Voltronic Axpert MAX II Duplex 8K Off-Grid Solar Inverter
- Parallel Capability:YES, 6 units
- Selectable Voltage Range:170-280 VAC (For Personal Computers)

The Axpert MAX II Duplex 11K is an off-grid solar inverter rated Axpert MAX II Duplex 11K.
In stock
The Axpert MAX II Duplex 11K is an off-grid solar inverter rated Axpert MAX II Duplex 11K. Every figure on this page is read from the manufacturer's manual for the Axpert MAX II Duplex series.
Specifications last updated 18 August 2026
| Parallel Capability | YES, 6 units |
|---|---|
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ±5% |
| Efficiency (Peak) | 93% |
| MPPT Range @ Operating Voltage | 90-450 VDC |
| Maximum PV Input Current | 27A x 2 (MAX 40A) |
| Maxmum Solar Charge Current | 150A |
| Maximum Charge Current | 150A |
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact |
| Rated Power | 11000VA/11000W |
| Surge Power | 22000VA |
| Maximum PV Array Power | 11000W (5500W x 2) |
| Maximum AC Charge Current | 150A |
| Transfer Time | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
| DC Voltage | 12 VDC ±5%, 100W |
| Floating Charge Voltage | 54 VDC |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Waveform | Pure sine wave |
| Compliance Safety | CE |
| Battery Voltage | 48 VDC |
| Overcharge Protection | 63 VDC |
| High Loss Frequency | 65±1Hz |
| High Loss Return Voltage | 270Vac±7V |
| High Loss Voltage | 280Vac±7V |
| Low Loss Frequency | 40±1Hz |
| Low Loss Return Frequency | 42±1Hz |
| Max AC Input Voltage | 300Vac |
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | 50Hz/60Hz ( |
| Output Short Circuit Protection | Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits |
| Parallel Kit | YES |
| Parallel communication | CAN |
| Start-up Voltage | 80V +/- 5Vdc |
| High DC Recovery Voltage | 61Vdc | 64Vdc |
| Low DC Cut-off Voltage | 44Vdc |
| Cold Start Voltage | 46.0Vdc |
| Input Voltage Waveform | Sinusoidal (utility or generator) Nominal |
| Overload Protection | Surge |
| Output Power | For 8KW model, when |
| Dimension, D x W x H (mm) | 147.4x 432.5 x 553.6 |
|---|---|
| Net Weight (kgs) | 18.4 |
| Humidity | 5% to 95% |
|---|---|
| Operating Temperature | -10°C to 50°C |
| Storage Temperature | -15°C to 60°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert MAX II Duplex 11K is rated 11000VA/11000W continuous, with 22000VA available on surge for the second a motor or a compressor starts. Size the load you actually intend to run against the continuous figure, never against the surge one.
The Axpert MAX II Duplex 11K takes up to 11000W (5500W x 2) of PV array. The string has to stay below 500 VDC open-circuit — that ceiling is reached on a cold bright morning, not at noon. The tracker works over 90-450 VDC, so wire the modules to land inside that window.
The Axpert MAX II Duplex 11K works with a 48 VDC bank. It charges at up to 150A, and that current — not the bank's capacity — is what the cabling and the fuse between bank and unit have to be sized for.