Voltronic Axpert IND 1.2KW Hybrid Solar Inverter
- Selectable Voltage Range:170-280 VAC (For Personal Computers)
- AC Voltage Regulation (Batt. Mode):230VAC ± 5%

The Axpert VM II Duplex 6K is an off-grid solar inverter rated Axpert VM II Duplex 6K.
In stock
The Axpert VM II Duplex 6K is an off-grid solar inverter rated Axpert VM II Duplex 6K. Every figure on this page is read from the manufacturer's manual for the Axpert VM II Duplex series.
Specifications last updated 18 August 2026
| Selectable Voltage Range | 170-280 VAC (For Computers) 90-280 VAC (For Home Appliances) |
|---|---|
| AC Voltage Regulation (Batt. Mode) | 230VAC ±5% |
| Surge Power | 12000VA |
| Waveform | Pure sine wave |
| Maximum PV Array Power | 6000W |
| Maximum PV Input Current | 27A |
| MPP Range @ Operating Voltage | 60-450 VDC |
| Maximum Solar Charge Current | 120A |
| Maximum AC Charge Current | 100A |
| Maximum Charge Current | 120A |
| Transfer Time | 10 ms (For Personal Computers), 20 ms (For Home Appliances) |
| Floating Charge Voltage | 54 VDC |
| Solar Charger Type | MPPT |
| Maximum PV Array Open Circuit Voltage | 500 VDC |
| Efficiency (Peak) | 93% |
| Net Weight (kgs) | 10.5 |
|---|---|
| Dimension, D x W x H (mm) | 107 x 322.6 x 420.3 |
| Humidity | 5% to 95% Relative Humidity (Non-condensing) |
|---|---|
| Operating Temperature | -10°C to 50°C |








Choose the right solar inverter for your UAE home. Compare grid-tie, hybrid, and off-grid inverters. DEWA Shams Dubai compliance and net metering explained.
Read: Solar Inverters for UAE Homes: Grid-Tie, Hybrid, and Off-Grid Options →Compare Voltronic Axpert and Must Solar off-grid inverters. Build quality, specifications, parallel capability, support network, and long-term value.
Read: Voltronic Axpert vs Must Solar Inverters: Which Platform Wins? →Set up WiFi monitoring for Voltronic Axpert, InfiniSolar, and UPS systems. App configuration, cloud dashboard, alerts, and troubleshooting tips.
Read: How to Monitor Voltronic Inverters and UPS via WiFi →The Axpert VM II Duplex 6K takes up to 6000W of PV array. The string has to stay below 500 VDC open-circuit — that ceiling is reached on a cold bright morning, not at noon. The tracker works over 60-450 VDC, so wire the modules to land inside that window.
Peak efficiency is 93%. Whatever is not converted leaves as heat, so the Axpert VM II Duplex 6K needs clear air around it and a mounting spot that is not the hottest wall in the building.
Up to 120A. Size the cable and the protection between the unit and the bank on that figure, not on the average you expect to see.