Voltronic Power Inverters AXPERT-MAX-II-DUPLEX-11/AXPERT-MAX-II-DUPLEX-11/VOLTRONIC-AXPERT-MAX-II-DUPLEX-8/AXPERT-MAX-II-DUPLEX-8K
Discover the Axpert MAX II Duplex 11K inverter by Voltronic Power with 11000VA/11000W rated power and 230VAC regulation for efficient energy solutions.
Models and prices
- VOLTRONIC-AXPERT-MAX-II-DUPLEX-11KAED 3,200incl. VAT
- AXPERT-MAX-II-DUPLEX-11KAED 3,420incl. VAT
- VOLTRONIC-AXPERT-MAX-II-DUPLEX-8KAED 3,200incl. VAT
- AXPERT-MAX-II-DUPLEX-8KAED 4,645incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-AXPERT-MAX-II-DUPLEX-11K | AXPERT-MAX-II-DUPLEX-11K | VOLTRONIC-AXPERT-MAX-II-DUPLEX-8K | AXPERT-MAX-II-DUPLEX-8K |
|---|---|---|---|---|
| Electrical Data | ||||
| Circulation Current under No Load Condition | Max 2A | |||
| Efficiency (Line Mode) | >95% (Rated R load, battery full charged) | — | >95% (Rated R load, | — |
| High Loss Return Frequency | 63±1Hz | |||
| Low Loss Return Voltage | 180Vac±7V (UPS); 100Vac±7V (Appliances) | |||
| Low Loss Voltage | 170Vac±7V (UPS) 90Vac±7V (Appliances) | |||
| Max AC Input Current | 60A | |||
| Max. Input Current | 27A x 2(MAX 40A) | |||
| Max. PV Array Open Circuit Voltage | 500Vdc | |||
| Nominal Input Voltage | 230Vac | |||
| PV Array MPPT Voltage Range | 90Vdc~450Vdc | — | 90Vdc 450Vdc | — |
| Transfer time in parallel mode | Max 50ms | |||
| Max parallel numbers | 6 | |||
| DC Offset | ≤100mV | |||
| High DC Cut-off Voltage | 63Vdc | — | 66Vdc | — |
| Nominal DC Input Voltage | 48Vdc | |||
| Peak Efficiency | 93% | |||
| Battery | 56.4Vdc | |||
| Charging Current | 150A UPS | |||
| Efficiency | >95% ( Rated R load Line Mode | |||
| Floating Charging Voltage | 54Vdc | |||
| Output Voltage Regulation | 230Vac± 5% | |||
| Overcharge Protection | 63Vdc Charging Algorithm 3-Step Charging Curve Time | 63 VDC | 66Vdc Charging Algorithm 3-Step Charging Curve Time | 66 VDC |
| Rated Output Power | 11000W | — | 8000W | — |
| Rated Power | 11000W Max. PV Array Open Circuit | 11000VA/11000W | 8000W Max. PV Array Open Circuit | 8000VA/8000W |
| Safety Certification | CE | |||
| Surge Power | 22000VA | 22000VA | 16000VA | 16000VA |
| Maximum PV Array Power | 11000W (5500W x 2) | 11000W (5500W x 2) | 8000W (4000W x 2) | 8000W (4000W x 2) |
| Maximum AC Charge Current | 150A | 150A | 120A | 120A |
| Overcharge | Protection 66Vdc | |||
| Additional Specifications | ||||
| High Loss Frequency | 65±1Hz | |||
| High Loss Return Voltage | 270Vac±7V | |||
| High Loss Voltage | 280Vac±7V | |||
| Low Loss Frequency | 40±1Hz | |||
| Low Loss Return Frequency | 42±1Hz | |||
| Max AC Input Voltage | 300Vac | |||
| Max. Charging Current | 150A | |||
| Nominal Input Frequency | 50Hz/60Hz (Auto detection) | 50Hz/60Hz (Auto detection) | 50Hz/60Hz ( | 50Hz/60Hz ( | 50Hz/60Hz (Auto detection) | 50Hz/60Hz ( |
| Output Short Circuit Protection | Line mode: Circuit Breaker (70A) Battery mode: Electronic Circuits | |||
| Parallel Kit | YES | |||
| Parallel communication | CAN | |||
| Start-up Voltage | 80V +/- 5Vdc | |||
| High DC Recovery Voltage | 61Vdc | 61Vdc | 64Vdc | 64Vdc | 61Vdc | 64Vdc |
| Low DC Cut-off Voltage | 44Vdc | |||
| Cold Start Voltage | 46.0Vdc | |||
| Input Voltage Waveform | Sinusoidal (utility or generator) Nominal | |||
| Output Frequency | 60Hz or 50Hz Peak | |||
| Overload Protection | Surge | |||
| Selectable Voltage Range | 170-280 VAC (For Personal Computers) | |||
| Parallel Capability | YES, 6 units | |||
| Maxmum Solar Charge Current | 150A | |||
| AC Output | ||||
| DC Voltage | DC Offset ≦100mV Power Limitation 50Vdc | 12 VDC ±5%, 100W | DC Offset ≦100mV Power Limitation 50Vdc | 12 VDC ±5%, 100W |
| Transfer Time | 10ms typical (UPS); | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) | 10ms typical (UPS); | 10 ms (For Personal Computers) ; 20 ms (For Home Appliances) |
| AC Voltage Regulation (Batt. Mode) | 230VAC ± 5% | 230VAC ±5% | 230VAC ± 5% | 230VAC ±5% |
| Efficiency (Peak) | 93% | |||
| Waveform | Pure sine wave | |||
| Battery | ||||
| Battery Voltage | 48 VDC | |||
| Floating Charge Voltage | 54 VDC | |||
| Solar Charger & AC Charger | ||||
| MPPT Range @ Operating Voltage | 90 – 450 VDC | 90-450 VDC | 90 – 450 VDC | 90-450 VDC |
| Maximum PV Array Open Circuit Voltage | 500 VDC | |||
| Maximum PV Input Current | 27A x 2 (MAX 40A) | |||
| Maximum Solar Charge Current | 150A | |||
| Maximum Charge Current | 150A | |||
| Standard | ||||
| Compliance Safety | CE | |||
| Physical | ||||
| Dimension, D x W x H (mm) | 147.4 x 432.5 x 553.6 | 147.4x 432.5 x 553.6 | 147.4 x 432.5 x 553.6 | 147.4x 432.5 x 553.6 |
| Net Weight (kgs) | 18.4 | |||
| Communication Interface | USB/RS232/RS485/WiFi/Dry-contact | |||
| Operating Environment | ||||
| Humidity | 5% to 95% | |||
| Storage Temperature | -15°C~ 60°C | -15°C to 60°C | -15°C~ 60°C | -15°C to 60°C |
| Operating Temperature | -10°C to 50°C | |||
| Operating Conditions | ||||
| Operating Temperature Range | -10°C to 50°C | |||
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Two independent AC power sources: Two independent AC power sources connected and switched automatically
- Status indication with RGB lights
- Maximum PV input current 27A
- Adjustable charging current for two: Adjustable charging current for two different power sources via LCD operation and mobile APP
- Built-in Wi-Fi for mobile monitoring: Built-in Wi-Fi for mobile monitoring (Android/iOS App is available)
- Supports USB On-the-Go function
- Replaceable fan design for ease: Replaceable fan design for ease of maintenance
- Battery independent design
- Configurable AC/PV output usage timer: Configurable AC/PV output usage timer and prioritization
- Built-in anti-dust kit
- Built-in DC output for DC: Built-in DC output for DC fan, LED bulb, router and so on
- Parallel operation with 6 units
Frequently Asked Questions
What is the rated power of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K has a rated power of 11000W and a surge capability of 22000 VA.
What voltage does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K operate on?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K has a nominal voltage of 48 VDC and an operating voltage range of 90 VDC~450 VDC.
What are the physical dimensions and weight of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K measures 147.4 x 432.5 x 553.6 and weighs 18.4.
What is the operating temperature range of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K operates across -10°C to 50°C and a humidity range of 5% to 95%.
What is the efficiency of the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K has an efficiency of >95% (Rated R load, battery full charged).
What solar input can the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K handle?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K supports a maximum PV array power of 11000W (5500W x 2), a maximum solar charge current of 150A and a maximum PV array open-circuit voltage of 500 VDC.
What transfer time and output waveform does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K provide?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K has a transfer time of Max 50ms and an output waveform of Sinusoidal (utility or generator) Nominal.
How does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K regulate voltage?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K provides a voltage regulation of 230 VAC± 5%.
What communication options does the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K offer?
The Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K offers USB/RS232/RS485/WiFi/Dry-contact connectivity for monitoring and control.
Can multiple Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K units run in parallel?
Yes — the Voltronic 11 kW Off-Grid Solar Inverter Axpert MAX II Duplex 11K supports parallel operation (YES).