Voltronic Power UPS Datasheet — VOLTRONIC-ATLAS-LINE-INTERACTIVE
Discover the Voltronic Power Atlas Line Interactive UPS with 110/120 or 220/230/240 VAC voltage, ensuring reliable power protection.
SKU: VOLTRONIC-ATLAS-LINE-INTERACTIVE | Last Updated: 2026-03-27
⚡Electrical Specifications
| Voltage | 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC / 110/120 VAC or 220/230/240 VAC |
| Voltage Range | 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC / 81~134VAC/89~145VAC or 162~268VAC/170~280VAC/177~290VAC |
| Frequency Range | 50/60 Hz ± 5Hz(Auto sensing) |
| AC Voltage Regulation (Batt. Mode) | ±10% |
| Frequency Range (Batt. Mode) | 60 Hz or 50 Hz ±1 Hz |
| Transfer Time | 6ms typical, 10ms max |
| Waveform (Batt. Mode) | Pure Sinewave |
| Battery Type & Number | 12 V/7 Ah x 1 / 12 V/9 Ah x 1 / 12 V/9 Ah x 1 / 12 V/7 Ah x 2 / 12 V/9 Ah x 2 |
| Typical Recharge Time | 4-6 hours recover to 90% capacity |
| USB Charger ports | Type A x 2 |
| Output Voltage | 5 V±5% |
| Load current | 2.1A(MAX) |
| LCD Display | Input/output voltage, input/output frequency, load in VA/Watts, battery capacity, estimated remaining runtime, site wiring fault indications. |
| Battery Mode | Sounding every 10 seconds |
| Low Battery | Sounding every second |
| Overload | Sounding every 0.5 second |
| Fault | Continuously sounding |
| Optional USB Port | Supports Windows® Family, Linux and MAC |
| Compliance & Standards | 110/120VAC model: cTUVus (standard:UL 1778), FCC Part 15 Class B, ENERGY STAR (USA) / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 / 220/230/240VAC model: CE, EN 62040-1:2008/A1:2013, IEC 62040-1:2008/A1:2013 |
🔧Mechanical Specifications
| Dimension, D x W x H (mm) | 288 x 99 x 280 / 288 x 99 x 280 / 288 x 99 x 280 / 410 x 99 x 280 / 410 x 99 x 280 |
| Net Weight (kgs) | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
| Weight | 7.4 / 7.9 / 8.5 / 11.8 / 13.1 |
🌡️Environmental Specifications
| Full Protection | Overload, discharge, and overcharge protection |
| Humidity | 0-90 % RH @ 0- 40°C (Non-condensing) |
| Noise Level | Less than 40dB / Less than 40dB / Less than 40dB / Less than 45dB / Less than 45dB |
📏Dimensions
Width99
Height280
Depth288
Weight7.4 / 7.9 / 8.5 / 11.8 / 13.1
✅Certifications
cTUVusFCCENERGY STARCEEN 62040-1IEC 62040-1