Voltronic Power UPS ATLAS-LINE-INTERACTIVE
Discover the Voltronic Power Atlas Line Interactive UPS with 110/120 or 220/230/240 VAC voltage, ensuring reliable power protection.
Models and prices
- VOLTRONIC-ATLAS-LINE-INTERACTIVEAED 2,200incl. VAT
Technical Specifications
| Parameter | VOLTRONIC-ATLAS-LINE-INTERACTIVE |
|---|---|
| Output | |
| Voltage | 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC |
| AC Voltage Regulation (Batt. Mode) | ±10% |
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Transfer Time | 6ms typical, 10ms max |
| Waveform (Batt. Mode) | Pure Sinewave |
| Input | |
| Voltage Range | 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC |
| Frequency Range | 50/60 Hz ± 5Hz(Auto sensing) |
| Electrical Data | |
| Battery Type & Number | 12 V/7 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 1 / 12 V/7 Ah x 2 / 12 V/9 Ah x 2 |
| Battery | |
| Typical Recharge Time | 4-6 hours recover to 90% capacity |
| USB Charger | |
| USB Charger ports | Type A x 2 |
| Output Voltage | 5 V±5% |
| Load current | 2.1A(MAX) |
| Indicators | |
| LCD Display | Input/output voltage, input/output frequency, load in VA/Watts, battery capacity, estimated remaining runtime, site wiring fault indications. |
| Alarm | |
| Battery Mode | Sounding every 10 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding every 0.5 second |
| Fault | Continuously sounding |
| Management | |
| Optional USB Port | Supports Windows® Family, Linux and MAC |
| Certifications | |
| Compliance & Standards | 110/120VAC model: cTUVus (standard:UL 1778), FCC Part 15 Class B, ENERGY STAR (USA) / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 |
| Mechanical Data | |
| Dimension, D x W x H (mm) | 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 |
| Net Weight (kgs) | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
| Additional Specifications | |
| Weight | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
| Protection Features | |
| Full Protection | Overload, discharge, and overcharge protection |
| Operating Conditions | |
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB |
Figures are measured at the test conditions the manufacturer’s datasheet states. A dash means the manufacturer publishes no figure for that model.
Availability & grid compliance in the UAE
| Market | UAE |
|---|---|
| Grid authority / regulator | DEWA, ADDC, SEWA |
| Quotation currency | AED |
| Support hours timezone | Asia/Dubai |
| Main cities | Dubai, Abu Dhabi, Sharjah, Ajman, Ras Al Khaimah |
Figures on this page are the manufacturer's own, measured at the test conditions the datasheet states — they do not change by country. What changes is the approval that has to be met before the unit is energised: in the UAE that rests with the local authorities (DEWA, ADDC, SEWA). Confirm the grid code, import requirements and any local certification with them, or with us, before you order.
Key Features & Technical Highlights
- Excellent microprocessor control guarantees high: Excellent microprocessor control guarantees high reliability
- Boost and Buck AVR for: Boost and Buck AVR for voltage stabilization
- Auto restart while AC is: Auto restart while AC is recovering
- Pure sine wave
- Off-mode charging
- Cold-start function
- Built-in USB communication port and: Built-in USB communication port and RJ-45 phone protection
- Provides battery backup and surge: Provides battery backup and surge protected outputs
- Easy replacement battery compartment
- Hot-swappable battery design
- Optional Coax Surge Protection for: Optional Coax Surge Protection for TV antenna/network
- Optional 5V USB charger port: Optional 5V USB charger port for mobile devices
Frequently Asked Questions
What voltage does the Voltronic UPS Atlas operate on?
The Voltronic UPS Atlas has a nominal voltage of 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC and an operating voltage range of 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC / 81~134 VAC/89~145 VAC or 162~268 VAC/170~280 VAC/177~290 VAC.
What are the physical dimensions and weight of the Voltronic UPS Atlas?
The Voltronic UPS Atlas measures 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 and weighs 7.4 / 7.9 / 8.5 / 11.8 / 13.1.
What transfer time and output waveform does the Voltronic UPS Atlas provide?
The Voltronic UPS Atlas has a transfer time of 6ms typical, 10ms max and an output waveform of Pure Sinewave.
How does the Voltronic UPS Atlas regulate voltage?
The Voltronic UPS Atlas provides a voltage regulation of ±10%.
How loud is the Voltronic UPS Atlas during operation?
The Voltronic UPS Atlas has a noise level of Less than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB during operation.
What certifications does the Voltronic UPS Atlas have?
The Voltronic UPS Atlas is certified to cTUVus, FCC, ENERGY STAR, CE, EN 62040-1 and IEC 62040-1, meeting recognised international standards for safety and performance.
What warranty coverage is available for the Voltronic UPS Atlas?
The Voltronic UPS Atlas is backed by a 2-year manufacturer warranty from Voltronic Power.