Voltronic Power Winner Pro+

Voltronic Power UPS Datasheet — VOLTRONIC-WINNER-PRO-PLUS

Discover the Winner Pro+ Online UPS by Voltronic Power with a nominal voltage of 110-240VAC and precise voltage regulation of ±1%.

SKU: VOLTRONIC-WINNER-PRO-PLUS | Last Updated: 2026-03-27

⚡Electrical Specifications

Nominal Voltage110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 208/220/230/240VAC / 208/220/230/240VAC
Input Voltage Range60-145 VAC or 120-300 VAC (Based on load at 50%) / 60-145 VAC or 120-300 VAC (Based on load at 50%) / 60-145 VAC or 120-300 VAC (Based on load at 50%) / 110-300 VAC (Based on load at 50%) / 176-300 VAC (Based on load at 100%)
Frequency Range40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 40 Hz ~ 70 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz
Power Factor> 0.99 @ Nominal Voltage (100% load)
Output Voltage110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 110/115/120/127VAC or 208/220/230/240VAC / 208/220/230/240VAC / 208/220/230/240VAC
Voltage Regulation± 1%
Frequency Range (Synchronized Range)47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 47 ~ 53 Hz or 57 ~ 63 Hz / 46~54 Hz or 56~64 Hz / 46~54 Hz or 56~64 Hz
Frequency Range (Batt. Mode)50 Hz or 60Hz ± 0.5% / 50 Hz or 60Hz ± 0.5% / 50 Hz or 60Hz ± 0.5% / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz / 50 Hz ± 0.1 Hz or 60 Hz ± 0.1 Hz
Current Crest Ratio3:1
Harmonic Distortion≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) / ≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) / ≤ 3 % THD (Linear Load) ≤ 6 % THD (Non-linear Load) / ≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load) / ≤ 3 % THD (Linear Load) ≤ 5 % THD (Non-linear Load)
Transfer Time4 ms (Typical) / 4 ms (Typical) / 4 ms (Typical) / Zero / Zero
Waveform (Batt. Mode)Pure Sinewave
AC Mode88% / 89% / 90% / 92% / 93%
Battery Mode83% / 87% / 88% / 90% / 91%
Battery Type12 V / 9 Ah
Numbers2 / 3 / 4 / 6 / 8
Standard Model Typical Recharge Time4 hours recover to 90% capacity / 4 hours recover to 90% capacity / 4 hours recover to 90% capacity / 9 hours recover to 90% capacity / 9 hours recover to 90% capacity
Charging Current (max.)1 A / 1 A / 1 A / 1 A/2 A / 1 A/2 A
Charging Voltage27.4VDC ± 1% / 41.0VDC ± 1% / 54.7 VDC ± 1% / 82.1 VDC ± 1% 218.4 VDC ± 1% / 273VDC ± 1% 218.4 VDC ± 1% 273VDC ± 1%
Smart RS-232 / USBSupports Windows® 2000/2003/XP/Vista/2008, Windows® 7/8/10, Linux and MAC
Optional SNMPPower management from SNMP manager and web browser

🔧Mechanical Specifications

Dimension, D x W x H (mm)282 x 145 x 397 / 282 x 145 x 397 / 282 x 145 x 397 / 421 x 190 x 318 / 442 x 190 x 318
Net Weight (kgs)9.8 / 11.4 / 17 / 26.2 / 27.6
Weight9.8 / 11.4 / 17 / 26.2 / 27.6

🌡️Environmental Specifications

Humidity20-90 % RH @ 0-40°C (Non-condensing) / 20-90 % RH @ 0-40°C (Non-condensing) / 20-90 % RH @ 0-40°C (Non-condensing) / 0-95% RH @ 0-50°C (Non-condensing) / 0-95% RH @ 0-40°C (Non-condensing)
Noise LevelLess than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 50dB @ 1 Meter / Less than 55dB @ 1 Meter / Less than 58dB @ 1 Meter

📏Dimensions

Width145
Height397
Depth282
Weight9.8 / 11.4 / 17 / 26.2 / 27.6