Vdc—66Vdc—
High DC Recovery Voltage——61Vdc—64Vdc—
DC Voltage——DC Offset ≦100mV Power Limitation 55Vdc—DC Offset ≦100mV Power Limitation 50Vdc—
Rated Output Power——11000W—8000W—
Electrical Data
Battery——Real-time Activate Battery It’s real-time action to activate battery equalization.—56.4Vdc—
Battery
Overcharge Protection——63Vdc Charging Algorithm 3-Step Charging Curve Time63 VDC66Vdc Charging Algorithm 3-Step Charging Curve Time66 VDC
Battery Voltage48 VDC
Floating Charge Voltage54 VDC

Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.

Availability & grid compliance in the UAE

MarketUAE
Grid authority / regulatorDEWA, ADDC, SEWA
Quotation currencyAED
Support hours timezoneAsia/Dubai
Main citiesDubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah

Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.

For prices, see Voltronic Inverters: Prices in UAE. Store pickup — collect your order from our store in Dubai or Riyadh.

Key Features & Technical Highlights

  • Increased PV power
  • Touchable button with 5" color: Touchable button with 5" color LCD
  • Status indication with RGB lights
  • Dual outputs for smart load: Dual outputs for smart load management
  • Built-in WiFi with APP for: Built-in WiFi with APP for mobile monitoring and OTA firmware upgrade
  • Supports USB On-the-Go function
  • Built-in BMS communication port
  • Built-in meter calibration for optimized: Built-in meter calibration for optimized system operation
  • Battery independent design
  • Built-in anti-dust kit
  • Built-in DC output for DC: Built-in DC output for DC fan, LED bulb, router and so on
  • Parallel operation with 6 units

Frequently Asked Questions

What is the rated power of the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K has a rated power of 11000 VA/11000W and a surge capability of 22000 VA.

What voltage range does the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K accept?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K accepts an input voltage range of 170-280 VAC in UPS mode (For Personal Computers).

What is the operating temperature range of the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K operates across -10°C to 50°C and a humidity range of 5% to 95%.

What is the efficiency of the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K has an efficiency of 93%.

What solar input can the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K handle?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K supports a maximum PV array power of 13000W (6500W x 2), a maximum solar charge current of 150A and a maximum PV array open-circuit voltage of 500 VDC.

What output waveform does the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K produce?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K produces a Sinusoidal (utility or generator) Nominal output waveform.

How does the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K regulate voltage?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K provides a voltage regulation of 230 VAC ± 5%.

What communication options does the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K offer?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K offers USB/RS232/RS485/WiFi/Dry-contact connectivity for monitoring and control.

Can multiple Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K units run in parallel?

Yes — the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K supports parallel operation (YES, 6 units).

What certifications does the Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K have?

The Voltronic 11 kW Hybrid Solar Inverter Axpert MAX II TWIN 11K is certified to IEC 62109, IEC 61683, EN, IEC 61000-6-2, 61000-6-4, 61000-3-11 and 61000-3-12, meeting recognised international standards for safety and performance.