Voltronic Power Atlas Line Interactive

UPSModel VOLTRONIC-ATLAS-LINE-INTERACTIVE

Voltronic UPS Atlas

Discover the Voltronic Power Atlas Line Interactive UPS with 110/120 or 220/230/240 VAC voltage, ensuring reliable power protection.

  • Voltage: 110-240 VAC
  • Voltage Range: 81-290 VAC
  • Frequency Range: 50/60 Hz ± 5Hz
AED 2,200incl. VAT

In stock

  • Delivered within 3 business days, door to door, to every market we serve.
  • Dispatched the same business day for an order placed before 21:00 (Dubai time), or the next business day after.
  • 2-year warranty

Voltronic UPS Atlas features

  • Excellent microprocessor control guarantees high

    Excellent microprocessor control guarantees high reliability

  • Boost and Buck AVR for

    Boost and Buck AVR for voltage stabilization

  • Auto restart while AC is

    Auto restart while AC is recovering

  • Pure sine wave

  • Off-mode charging

  • Cold-start function

  • Built-in USB communication port and

    Built-in USB communication port and RJ-45 phone protection

  • Provides battery backup and surge

    Provides battery backup and surge protected outputs

  • Easy replacement battery compartment

  • Hot-swappable battery design

  • Optional Coax Surge Protection for

    Optional Coax Surge Protection for TV antenna/network

  • Optional 5V USB charger port

    Optional 5V USB charger port for mobile devices

  • Site Wiring Fault for 120VAC

    Site Wiring Fault for 120VAC models

  • Battery Independent: turn ON and

    Battery Independent: turn ON and operate in the AC mode providing surge protection and AVR function without the batteries connected

  • Comply with energy Star 2.0

    Comply with energy Star 2.0 for 120VAC models

About the Voltronic UPS Atlas

The Voltronic UPS Atlas is a Line Interactive UPS with a voltage regulation of ±10%, making it a dependable choice for protecting critical loads from power interruptions. It accepts an operating voltage range of 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC. Its output waveform is Pure Sinewave. The unit measures 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 and weighs 7.4 / 7.9 / 8.5 / 11.8 / 13.1. The Voltronic UPS Atlas is certified to cTUVus, FCC, ENERGY STAR, CE, EN 62040-1 and IEC 62040-1 and is backed by a 2-year manufacturer warranty from Voltronic Power. Its published specifications also list Frequency Range (Batt. Mode) of 60 Hz or 50 Hz ±1 Hz, USB Charger ports of Type A x 2 and Load current of 2.1A(MAX).

Specifications last updated 27 March 2026

Voltronic UPS Atlas full specifications

Electrical(19)

Voltage110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC
Voltage Range81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC
Frequency Range50/60 Hz ± 5Hz(Auto sensing)
AC Voltage Regulation (Batt. Mode)±10%
Frequency Range (Batt. Mode)60 Hz or 50 Hz ±1 Hz
Transfer Time6ms typical, 10ms max
Waveform (Batt. Mode)Pure Sinewave
Battery Type & Number12 V/7 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 1 / 12 V/7 Ah x 2 / 12 V/9 Ah x 2
Typical Recharge Time4-6 hours recover to 90% capacity
USB Charger portsType A x 2
Output Voltage5 V±5%
Load current2.1A(MAX)
LCD DisplayInput/output voltage, input/output frequency, load in VA/Watts, battery capacity, estimated remaining runtime, site wiring fault indications.
Battery ModeSounding every 10 seconds
Low BatterySounding every second
OverloadSounding every 0.5 second
FaultContinuously sounding
Optional USB PortSupports Windows® Family, Linux and MAC
Compliance & Standards110/120VAC model: cTUVus (standard:UL 1778), FCC Part 15 Class B, ENERGY STAR (USA) / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013

Mechanical(3)

Dimension, D x W x H (mm)288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280
Net Weight (kgs)7.4 / 7.9 / 8.5 / 11.8 / 13.1
Weight7.4 / 7.9 / 8.5 / 11.8 / 13.1

Environmental(3)

Full ProtectionOverload, discharge, and overcharge protection
Humidity0-90 % RH @ 0- 40°C (Non-condensing)
Noise LevelLess than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB

Certifications(6)

  • cTUVus
  • FCC
  • ENERGY STAR
  • CE
  • EN 62040-1
  • IEC 62040-1

Downloads & support

Frequently Asked Questions

What voltage does the Voltronic UPS Atlas operate on?

The Voltronic UPS Atlas has a nominal voltage of 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC and an operating voltage range of 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC.

What are the physical dimensions and weight of the Voltronic UPS Atlas?

The Voltronic UPS Atlas measures 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 and weighs 7.4 / 7.9 / 8.5 / 11.8 / 13.1.

What transfer time and output waveform does the Voltronic UPS Atlas provide?

The Voltronic UPS Atlas has a transfer time of 6ms typical, 10ms max and an output waveform of Pure Sinewave.

How does the Voltronic UPS Atlas regulate voltage?

The Voltronic UPS Atlas provides a voltage regulation of ±10%.

How loud is the Voltronic UPS Atlas during operation?

The Voltronic UPS Atlas has a noise level of Less than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB during operation.

What certifications does the Voltronic UPS Atlas have?

The Voltronic UPS Atlas is certified to cTUVus, FCC, ENERGY STAR, CE, EN 62040-1 and IEC 62040-1, meeting recognised international standards for safety and performance.

What warranty coverage is available for the Voltronic UPS Atlas?

The Voltronic UPS Atlas is backed by a 2-year manufacturer warranty from Voltronic Power.

Customer reviews